Automated detection of lung nodules in CT scans:: Effect of image reconstruction algorithm

被引:51
|
作者
Armato, SG [1 ]
Altman, MB [1 ]
La Rivière, PJ [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
关键词
computer-aided diagnosis (CAD); lung nodules; computed tomography; image processing; image reconstruction;
D O I
10.1118/1.1544679
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have investigated the effect of computed tomography (CT) image reconstruction algorithm on the performance of our automated lung nodule detection method. Commercial CT scanners offer a choice of several algorithms for the reconstruction of projection data into transaxial images. Different algorithms produce images with substantially different properties that are apparent not only quantitatively, but also through visual assessment. During some clinical thoracic CT examinations, patient scans are reconstructed with multiple reconstruction algorithms. Thirty-eight such cases were collected to form two databases: one with patient projection data reconstructed with the "standard" reconstruction algorithm and the other with the same patient projection data reconstructed with the "lung" reconstruction algorithm. The automated nodule detection method was applied to both databases. This method is based on gray-level-thresholding techniques to segment the lung regions from each CT section to create a segmented lung volume. Further gray-level-thresholding techniques are applied within the segmented lung volume to identify a set of lung nodule candidates. Rule-based and linear discriminant classifiers are used to differentiate between lung nodule candidates that correspond to actual nodules and those that correspond to non-nodules. The automated method that was applied to both databases was exactly the same, except that the classifiers were calibrated separately for each database. For comparison, the classifier then was trained on one database and tested independently on the other database. When applied to the databases in this manner, the automated method demonstrated overall a similar level of performance, indicating an encouraging degree of robustness. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:461 / 472
页数:12
相关论文
共 50 条
  • [11] Effect of CAD on radiologists' detection of lung nodules on thoracic CT scans: Observer performance study
    Sahiner, Berkman
    Hadjiiski, Lubomir M.
    Chan, Heang-Ping
    Shi, Jiazheng
    Cascade, Philip N.
    Kazerooni, Ella A.
    Zhou, Chuan
    Wei, Jun
    Chughtai, Aamer R.
    Poopat, Chad
    Song, Thomas
    Nojkova, Jadranka S.
    Frank, Luba
    Attili, Anil
    MEDICAL IMAGING 2007: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2007, 6515
  • [12] Automated CAD for Lung Nodule Detection using CT Scans
    Gomathi, M.
    Thangaraj, P.
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON DATA STORAGE AND DATA ENGINEERING (DSDE 2010), 2010, : 150 - 153
  • [13] Automated detection of lung nodules in CT images using shape-based genetic algorithm
    Dehmeshki, Jamshid
    Ye, Xujiong
    Lin, Xinyu
    Valdivieso, Manho
    Amin, Hamdan
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2007, 31 (06) : 408 - 417
  • [14] Automated detection of nodules in the CT lung images using multi-modal genetic algorithm
    Dehmeshki, J
    Siddique, M
    Lin, XY
    Roddie, M
    Costello, J
    ISPA 2003: PROCEEDINGS OF THE 3RD INTERNATIONAL SYMPOSIUM ON IMAGE AND SIGNAL PROCESSING AND ANALYSIS, PTS 1 AND 2, 2003, : 393 - 398
  • [15] A hybrid approach for automated detection of lung nodules in CT images
    Dehmeshki, J.
    Ye, X.
    Casique, M. V.
    Lin, X. Y.
    2006 3RD IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1-3, 2006, : 506 - +
  • [16] Automated Segmentation Refinement of Small Lung Nodules in CT Scans by Local Shape Analysis
    Diciotti, Stefano
    Lombardo, Simone
    Falchini, Massimo
    Picozzi, Giulia
    Mascalchi, Mario
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (12) : 3418 - 3428
  • [17] Automated detection of lung nodules in multidetector CT: Influence of different reconstruction protocols on performance of a software prototype
    Gurung, J
    Maataoui, A
    Khan, M
    Wetter, A
    Harth, M
    Jacobi, V
    Vogl, TJ
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2006, 178 (01): : 71 - 77
  • [18] Ground Glass Opacity (GGO) Nodules Detection from Lung CT Scans
    Paing, May Phu
    Choomchuay, Somsak
    2017 INTERNATIONAL SYMPOSIUM ON ELECTRONICS AND SMART DEVICES (ISESD), 2017, : 230 - 235
  • [19] A computer-aided diagnostic method for the detection of lung nodules in CT scans
    Armato, SG
    Engelmann, RM
    Giger, ML
    Doi, K
    MacMahon, H
    RADIOLOGY, 2000, 217 : 243 - 243
  • [20] Update on the development of an automated lung nodule detection method for CT scans
    Armato, SG