Marginal and Internal Precision of Zirconia Four-Unit Fixed Partial Denture Frameworks Produced Using Four Milling Systems

被引:2
作者
Lehmann, Karl Martin [1 ]
Weyhrauch, Michael [1 ]
Bjelopavlovic, Monika [1 ]
Scheller, Herbert [1 ]
Staedt, Henning [2 ]
Ottl, Peter [2 ,3 ]
Kaemmerer, Peer W. [4 ]
Wentaschek, Stefan [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Dept Prosthodont & Mat Sci, Univ Med Ctr, Augustuspl 2, D-55131 Mainz, Germany
[2] Univ Rostock, Dept Prosthodont & Mat Sci, Strempelstr 13, D-18057 Rostock, Germany
[3] Univ Rostock, Dept Life Light & Matter, Albert Einstein Str 25, D-18059 Rostock, Germany
[4] Johannes Gutenberg Univ Mainz, Dept Oral & Maxillofacial Surg, Univ Med Ctr, Augustuspl 2, D-55131 Mainz, Germany
关键词
marginal fit; internal fit; zirconia; FPD; CAD; CAM; CLINICAL FIT; ADAPTATION; CROWNS; COPINGS;
D O I
10.3390/ma14102663
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Background: CAD/CAM systems enable the production of fixed partial dentures with small and reproducible internal and marginal gaps. Purpose: The purpose of this study was to evaluate the reproducibility of the marginal and internal adaptations of four-unit fixed partial denture frameworks produced using four CAD/CAM systems. Materials and Methods: Prepared dies of a master model that simulated the loss of the first left molar were measured. Fifteen frameworks were manufactured using four CAD/CAM systems (A-D). The internal fit was determined by the replica technique, and the marginal gap was determined by microscopy. ANOVA was carried out to detect significant differences, and the Bonferroni adjustment was performed. The global level of significance was set at 5%. Results: The mean gap size ranged from 84 to 132 mu m (SD 43-71 mu m). The CAD/CAM systems showed significant variance (p < 0.001), and system A (VHF) showed the smallest gaps. The smallest gaps for each system were in the molar part and in the marginal region of the frameworks (p < 0.001). Conclusions: The CAD/CAM systems showed significantly different gap sizes, particularly between premolars and molars and among the marginal, axial and occlusal regions. All of the systems are suitable for clinical application.
引用
收藏
页数:8
相关论文
共 40 条
  • [31] Moermann WH, 2006, J AM DENT ASSOC, V137, p7S
  • [32] MORMANN W H, 1991, Acta Stomatologica Croatica, V25, P3
  • [33] Zirconia as a ceramic biomaterial
    Piconi, C
    Maccauro, G
    [J]. BIOMATERIALS, 1999, 20 (01) : 1 - 25
  • [34] Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems
    Reich, S
    Wichmann, M
    Nkenke, E
    Proeschel, P
    [J]. EUROPEAN JOURNAL OF ORAL SCIENCES, 2005, 113 (02) : 174 - 179
  • [35] Multifactorial analysis of the impact of different manufacturing processes on the marginal fit of zirconia copings
    Rinke, Sven
    Fornefett, Daniel
    Gersdorff, Nikolaus
    Lange, Katharina
    Roediger, Matthias
    [J]. DENTAL MATERIALS JOURNAL, 2012, 31 (04) : 601 - 609
  • [36] Influence of Sequential CAD/CAM Milling on the Fitting Accuracy of Titanium Three-Unit Fixed Dental Prostheses
    Song, Doo-Bin
    Han, Man-So
    Kim, Si-Chul
    Ahn, Junyong
    Im, Yong-Woon
    Lee, Hae-Hyoung
    [J]. MATERIALS, 2021, 14 (06)
  • [37] Sulaiman F, 1997, INT J PROSTHODONT, V10, P478
  • [38] Systematic Review of Clinical Applications of CAD/CAM Technology for Craniofacial Implants Placement and Manufacturing of Nasal Prostheses
    Tanveer, Waqas
    Ridwan-Pramana, Angela
    Molinero-Mourelle, Pedro
    Koolstra, Jan Harm
    Forouzanfar, Tymour
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (07)
  • [39] Vigolo Paolo, 2008, J Prosthodont, V17, P621, DOI 10.1111/j.1532-849X.2008.00366.x
  • [40] MARGINAL ADAPTATION OF CASTABLE CERAMIC CROWNS
    WEAVER, JD
    JOHNSON, GH
    BALES, DJ
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1991, 66 (06) : 747 - 753