Measurement of the x-ray mass attenuation coefficient and the imaginary part of the form factor of silicon using synchrotron radiation

被引:43
|
作者
Tran, CQ [1 ]
Chantler, CT
Barnea, Z
Paterson, D
Cookson, DJ
机构
[1] Univ Melbourne, Sch Phys, Parkville, Vic 3010, Australia
[2] Argonne Natl Lab, SRI CAT, APS, Argonne, IL 60439 USA
[3] Australian Nucl Sci & Technol Org, Menai, NSW 2234, Australia
[4] Argonne Natl Lab, Chem Mat CARS CAT, Argonne, IL 60439 USA
来源
PHYSICAL REVIEW A | 2003年 / 67卷 / 04期
关键词
D O I
10.1103/PhysRevA.67.042716
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We used the x-ray extended-range technique to measure the x-ray mass attenuation coefficients of silicon with an accuracy between 0.27% and 0.5% in the 5 keV-20 keV energy range. Subtraction of the x-ray scattering contribution enabled us to derive the corresponding x-ray photoelectric absorption coefficients and determine the absolute value of the imaginary part of the atomic form factor of silicon. Discrepancies between the experimental values of the mass attenuation coefficients and theoretically calculated values are discussed. New approaches to the theoretical calculation will be required to match the precision and accuracy of the experimental results.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Measurements of the x-ray mass-attenuation coefficient and imaginary component of the form factor of copper
    Glover, J. L.
    Chantler, C. T.
    Barnea, Z.
    Rae, N. A.
    Tran, C. Q.
    Creagh, D. C.
    Paterson, D.
    Dhal, B. B.
    PHYSICAL REVIEW A, 2008, 78 (05):
  • [2] Measurement of the x-ray mass attenuation coefficient of copper using 8.85-20 keV synchrotron radiation
    Chantler, CT
    Tran, CQ
    Barnea, Z
    Paterson, D
    Cookson, DJ
    Balaic, DX
    PHYSICAL REVIEW A, 2001, 64 (06): : 15
  • [3] Measurement of X-ray mass attenuation coefficient of nickel around the K-edge using synchrotron radiation based X-ray absorption study
    Roy, Bunty Rani
    Rajput, Parasmani
    Jha, S. N.
    Rao, A. S. Nageswara
    RADIATION PHYSICS AND CHEMISTRY, 2015, 114 : 38 - 42
  • [4] X-RAY EXTENDED-RANGE TECHNIQUE FOR PRECISION MEASUREMENT OF THE X-RAY MASS ATTENUATION COEFFICIENT AND IM(F) FOR MOLYBDENUM USING SYNCHROTRON RADIATION
    de Jonge, M. D.
    Tran, C. Q.
    Barnea, Z.
    Dhal, B. B.
    Cookson, D. J.
    Chantler, C. T.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2002, 58 : C82 - C82
  • [5] X-ray extended-range technique for precision measurement of the X-ray mass attenuation coefficient and Im(f) for copper using synchrotron radiation
    Chantler, CT
    Tran, CQ
    Paterson, D
    Cookson, D
    Barnea, Z
    PHYSICS LETTERS A, 2001, 286 (05) : 338 - 346
  • [6] Measurement of the x-ray mass attenuation coefficient and determination of the imaginary component of the atomic form factor of molybdenum over the 13.5-41.5-keV energy range
    de Jonge, MD
    Tran, CQ
    Chantler, CT
    Barnea, Z
    Dhal, BB
    Cookson, DJ
    Lee, WK
    Mashayekhi, A
    PHYSICAL REVIEW A, 2005, 71 (03):
  • [7] X-ray mass attenuation coefficient of silicon: Theory versus experiment
    Tran, CQ
    Chantler, CT
    Barnea, Z
    PHYSICAL REVIEW LETTERS, 2003, 90 (25) : 257401 - 257401
  • [8] Measurement of the x-ray mass attenuation coefficient of silver using the x-ray-extended range technique
    Tran, CQ
    Chantler, CT
    Barnea, Z
    de Jonge, MD
    Dhal, BB
    Chung, CTY
    Paterson, D
    Wang, J
    JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 2005, 38 (01) : 89 - 107
  • [9] Measurement of the x-ray mass energy-absorption coefficient of air using 3 keV to 10 keV synchrotron radiation
    Bueermann, L.
    Grosswendt, B.
    Kramer, H-M
    Selbach, H-J
    Gerlach, M.
    Hoffmann, M.
    Krumrey, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (20): : 5125 - 5150
  • [10] MEASUREMENT OF SYNCHROTRON RADIATION IN X-RAY REGION
    BATHOW, G
    FREYTAG, E
    HAENSEL, R
    JOURNAL OF APPLIED PHYSICS, 1966, 37 (09) : 3449 - &