Ionic-liquid matrices for quantitative analysis by MALDI-TOF mass spectrometry

被引:119
作者
Li, YL [1 ]
Gross, ML [1 ]
机构
[1] Washington Univ, Dept Chem, St Louis, MO 63130 USA
关键词
D O I
10.1016/j.jasms.2004.08.011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Ionic liquid matrices (ILMs) were tested as MALDI matrices for quantification of oligode-oxynucleotides (ODNs), peptides, and small proteins. Good calibrations with high linearity and reproducibility were achieved over a broad concentration range for all the tested ILMs in spite of their different physical states. However, the standard deviation is higher for ILMs that are solid with visible crystals. The experimental results indicate various ILMs have different sensitivity owing to changes in their cation components. More importantly, we found that the slopes of the calibration curves correlate with the inverse of the peptide molecular weights, presenting an opportunity to predict a priori, the relative sensitivities (slopes of calibration plots) for various analytes that have similar hydrophobicites. (C) 2004 American Society for Mass Spectrometry.
引用
收藏
页码:1833 / 1837
页数:5
相关论文
共 33 条
[1]  
Amado FML, 1997, RAPID COMMUN MASS SP, V11, P1347, DOI 10.1002/(SICI)1097-0231(199708)11:12<1347::AID-RCM974>3.0.CO
[2]  
2-8
[3]   High-stability ionic liquids. A new class of stationary phases for gas chromatography [J].
Anderson, JL ;
Armstrong, DW .
ANALYTICAL CHEMISTRY, 2003, 75 (18) :4851-4858
[4]   Characterizing ionic liquids on the basis of multiple solvation interactions [J].
Anderson, JL ;
Ding, J ;
Welton, T ;
Armstrong, DW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (47) :14247-14254
[5]   Ionic liquids as matrixes for matrix-assisted laser desorption/ionization mass spectrometry [J].
Armstrong, DW ;
Zhang, LK ;
He, LF ;
Gross, ML .
ANALYTICAL CHEMISTRY, 2001, 73 (15) :3679-3686
[6]   Examination of ionic liquids and their interaction with molecules, when used as stationary phases in gas chromatography [J].
Armstrong, DW ;
He, LF ;
Liu, YS .
ANALYTICAL CHEMISTRY, 1999, 71 (17) :3873-3876
[7]   Wall-less sample preparation of μm-sized sample spots for femtomole detection limits of proteins from liquid based UV-MALDI matrices [J].
Bogan, MJ ;
Agnes, GR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2004, 15 (04) :486-495
[8]  
Bruenner BA, 1996, RAPID COMMUN MASS SP, V10, P1797
[9]   SURFACE-TENSION OF AMINO-ACID SOLUTIONS - HYDROPHOBICITY SCALE OF AMINO-ACID RESIDUES [J].
BULL, HB ;
BREESE, K .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1974, 161 (02) :665-670
[10]   Ionic matrices for matrix-assisted laser desorption/ionization time-of-flight detection of DNA oligomers [J].
Carda-Broch, S ;
Berthod, A ;
Armstrong, DW .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (06) :553-560