Biomechanical design of Less Invasive Stabilization System femoral plates: Computational evaluation of the fracture environment

被引:8
|
作者
Reina-Romo, Esther [1 ]
Giraldez-Sanchez, M. A. [2 ]
Mora-Macias, J. [1 ]
Cano-Luis, P. [2 ]
Dominguez, Jaime [1 ]
机构
[1] Univ Seville, Dept Mech Engn, Seville 41092, Spain
[2] Hosp Univ Virgen del Rocio, Dept Traumatol, Seville, Spain
关键词
Less Invasive Stabilization System; femoral plate; biomechanics; finite element; femoral fracture; TROCHANTERIC GAMMA-NAIL; FINITE-ELEMENT-ANALYSIS; LOCKING PLATE; MECHANICAL CONDITIONS; KNEE ARTHROPLASTY; INTERNAL-FIXATION; FEMUR FRACTURES; SCREW PLACEMENT; LISS; BONE;
D O I
10.1177/0954411914554634
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Less Invasive Stabilization System femoral plates are currently accepted as a suitable fixation technique for supra-intercondylar femoral fractures. However, general agreement does not exist regarding the optimum design of this fixator type. Therefore, the aim of this article is to reduce the intrinsic Less Invasive Stabilization System complications by clarifying, from a biomechanical point of view, how the number of screws, the screw connection type (unicortical or bicortical), or the structured position of the screws can influence the outcome of the fracture site. These studies include a specific finite element analysis that determines how several biomechanical variables, such as the movement at the fracture site, are influenced by the preconditions of bone healing. The results of this study show that the screw type affects the mechanical stabilization of the femur to a greater extent than the material type of the Less Invasive Stabilization System femoral plates. The most significant differences among all the analyzed configurations are observed in the shear interfragmentary strain between screw types. Values are approximately 50% higher with unicortical screws than with bicortical ones.
引用
收藏
页码:1043 / 1052
页数:10
相关论文
共 50 条
  • [21] Computational evaluation of the biomechanical effects of position changes in the femoral neck system on Pauwels type III femoral neck fractures: an in silico study
    Zhang, Xiang
    Zhang, Shenghang
    Zhong, Zhou
    Zhang, Wen
    Xiong, Zhongwei
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2025, 13
  • [22] Biomechanical evaluation of the Less Invasive Stabilization System, angled blade plate, and retrograde intramedullary nail for the internal fixation of distal femur fractures
    Zlowodzki, M
    Williamson, S
    Cole, PA
    Zardiackas, LD
    Kregor, PJ
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (08) : 494 - 502
  • [23] Biomechanical Analysis of the Less Invasive Stabilization System for Mechanically Unstable Fractures of the Distal Femur: Comparison of Titanium Versus Stainless Steel and Bicortical Versus Unicortical Fixation
    Beingessner, Daphne
    Moon, Edward
    Barei, David
    Morshed, Saam
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 71 (03): : 620 - 624
  • [24] Reverse polyaxial less invasive stabilization systems for treatment of femoral intertrochanteric fractures of the distal femur
    Shen, Longxiang
    Li, Xiaolin
    Wang, Tao
    Luo, Congfeng
    Zeng, Bingfang
    Ding, Jian
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (11) : 1531 - 1537
  • [25] Less Invasive Stabilization System (LISS) Versus Proximal Femoral Nail Anti-rotation (PFNA) in Treating Proximal Femoral Fractures: A Prospective Randomized Study
    Zhou, Fang
    Zhang, Zhi Shan
    Yang, Huan
    Tian, Yun
    Ji, Hong Quan
    Guo, Yan
    Lv, Yang
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (03) : 155 - 162
  • [26] Fixation of Distal Femoral Fractures With the Less Invasive Stabilization System: A Minimally Invasive Treatment With Locked Fixed-Angle Screws
    Kolb, Werner
    Guhlmann, Hanno
    Windisch, Christoph
    Marx, Frank
    Kolb, Klaus
    Koller, Heiko
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2008, 65 (06): : 1425 - 1434
  • [27] Treatment of Periarticular Fractures of the Knee Using the Less Invasive Stabilization System: A Retrospective Clinical Trial
    Ermutlu, Cenk
    Goksel, Ferdi
    Eken, Gokay
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (04)
  • [28] Proximal Femoral Nail Antirotation Versus Reverse Less Invasive Stabilization System-distal Femur for Treating Proximal Femoral Fractures A Meta-analysis
    Jiang, Xuan
    Wang, Ying
    Ma, XinLong
    Ma, JianXiong
    Wang, Chen
    Zhang, ChengBao
    Han, Zhe
    Sun, Lei
    Lu, Bin
    MEDICINE, 2016, 95 (14)
  • [29] Treatment of periprosthetic femoral fractures with two different minimal invasive angle-stable plates: Biomechanical comparison studies on cadaveric bones
    Konstantinidis, L.
    Hauschild, O.
    Beckmann, N. A.
    Hirschmueller, A.
    Suedkamp, N. P.
    Helwig, P.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (12): : 1256 - 1261
  • [30] Thoracolumbar fracture stabilization: comparative biomechanical evaluation of a new video-assisted implantable system
    Schultheiss, M
    Hartwig, E
    Kinzl, L
    Claes, L
    Wilke, HJ
    EUROPEAN SPINE JOURNAL, 2004, 13 (02) : 93 - 100