Biomechanical design of Less Invasive Stabilization System femoral plates: Computational evaluation of the fracture environment

被引:8
|
作者
Reina-Romo, Esther [1 ]
Giraldez-Sanchez, M. A. [2 ]
Mora-Macias, J. [1 ]
Cano-Luis, P. [2 ]
Dominguez, Jaime [1 ]
机构
[1] Univ Seville, Dept Mech Engn, Seville 41092, Spain
[2] Hosp Univ Virgen del Rocio, Dept Traumatol, Seville, Spain
关键词
Less Invasive Stabilization System; femoral plate; biomechanics; finite element; femoral fracture; TROCHANTERIC GAMMA-NAIL; FINITE-ELEMENT-ANALYSIS; LOCKING PLATE; MECHANICAL CONDITIONS; KNEE ARTHROPLASTY; INTERNAL-FIXATION; FEMUR FRACTURES; SCREW PLACEMENT; LISS; BONE;
D O I
10.1177/0954411914554634
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Less Invasive Stabilization System femoral plates are currently accepted as a suitable fixation technique for supra-intercondylar femoral fractures. However, general agreement does not exist regarding the optimum design of this fixator type. Therefore, the aim of this article is to reduce the intrinsic Less Invasive Stabilization System complications by clarifying, from a biomechanical point of view, how the number of screws, the screw connection type (unicortical or bicortical), or the structured position of the screws can influence the outcome of the fracture site. These studies include a specific finite element analysis that determines how several biomechanical variables, such as the movement at the fracture site, are influenced by the preconditions of bone healing. The results of this study show that the screw type affects the mechanical stabilization of the femur to a greater extent than the material type of the Less Invasive Stabilization System femoral plates. The most significant differences among all the analyzed configurations are observed in the shear interfragmentary strain between screw types. Values are approximately 50% higher with unicortical screws than with bicortical ones.
引用
收藏
页码:1043 / 1052
页数:10
相关论文
共 50 条
  • [31] Thoracolumbar fracture stabilization: comparative biomechanical evaluation of a new video-assisted implantable system
    M. Schultheiss
    E. Hartwig
    L. Kinzl
    L. Claes
    H.-J. Wilke
    European Spine Journal, 2004, 13 : 93 - 100
  • [32] Less invasive stabilization of complex tibial plateau fractures -: A biomechanical evaluation of a unilateral locked screw plate and double plating
    Gösling, T
    Schandelmaier, P
    Marti, A
    Hufner, T
    Partenheimer, A
    Krettek, C
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (08) : 546 - 551
  • [33] Are Locking Constructs in Distal Femoral Fractures Always Best? A Prospective Multicenter Randomized Controlled Trial Comparing the Less Invasive Stabilization System With the Minimally Invasive Dynamic Condylar Screw System
    Leighton, R. K.
    Schemitsch, E. H.
    Stephen, D. J. G.
    McCormack, R.
    Sanders, D.
    O'Brien, P.
    Buckley, R.
    Trask, K.
    Mckee, M. D.
    Schemitsch, E. H.
    Kreder, H. J.
    McCormack, R.
    Buckley, R.
    Robinson, J. de Dios
    Coles, C.
    Stephen, D. J. G.
    Buckley, R.
    Oxner, W.
    Amirault, J. D.
    Glazebrook, M.
    Waddell, J. P.
    Whelan, D.
    Hall, J. A.
    Wild, L. M.
    Vicente, M.
    Axelrod, T. A.
    Jenkinson, R.
    Stone, T. B.
    Panagiotopoulos, K.
    Piper, M.
    Zomar, M.
    MacLeod, M.
    Tieszer, C.
    Guy, P.
    Blachut, P.
    Broekhuyse, H.
    Johal, R.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (01) : E1 - E6
  • [34] A New System for Periprosthetic Fracture Stabilization-A Biomechanical Comparison
    Rau, Daniel
    Russow, Gabriele
    Heyland, Mark
    Wulsten, Dag
    Koesters, Clemens
    Schmoelz, Werner
    Maerdian, Sven
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (03)
  • [35] Biomechanical evaluation of reconstruction plates with locking, nonlocking, and hybrid screws configurations in calcaneal fracture: a finite element model study
    Chen, Ching-Hsuan
    Hung, Chinghua
    Hsu, Yu-Chun
    Chen, Chen-Sheng
    Chiang, Chao-Ching
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2017, 55 (10) : 1799 - 1807
  • [36] Biomechanical evaluation of reconstruction plates with locking, nonlocking, and hybrid screws configurations in calcaneal fracture: a finite element model study
    Ching-Hsuan Chen
    Chinghua Hung
    Yu-Chun Hsu
    Chen-Sheng Chen
    Chao-Ching Chiang
    Medical & Biological Engineering & Computing, 2017, 55 : 1799 - 1807
  • [37] Impact of femoral neck system removal after femoral neck fracture healing on biomechanical stability and screw stripping risk
    Lee, Se-Won
    Pak, Jeongah
    Lim, Dohyung
    BIOMEDICAL ENGINEERING LETTERS, 2025, 15 (02) : 349 - 355
  • [38] Less invasive stabilization system for the management of proximal tibia fractures
    Devkota P.
    Manandhar H.K.
    Khadka P.B.
    Mainali L.P.
    Khan J.A.
    Acharya B.M.
    Pradhan N.S.
    Shrestha S.K.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (6) : 993 - 998
  • [39] The development of the distal femur Less Invasive Stabilization System (LISS)
    Frigg, R
    Appenzeller, A
    Christensen, R
    Frenk, A
    Gilbert, S
    Schavan, R
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2001, 32 : 24 - 31
  • [40] Metal and composite bone plates for B1 periprosthetic femoral fracture in healthy and osteoporotic condition: A comparative biomechanical study
    Dhason, Raja
    Roy, Sandipan
    Datta, Shubhabrata
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2022, 45 (08) : 704 - 714