3D localization of vena contracta using Doppler ICE imaging in tricuspid valve interventions

被引:2
作者
Nisar, Hareem [1 ,2 ]
Fakim, Djalal [3 ]
Bainbridge, Daniel [4 ]
Chen, Elvis C. S. [1 ,2 ,3 ,5 ]
Peters, Terry [1 ,2 ,3 ,5 ]
机构
[1] Robarts Res Inst, 1151 Richmond St, London, ON N6A 5B7, Canada
[2] Western Univ, Sch Biomed Engn, 1151 Richmond St, London, ON N6A 3K7, Canada
[3] Western Univ, Schulic Sch Med & Dent, 1151 Richmond St, London, ON N6A 3K7, Canada
[4] London Hlth Sci Ctr, Dept Anesthesia & Perioperat Med, 339 Windermere Rd, London, ON N6A 5A5, Canada
[5] Western Univ, Dept Med Biophys, 1151 Richmond St, London, ON N6A 3K7, Canada
关键词
Tricuspid valve; Cardiac interventions; Intracardiac echocardiography (ICE); Image guided systems; Vena contracta localization; INTRACARDIAC ECHOCARDIOGRAPHY; REGURGITATION; REPAIR; ULTRASOUND; OUTCOMES;
D O I
10.1007/s11548-022-02660-w
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Tricuspid valve (TV) interventions face the challenge of imaging the anatomy and tools because of the 'TEE-unfriendly' nature of the TV. In edge-to-edge TV repair, a core step is to position the clip perpendicular to the coaptation gap. In this study, we provide a semi-automated method to localize the VC from Doppler intracardiac echo (ICE) imaging in a tracked 3D space, thus providing a pre-mapped location of the coaptation gap to assist device positioning. Methods A magnetically tracked ICE probe with Doppler imaging capabilities is employed in this study for imaging three patient-specific TVs placed in a pulsatile heart phantom. For each of the valves, the ICE probe is positioned to image the maximum regurgitant flow for five cardiac cycles. An algorithm then extracts the regurgitation imaging and computes the exact location of the vena contracta on the image. Results Across the three pathological, patient-specific valves, the average distance error between the detected VC and the ground truth model is (1.22 +/- 2.00)mm. For each of the valves, one case represented the outlier where the algorithm misidentified the vena contracta to be near the annulus. In such cases, it is recommended to retake the five-second imaging data. Conclusion This study presented a method for ultrasound-based localization of vena contracta in 3D space. Mapping such anatomical landmarks has the potential to assist with device positioning and to simplify tricuspid valve interventions by providing more contextual information to the interventionalists, thus enhancing their spatial awareness. Additionally, ICE can be used to provide live US and Doppler imaging of the complex TV anatomy throughout the procedure.
引用
收藏
页码:1569 / 1577
页数:9
相关论文
共 38 条
[1]   Intracardiac Echocardiography in Structural Heart Disease Interventions [J].
Alkhouli, Mohamad ;
Hijazi, Ziyad M. ;
Holmes, David R., Jr. ;
Rihal, Charanjit S. ;
Wiegers, Susan E. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (21) :2133-2147
[2]   Multimodality imaging of the tricuspid valve with implication for percutaneous repair approaches [J].
Ancona, Francesco ;
Stella, Stefano ;
Taramasso, Maurizio ;
Marini, Claudia ;
Latib, Azeem ;
Denti, Paolo ;
Grigioni, Francesco ;
Enriquez-Sarano, Maurice ;
Alfieri, Ottavio ;
Colombo, Antonio ;
Maisano, Francesco ;
Agricola, Eustachio .
HEART, 2017, 103 (14) :1073-1081
[3]   Management of tricuspid valve regurgitation [J].
Antunes, Manuel J. ;
Barlow, John B. .
HEART, 2007, 93 (02) :271-276
[4]   Intracardiac Echocardiography for Structural Heart and Electrophysiological Interventions [J].
Basman, Craig ;
Parmar, Yuvrajsinh J. ;
Kronzon, Itzhak .
CURRENT CARDIOLOGY REPORTS, 2017, 19 (10)
[5]   Predictors of Procedural and Clinical Outcomes in Patients With Symptomatic Tricuspid Regurgitation Undergoing Transcatheter Edge-to-Edge Repair [J].
Besler, Christian ;
Orban, Mathias ;
Rommel, Karl-Philipp ;
Braun, Daniel ;
Patel, Mehul ;
Hagl, Christian ;
Borger, Michael ;
Nabauer, Michael ;
Massberg, Steffen ;
Thiele, Holger ;
Hausleiter, Joerg ;
Lurz, Philipp .
JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (12) :1119-1128
[6]   Patient-specific, dynamic models of Hypoplastic left heart syndrome tricuspid valves for simulation and planning [J].
Boone, Nora ;
Nam, Hannah H. ;
Moore, John T. ;
Carnahan, Patrick ;
Ginty, Olivia ;
Herz, Christian ;
Lasso, Andras ;
Jolley, Matthew A. ;
Chen, Elvis C. S. ;
Peters, Terry .
MEDICAL IMAGING 2020: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2021, 11315
[7]   Tricuspid valve and percutaneous approach: No longer the forgotten valve! [J].
Bouleti, Claire ;
Juliard, Jean-Michel ;
Himbert, Dominique ;
Iung, Bernard ;
Brochet, Eric ;
Urena, Marina ;
Dilly, Marie-Pierre ;
Ou, Phalla ;
Nataf, Patrick ;
Vahanian, Alec .
ARCHIVES OF CARDIOVASCULAR DISEASES, 2016, 109 (01) :55-66
[8]  
BRAUNWALD NS, 1967, CIRCULATION, V35, pI63
[9]   Guided ultrasound calibration: where, how, and how many calibration fiducials [J].
Chen, Elvis C. S. ;
Peters, Terry M. ;
Ma, Burton .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (06) :889-898
[10]  
Courtney B, 2014, US PATENT