Using Experimental Measurements of the Concentrations of Carbon Dioxide for Determining the Intensity of Ventilation in the Rooms

被引:3
作者
Kapalo, Peter [1 ]
Vilcekova, Silvia [2 ]
Voznyak, Orest [3 ]
机构
[1] Tech Univ Kosice, Fac Civil Engn, Inst Architectural Engn, Vysokoskolska 4, Kosice 04200, Slovakia
[2] Tech Univ Kosice, Fac Civil Engn, lnst Environm Engn, Vysokoskolska 4, Kosice 04200, Slovakia
[3] Natl Univ Lviv Polytech, UA-79013 Lvov, Ukraine
来源
PRES 2014, 17TH CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, PTS 1-3 | 2014年 / 39卷
关键词
Air conditioning - Carbon dioxide - Indoor air pollution - Waste heat - Energy conservation - Operating costs - Air quality;
D O I
10.3303/CET1439299
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Considering the fact that in operating costs of the new building the important place take expenses on heating, mainly, on air heating in systems of ventilation, the measures directed on optimization of the intensity of ventilation at maintaining comfort of consumers, are of high importance and have national character. To reduce electricity consumption it is possible to use air-conditioning equipment providing heat recovery from exhaust air. When choosing the ventilating equipment it is necessary to consider the correct boundary conditions that the ventilating equipment wasn't the overestimated or underestimated power with the aim of optimizing investment and operating costs of ventilation equipment in compliance with sanitary requirements with regard to air quality in the internal environment of buildings. This paper is aimed to develop a methodology for determining the intensity of ventilation of indoor premises based on the experimental measurements of the concentration of carbon dioxide (CO2). Using experimental measurements and the knowledge gained in the study of this issue, in the work the method for intensity ventilation determining of the indoor premises was developed on the basis of the measured values of carbon dioxide which was verified also by another experimental measurements. The resulting values of ventilation intensity rate obtained by calculation from the measured values of carbon dioxide were compared with the results of calculations executed according to the laws and standards, current in Slovakia. Based on comparison of the results one of the methods for calculation of the ventilation intensity was developed that is valid in Slovakia, the results of which were close to the results obtained by the method of determining the intensity of ventilation rate in the room on the basis of the measured values of carbon dioxide. The above mentioned method is determined by the method of calculating intensity of ventilation rate in the rooms intended for offices.
引用
收藏
页码:1789 / +
页数:2
相关论文
共 4 条
[1]  
[Anonymous], 2012, 7305402 STN
[2]  
[Anonymous], 2005, 13779 STN EN
[3]  
[Anonymous], 2007, 15251 STN EN
[4]  
Persily A., 2005, Indoor Air, Ed, V15, P24