Primary total knee arthroplasty with rotating-hinge prosthesis in severely compromised knees

被引:0
作者
Leng, Yi [1 ]
Zeng, Min [2 ]
Hu, Yihe [2 ]
Zhu, Jianxi [2 ]
Su, Weiping [2 ]
Xie, Jie [2 ]
机构
[1] Cent S Univ, Dept Rehabil, Xiangya Hosp, 87 Xiangya Rd, Changsha 410008, Hunan, Peoples R China
[2] Cent S Univ, Xiangya Hosp, Dept Orthoped, 87 Xiangya Rd, Changsha 410008, Hunan, Peoples R China
来源
INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE | 2018年 / 11卷 / 06期
关键词
Knee; arthroplasty; rotating-hinge; surgical protocol; REVISION SURGERY; REPLACEMENT; SALVAGE; CONSTRAINT;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Aim: To evaluate the efficacy of primay total knee arthroplasty (TKA) with a rotating-hinge device in severely compromised knees. Methods: 28 patients who underwent primary TKA with rotating-hinge prosthesis at our institution from 2006 to 2012 were retrospectively reviewed. Indications for the use of a rotating-hinge prosthesis were extreme ligament imbalance or severe bone loss. Clinical evaluations were performed prior to surgery and at the final follow up which included visual analog scale (VAS), Hospital for Special Surgery (HSS) Knee Scores, range of motion (ROM) measurements, assessment of postoperative complications and radiographic data. Data were analyzed with Student's t test with significance at p < 0.05. Results: Mean follow-up period was 6.5 years (range 4-10 years). Mean VAS score decreased from 8.1 (range 6-10) preoperatively to 1.2 (range 0-3) at final follow-up (P=0.01). Mean HSS score improved from 38.5 (range 25-62) preoperatively to 86.3 (range 72-95) at final followup (P=0.02). Average ROM was 64 degrees (range 20-90 degrees) before surgery and 98 degrees (range 90-110 degrees) at final follow-up (P=0.04). There was no malalignment at the final follow-up. No signs of prosthesis subsidence or loosening were observed. Conclusion: Primary TKA using a rotating-hinge prosthesis is effective at improving the pain and function of severely compromised knees.
引用
收藏
页码:5867 / 5872
页数:6
相关论文
共 22 条
[1]   Total knee arthroplasty in femorotibial instability [J].
Argenson, JN ;
Aubaniac, JM .
ORTHOPADE, 2000, 29 (Suppl 1) :S45-S47
[2]  
Barrack RL, 2001, CLIN ORTHOP RELAT R, P292
[3]   The use of a modular rotating hinge component in salvage revision total knee arthroplasty [J].
Barrack, RL ;
Lyons, TR ;
Ingraham, RQ ;
Johnson, JC .
JOURNAL OF ARTHROPLASTY, 2000, 15 (07) :858-866
[4]  
EWALD FC, 1989, CLIN ORTHOP RELAT R, P9
[5]  
Felli L, 2016, ORTHOPADE, V45, P446, DOI 10.1007/s00132-015-3193-x
[6]   The role of hinges in primary total knee replacement [J].
Gehrke, T. ;
Kendoff, D. ;
Haasper, C. .
BONE & JOINT JOURNAL, 2014, 96B :93-95
[7]   Complications following rotating hinge Endo-Modell (Link®) knee arthroplasty [J].
Guenoun, B. ;
Latargez, L. ;
Freslon, M. ;
Defossez, G. ;
Salas, N. ;
Gayet, L. -E. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2009, 95 (07) :529-536
[8]   Is There a Place for Rotating-Hinge Arthroplasty in Knee Revision Surgery for Aseptic Loosening? [J].
Joshi, Nayana ;
Navarro-Quilis, Antonio .
JOURNAL OF ARTHROPLASTY, 2008, 23 (08) :1204-1211
[9]   Better Outcomes in Severe and Morbid Obese Patients (BMI &gt; 35 kg/m2) in Primary Endo-Model Rotating-Hinge Total Knee Arthroplasty [J].
Lozano, Luis M. ;
Lopez, Vicente ;
Rios, Jose ;
Popescu, Dragos ;
Torner, Pere ;
Castillo, Felix ;
Macule, Francisco .
SCIENTIFIC WORLD JOURNAL, 2012,
[10]  
Mavrodontidis Alexandros N, 2008, J Surg Orthop Adv, V17, P179