Dosimetric characterization of the 60Co BEBIG Co0.A86 high dose rate brachytherapy source using PENELOPE

被引:16
作者
Guerrero, Rafael [1 ]
Almansa, Julio F. [2 ]
Torres, Javier [3 ]
Lallena, Antonio M. [4 ]
机构
[1] Hosp Univ San Cecilio, Serv Radiofis & Protecc Radiol, E-18012 Granada, Spain
[2] Hosp Reg Univ Virgen de las Nieves, Serv Fis & Protecc Radiol, E-18014 Granada, Spain
[3] Hosp Gen Univ Ciudad Real, Serv Radiofis & Protecc Radiol, E-13005 Ciudad Real, Spain
[4] Univ Granada, Dept Fis Atom Mol & Nucl, E-18071 Granada, Spain
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2014年 / 30卷 / 08期
关键词
Monte Carlo dosimetry; Co-60; HDR; PENELOPE; TECHNICAL NOTE; AAPM;
D O I
10.1016/j.ejmp.2014.06.039
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Co-60 sources are being used as an alternative to Ir-192 sources in high dose rate brachytherapy treatments. In a recent document from AAPM and ESTRO, a consensus dataset for the Co-60 BEBIG (model Co0.A86) high dose rate source was prepared by using results taken from different publications due to discrepancies observed among them. The aim of the present work is to provide a new calculation of the dosimetric characteristics of that Co-60 source according to the recommendations of the AAPM and ESTRO report. Radial dose function, anisotropy function, air-kerma strength, dose rate constant and absorbed dose rate in water have been calculated and compared to the results of previous works. Simulations using the two different geometries considered by other authors have been carried out and the effect of the cable density and length has been studied. (C) 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:960 / 967
页数:8
相关论文
共 18 条
  • [11] Dosimetric characterization of an 192Ir brachytherapy source with the Monte Carlo code PENELOPE
    Javier Casado, Francisco
    Garcia-Pareja, Salvador
    Cenizo, Elena
    Mateo, Beatriz
    Bodineau, Coral
    Galan, Pedro
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2010, 26 (03): : 132 - 139
  • [12] DOSIMETRY OF INTERSTITIAL BRACHYTHERAPY SOURCES - RECOMMENDATIONS OF THE AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO 43
    NATH, R
    ANDERSON, LL
    LUXTON, G
    WEAVER, KA
    WILLIAMSON, JF
    MEIGOONI, AS
    [J]. MEDICAL PHYSICS, 1995, 22 (02) : 209 - 234
  • [13] Perez-Calatayud J., 2012, Dose calculation for photon-emitting brachytherapy sources with average energy higher than 50 keV: Full report of the AAPM and ESTRO. Report of the HEBD Working Group
  • [14] Dose calculation for photon-emitting brachytherapy sources with average energy higher than 50 keV: Report of the AAPM and ESTRO
    Perez-Calatayud, Jose
    Ballester, Facundo
    Das, Rupak K.
    DeWerd, Larry A.
    Ibbott, Geoffrey S.
    Meigooni, Ali S.
    Ouhib, Zoubir
    Rivard, Mark J.
    Sloboda, Ron S.
    Williamson, Jeffrey F.
    [J]. MEDICAL PHYSICS, 2012, 39 (05) : 2904 - 2929
  • [15] Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations
    Rivard, MJ
    Coursey, BM
    DeWerd, LA
    Hanson, WF
    Huq, MS
    Ibbott, GS
    Mitch, MG
    Nath, R
    Williamson, JF
    [J]. MEDICAL PHYSICS, 2004, 31 (03) : 633 - 674
  • [16] Salvat F, 2012, PENELOPE 2011 CODE S
  • [17] Technical Note: EGSnrc-based dosimetric study of the BEBIG 60Co HDR brachytherapy sources
    Selvam, T. Palani
    Bhola, Subhalaxmi
    [J]. MEDICAL PHYSICS, 2010, 37 (03) : 1365 - 1370
  • [18] Dosimetry characterization of 32P intravascular brachytherapy source wires using Monte Carlo codes PENELOPE and GEANT4
    Torres, J
    Buades, MJ
    Almansa, JF
    Guerrero, R
    Lallena, AM
    [J]. MEDICAL PHYSICS, 2004, 31 (02) : 296 - 304