Comparison between the Transcutaneous and Total Serum Bilirubin Measurement in Malay Neonates with Neonatal Jaundice

被引:12
|
作者
Mohamed, Mazrah [1 ]
Ibrahim, Nor Rosidah [1 ,2 ]
Ramli, Noraida [1 ,2 ]
Majid, Noorizan Abdul [1 ,2 ]
Yacob, Najib Majdi [3 ]
Nasir, Ariffin [1 ,2 ]
机构
[1] Univ Sains Malaysia, Sch Med Sci, Dept Paediat, Kubang Kerian 16150, Kelantan, Malaysia
[2] Univ Sains Malaysia, Hosp Univ Sains Malaysia, Kubang Kerian, Kelantan, Malaysia
[3] Univ Sains Malaysia, Sch Med Sci, Biostat & Res Methodol Unit, Kubang Kerian, Kelantan, Malaysia
来源
MALAYSIAN JOURNAL OF MEDICAL SCIENCES | 2022年 / 29卷 / 01期
关键词
transcutaneous bilirubin; total serum bilirubin; JM-105; bilirubinometer; neonatal jaundice; TERM; HYPERBILIRUBINEMIA; IMPLEMENTATION; NEWBORNS; ACCURACY; DEVICE;
D O I
10.21315/mjms2022.29.1.5
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: This study aims to investigate the reliability of the Drager Jaundice Meter JM-105 for the screening of neonatal jaundice in Malay neonates. Methods: A cross-sectional study was conducted in a university hospital involving 130 jaundiced neonates requiring serum bilirubin determination from day 2 to day 7 of life. Results: The mean total serum bilirubin (TSB) was 232 mu mol/L, whereas the mean transcutaneous bilirubin (TcB) measured at the forehead and sternum were 222 mu mol/L and 223 mu mol/L, respectively. Further, TcB underestimates TSB with a mean difference of 10.10 mu mol/L at the forehead and 9.27 mu mol/L at the sternum. A positive linear relationship was observed between TSB with TcB forehead (r = 0.82) and TcB sternum (r = 0.80). A good discriminations ability was observed for both the TcB forehead (receiver operating characteristics [ROC] curve = 89.8%) and sternum (ROC curve = 89.7%) at a TSB level of 205 mu mol/L. The sensitivity ranges from 84.4% to 85.3%, while the specificity ranges from 77.4% to 76.4%. Conclusion: Our study demonstrates a strong linear relationship and good diagnostic accuracy of TcB values compared to TSB values. To conclude, TcB measured at the forehead or sternum is a good alternative as a non-invasive screening tool for non-severe hyperbilirubinemia in Malay neonates.
引用
收藏
页码:43 / 54
页数:12
相关论文
共 50 条
  • [21] Covered Skin Bilirubin Measurement during Phototherapy, in Comparison with Total Serum Bilirubin in Full Term Neonates
    Eldondity, Mohamed Ashraf
    Arafa, Reda Sanad
    Ameen, Seham Gouda
    Abed, Neveen Tawfik
    IRANIAN JOURNAL OF NEONATOLOGY, 2021, 12 (04) : 48 - 53
  • [22] Transcutaneous Bilirubin for Screening of Significant Jaundice in Very Preterm Neonates
    Chawla, Deepak
    INDIAN JOURNAL OF PEDIATRICS, 2019, 86 (01) : 4 - 4
  • [23] Simultaneous measurement of total transcutaneous bilirubin on forehead and chest as a predictive model for total serum bilirubin in premature and term newborns
    Esther Martinez-Mercado, Maria
    Fernando Torres-Bernal, Luis
    Gongora-Ortega, Javier
    del Rosario Sanchez-Ortiz, Maria
    Guerrero-Diaz de Leon, Jose Antonio
    ACTA PEDIATRICA DE MEXICO, 2014, 35 (02): : 106 - 110
  • [24] Accuracy of Neonatal Transcutaneous Bilirubin Measurement in the Outpatient Setting
    Wickremasinghe, Andrea C.
    Karon, Brad S.
    Cook, Walter J.
    CLINICAL PEDIATRICS, 2011, 50 (12) : 1144 - 1149
  • [25] Determination of Newborn Jaundice Level by Transcutaneous Bilirubin Measurement
    Karamavus, Yunus
    Ozkan, Mehmed
    2018 26TH SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2018,
  • [26] Concurrent measurement of total transcutaneous bilirubin over forehead and sternum as predictive model for total serum bilirubin in premature and term newborns
    Esther Martinez-Mercado, Maria
    Fernando Torres-Bernal, Luis
    Gongora-Ortega, Javier
    del Rosario Sanchez-Ortiz, Maria
    Guerrero-Diaz de Leon, Jose Antonio
    ACTA PEDIATRICA DE MEXICO, 2014, 35 (02): : 118 - 124
  • [27] Effectiveness of Transcutaneous Bilirubin Measurement in High-Risk Neonates and to Evaluate Validity of Transcutaneous Bilirubin With Total Serum Bilirubin Levels in Both Low and High-Risk Neonates at a Tertiary Care Center in a Developing Country
    Khan, Durre Shahwar
    Mirza, Adnan
    Bhatti, Areesh
    Shabbir, Ali
    Tariq, Batha
    Rizvi, Arjumand
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (03)
  • [28] Accuracy of Transcutaneous Bilirubin Measurement from Unexposed Skin with a New Generation Device in Neonates Receiving Phototherapy
    Yoruk, Iren
    Oguz, Demet
    Elevli, Murat
    Ataoglu, Emel
    HASEKI TIP BULTENI-MEDICAL BULLETIN OF HASEKI, 2022, 60 (02): : 113 - 119
  • [29] Transcutaneous bilirubin measurement during phototherapy in term neonates
    Katayama, Yoshinori
    Enomoto, Masahiro
    Kikuchi, Shin
    Takei, Atsuko
    Ikegami, Hitoshi
    Minami, Hirotaka
    Lee, Yong Kye
    PEDIATRICS INTERNATIONAL, 2017, 59 (06) : 686 - 690
  • [30] Effectiveness of transcutaneous bilirubin measurement in managing neonatal jaundice in postnatal ward of a tertiary care hospital in Pakistan
    Hussain, Ali Shabbir
    Shah, Muhammad Hussain
    Lakhdir, Maryam
    Ariff, Shabina
    Demas, Simon
    Qaiser, Fatima
    Ali, Syed Rehan
    BMJ PAEDIATRICS OPEN, 2017, 1 (01)