Biomechanical design of Less Invasive Stabilization System femoral plates: Computational evaluation of the fracture environment

被引:8
|
作者
Reina-Romo, Esther [1 ]
Giraldez-Sanchez, M. A. [2 ]
Mora-Macias, J. [1 ]
Cano-Luis, P. [2 ]
Dominguez, Jaime [1 ]
机构
[1] Univ Seville, Dept Mech Engn, Seville 41092, Spain
[2] Hosp Univ Virgen del Rocio, Dept Traumatol, Seville, Spain
关键词
Less Invasive Stabilization System; femoral plate; biomechanics; finite element; femoral fracture; TROCHANTERIC GAMMA-NAIL; FINITE-ELEMENT-ANALYSIS; LOCKING PLATE; MECHANICAL CONDITIONS; KNEE ARTHROPLASTY; INTERNAL-FIXATION; FEMUR FRACTURES; SCREW PLACEMENT; LISS; BONE;
D O I
10.1177/0954411914554634
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Less Invasive Stabilization System femoral plates are currently accepted as a suitable fixation technique for supra-intercondylar femoral fractures. However, general agreement does not exist regarding the optimum design of this fixator type. Therefore, the aim of this article is to reduce the intrinsic Less Invasive Stabilization System complications by clarifying, from a biomechanical point of view, how the number of screws, the screw connection type (unicortical or bicortical), or the structured position of the screws can influence the outcome of the fracture site. These studies include a specific finite element analysis that determines how several biomechanical variables, such as the movement at the fracture site, are influenced by the preconditions of bone healing. The results of this study show that the screw type affects the mechanical stabilization of the femur to a greater extent than the material type of the Less Invasive Stabilization System femoral plates. The most significant differences among all the analyzed configurations are observed in the shear interfragmentary strain between screw types. Values are approximately 50% higher with unicortical screws than with bicortical ones.
引用
收藏
页码:1043 / 1052
页数:10
相关论文
共 50 条
  • [41] Biomechanical Evaluation of Cannulated Screw Optimization for Stabilization of Pauwels Type Femoral Neck Fractures
    Verim, Ozgur
    APPLIED SCIENCES-BASEL, 2024, 14 (07):
  • [42] Biomechanical Evaluation of the Fixation Methods for Transcondylar Fracture of the Humerus: ONI Plate Versus Conventional Plates and Screws
    Shimamura, Yasunori
    Nishida, Keiichiro
    Imatani, Junya
    Noda, Tomoyuki
    Hashizume, Hiroyuki
    Ohtsuka, Aiji
    Ozaki, Toshifumi
    ACTA MEDICA OKAYAMA, 2010, 64 (02) : 115 - 120
  • [43] Minimally invasive stabilization of distal humerus fractures: A pilot study with biomechanical evaluation
    Reising, K.
    Konstantinidis, L.
    Helwig, P.
    Wagner, F. C. L.
    Suedkamp, N. P.
    Strohm, P. C.
    TECHNOLOGY AND HEALTH CARE, 2014, 22 (06) : 909 - 913
  • [44] Biomechanical testing of a novel, minimally invasive rib fracture plating system
    Sales, J. Rafe
    Ellis, Thomas J.
    Gillard, Joel
    Liu, Qi
    Chen, Joyce C.
    Ham, Bruce
    Mayberry, John C.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2008, 64 (05): : 1270 - 1274
  • [45] Treatment of complicated proximal segmental tibia fractures with the less invasive stabilization locking plate system
    Beck, M.
    Gradl, G.
    Gierer, P.
    Rotter, R.
    Witt, M.
    Mittlmeier, T.
    UNFALLCHIRURG, 2008, 111 (07): : 493 - 498
  • [46] Combination of modified free vascularized fibular grafting and reverse Less Invasive Stabilization System (LISS) for the management of femoral neck nonunion in patients thirty years of age or younger
    Lin, Sen
    Zhang, Chang-qing
    Jin, Dong-xu
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (08): : 1551 - 1556
  • [47] Versorgung der komplikationsbelasteten proximalen Tibia-Etagenfraktur mit dem winkelstabilen Less-invasive-stabilization-SystemTreatment of complicated proximal segmental tibia fractures with the less invasive stabilization locking plate system
    M. Beck
    G. Gradl
    P. Gierer
    R. Rotter
    M. Witt
    T. Mittlmeier
    Der Unfallchirurg, 2008, 111 (7):
  • [48] Biomechanical rationale and evaluation of an implant system for rib fracture fixation
    Bottlang, M.
    Walleser, S.
    Noll, M.
    Honold, S.
    Madey, S. M.
    Fitzpatrick, D.
    Long, W. B.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2010, 36 (05) : 417 - 426
  • [49] Patient-Specific Design and Biomechanical Evaluation of a Novel Bipolar Femoral Hemi-Knee Prosthesis
    Qin Lian
    Dichen Li
    Zhongmin Jin
    Zhen Wang
    Yuhan Sun
    Journal of Bionic Engineering, 2014, 11 : 259 - 267
  • [50] Patient-Specific Design and Biomechanical Evaluation of a Novel Bipolar Femoral Hemi-Knee Prosthesis
    Lian, Qin
    Li, Dichen
    Jin, Zhongmin
    Wang, Zhen
    Sun, Yuhan
    JOURNAL OF BIONIC ENGINEERING, 2014, 11 (02) : 259 - 267