An Improved Resonant Frequency Based Systematic LCL Filter Design Method for Grid-Connected Inverter

被引:68
作者
Wu, Tsai-Fu [1 ]
Misra, Mitradatta [1 ]
Lin, Li-Chiun [1 ]
Hsu, Chih-Wei [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Elect Engn, Elegant Power Elect Appl Res Lab, Hsinchu 30013, Taiwan
关键词
Damping; design; division-summation (D-Sigma) digital control; harmonics; inductance variation; inverter; LCL filter; line impedance; magnetic permeability; resonant frequency; stability; SIGMA DIGITAL-CONTROL; CURRENT CONTROLLER; VOLTAGE; OPTIMIZATION;
D O I
10.1109/TIE.2017.2682004
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Resonant frequency of an LCL filter in a grid-connected inverter is an important factor for control stability and grid-injected current quality. However, the constraints on resonant frequency are usually considered as an afterthought in conventional filter design methods. The fact that resonant frequency is affected by both internal and external factors during operation makes it even more critical. Hence, an improved resonant frequency based systematic LCL filter design method is presented in this paper. A resonant frequency band is identified by considering grid-voltage harmonics and control stability boundary. The variation in resonant frequency due to inductive line impedance as well as magnetic permeability of inductor core is taken into account to define the constraints on LCL parameters. The LCL parameters are then systematically derived from the identified constraints with almost no iteration. A division-summation (D-Sigma) digital control method is used to validate the design method. Experimental results measured from a 5-kW single-phase grid-connected inverter have verified the effectiveness of the LCL filter design method over conventional methods.
引用
收藏
页码:6412 / 6421
页数:10
相关论文
共 37 条
[1]  
[Anonymous], 2014, IEEE Std 519-2014, P1
[2]  
[Anonymous], 2005, IEEE Std 1547.1-2005, DOI [10.1109/IEEESTD.2013.6673990, 10.1109/IEEESTD.2005.96469, DOI 10.1109/IEEESTD.2005.96469]
[3]   A Review of Passive Power Filters for Three-Phase Grid-Connected Voltage-Source Converters [J].
Beres, Remus Narcis ;
Wang, Xiongfei ;
Liserre, Marco ;
Blaabjerg, Frede ;
Bak, Claus Leth .
IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2016, 4 (01) :54-69
[4]   Optimal Design of High-Order Passive-Damped Filters for Grid-Connected Applications [J].
Beres, Remus Narcis ;
Wang, Xiongfei ;
Blaabjerg, Frede ;
Liserre, Marco ;
Bak, Claus Leth .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (03) :2083-2098
[5]   Filter Optimization for Grid Interactive Voltage Source Inverters [J].
Channegowda, Parikshith ;
John, Vinod .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (12) :4106-4114
[6]   Filter-Based Active Damping of Voltage Source Converters With LCL Filter [J].
Dannehl, Joerg ;
Liserre, Marco ;
Fuchs, Friedrich Wilhelm .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (08) :3623-3633
[7]   Investigation of Active Damping Approaches for PI-Based Current Control of Grid-Connected Pulse Width Modulation Converters With LCL Filters [J].
Dannehl, Joerg ;
Fuchs, Friedrich Wilhelm ;
Hansen, Steffan ;
Thogersen, Paul Bach .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2010, 46 (04) :1509-1517
[8]  
Dick Christian P., 2007, 2007 European Conference on Power Electronics and Applications, P1, DOI 10.1109/EPE.2007.4417362
[9]  
Gullvik William, 2007, 2007 European Conference on Power Electronics and Applications, P1, DOI 10.1109/EPE.2007.4417734
[10]  
HAVA AM, 1995, APPL POWER ELECT CO, P125, DOI 10.1109/APEC.1995.469010