Design of Noninvasive Hemodynamic Monitoring Equipment Using Impedance Cardiography

被引:0
作者
Vu Duy Hai [1 ]
Lai Huu Phuong Trung [1 ]
Pham Manh Hung [1 ]
Dao Viet Hung [1 ]
Pham Phuc Ngoc [1 ]
Phan Dang Hung [1 ]
Chu Quang Dan [1 ]
Tran Quoc Vi [2 ]
机构
[1] Hanoi Univ Sci & Technol, Biomed Elect Ctr, Hanoi, Vietnam
[2] Vinh Phuc Gen Hosp, Vinh Phuc, Vietnam
来源
7TH INTERNATIONAL CONFERENCE ON THE DEVELOPMENT OF BIOMEDICAL ENGINEERING IN VIETNAM (BME7): TRANSLATIONAL HEALTH SCIENCE AND TECHNOLOGY FOR DEVELOPING COUNTRIES | 2020年 / 69卷
关键词
Noninvasive hemodynamic monitor; Impedance cardiography; Stroke volume; Cardiac output; Thoracic fluid content; Left ventricular ejection time;
D O I
10.1007/978-981-13-5859-3_1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Hemodynamic parameters play a very important role in supporting physicians to diagnose and treat cardiovascular diseases. This paper presents the results of the study on designing of noninvasive hemodynamic monitoring equipment using impedance cardiography (ICG). This is a measurement method that shows many advantages and is interested in the present. The equipment has ability of measurement and monitoring hemodynamic parameters include: heart rate HR; thoracic fluid content TFC; left ventricular ejection time LVET; stroke volume SV; cardiac output CO and ICG waveform. Results of measurement between the research equipment BK-NICO and the standard equipment of NICCOMO for 104 patients show that the hemodynamic parameters measured by the two equipments are quite small difference. Specifically, the average deviation of the parameters obtained, HR is 0.16 bpm, TFC is 0.73 1/k Omega, LVET is 5.95 ms, SV is 0.17 ml, CO is 0.01 lpm. With the results of the research, the device is fully capable of deploying the application into practice in the hospitals to replace the current invasive measurement method.
引用
收藏
页码:3 / 9
页数:7
相关论文
共 50 条
  • [31] Improvement of hemodynamic parameters in aortic stenosis patients with transcatheter valve replacement by using impedance cardiography
    Wan, Luqing
    Tang, Jianjun
    Xiao, Yanchao
    Li, Hui
    Peng, Zengjin
    Xu, Dan-Yan
    Shen, Li
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [32] Impedance cardiography as tool for continuous hemodynamic monitoring during cesarean section: randomized, prospective double blind study
    D'Ambrosio, Alessandro
    Cotoia, Antonella
    Beck, Renata
    Salatto, Potito
    Zibar, Lada
    Cinnella, Gilda
    BMC ANESTHESIOLOGY, 2018, 18
  • [33] Prognostic value of hemodynamic findings from impedance cardiography in hypertensive stroke
    Ramirez, MFL
    Tibayan, RT
    Marinas, CE
    Yamamoto, ME
    Caguioa, EVS
    AMERICAN JOURNAL OF HYPERTENSION, 2005, 18 (02) : 65S - 72S
  • [34] Hemodynamic response to exercise as measured by the solar IKG Impedance Cardiography Module and correlation with metabolic variables
    Ziegeler S.
    Grundmann U.
    Fuerst O.
    Raddatz A.
    Kreuer S.
    Journal of Clinical Monitoring and Computing, 2007, 21 (1) : 13 - 20
  • [35] Noninvasive monitoring of cardiac output during exercise by inductance cardiography
    Kaplan, V
    Bucklar, GB
    Bloch, KE
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (05) : 747 - 752
  • [36] Noninvasive investigation of the cardiodynamic response to 6MWT in people after stroke using impedance cardiography
    Liu, Fang
    Jones, Alice Y. M.
    Tsang, Raymond C. C.
    Wang, Yao
    Zhou, Jing
    Zhou, Mingchao
    Wang, Yulong
    PLOS ONE, 2020, 15 (06):
  • [37] Detection of valvular heart diseases using impedance cardiography ICG
    Chabchoub, Souhir
    Mansouri, Sofienne
    Ben Salah, Ridha
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2018, 38 (02) : 251 - 261
  • [38] Determination of Cardiac Output in Pulmonary Hypertension Using Impedance Cardiography
    Dupuis, Marion
    Noel-Savina, Elise
    Prevot, Gregoire
    Tetu, Laurent
    Pillard, Fabien
    Riviere, Daniel
    Didier, Alain
    RESPIRATION, 2018, 96 (06) : 500 - 506
  • [39] Impedance Cardiography as a Noninvasive Technique for Atrioventricular Interval Optimization in Cardiac Resynchronization Therapy
    Martin U. Braun
    Andreas Schnabel
    Thomas Rauwolf
    Matthias Schulze
    Ruth H. Strasser
    Journal of Interventional Cardiac Electrophysiology, 2005, 13 : 223 - 229
  • [40] Impedance cardiography as a noninvasive technique for atrioventricular interval optimization in cardiac resynchronization therapy
    Braun, MU
    Schnabel, A
    Rauwolf, T
    Schulze, M
    Strasser, RH
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2005, 13 (03) : 223 - 229