An Adaptive Active Damper for Improving the Stability of Grid-Connected Inverters Under Weak Grid

被引:124
作者
Jia, Lei [1 ]
Ruan, Xinbo [1 ]
Zhao, Wenxin [1 ]
Lin, Zhiheng [1 ]
Wang, Xuehua [2 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Automat Engn, Ctr More Elect Aircraft Power Syst, Nanjing 210016, Jiangsu, Peoples R China
[2] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Hubei, Peoples R China
基金
美国国家科学基金会;
关键词
Active damper; damping resistor; grid-connected inverter; stability; weak grid; LCL FILTER; CONTROLLER-DESIGN; POWER FILTER; PERFORMANCE; VSCS;
D O I
10.1109/TPEL.2018.2793242
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
When a grid-connected inverter is connected to a weak grid, the system may be unstable. An active damper can be connected to the point of common coupling (PCC), which simulates a virtual resistor to dampen the resonance and thus stabilize the system. In this paper, an adaptive tuning method of the virtual resistor is proposed, which can automatically regulate the virtual resistor to the critical value to stabilize the system, and thus reduce the power loss. Furthermore, the active damper is designed not to respond to the dominant low-frequency harmonic components in the PCC voltage introduced by the grid background harmonics, so that its power loss can be further reduced. In order to make the active damper more accurately simulate the virtual resistor in a wide frequency range, a harmonic-current-reference compensation method is proposed. The prototypes of a 6-kW grid-connected inverter and a 1-kVA active damper are built and tested to verify the effectiveness of the proposed control scheme of the active damper.
引用
收藏
页码:9561 / 9574
页数:14
相关论文
共 31 条
  • [1] A shunt active filter based on voltage detection for harmonic termination of a radial power distribution line
    Akagi, H
    Fujita, H
    Wada, K
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1999, 35 (03) : 638 - 645
  • [2] [Anonymous], 2014, IEEE Std 519-2014
  • [3] Passivity Enhancement of Grid-Tied Converters by Series LC-Filtered Active Damper
    Bai, Haofeng
    Wang, Xiongfei
    Loh, Poh Chiang
    Blaabjerg, Frede
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (01) : 369 - 379
  • [4] Step-by-Step Controller Design for LCL-Type Grid-Connected Inverter with Capacitor-Current-Feedback Active-Damping
    Bao, Chenlei
    Ruan, Xinbo
    Wang, Xuehua
    Li, Weiwei
    Pan, Donghua
    Weng, Kailei
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) : 1239 - 1253
  • [5] Bastiao F., 2013, P CIRED, P1
  • [6] Overview of control and grid synchronization for distributed power generation systems
    Blaabjerg, Frede
    Teodorescu, Remus
    Liserre, Marco
    Timbus, Adrian V.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) : 1398 - 1409
  • [7] Impedance-Phased Dynamic Control Method for Grid-Connected Inverters in a Weak Grid
    Chen, Xin
    Zhang, Yang
    Wang, Shanshan
    Chen, Jie
    Gong, Chunying
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (01) : 274 - 283
  • [8] Haofeng Bai, 2016, 2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia), P2937, DOI 10.1109/IPEMC.2016.7512764
  • [9] Frequency-domain passivity-based current controller design
    Harnefors, L.
    Zhang, L.
    Bongiorno, M.
    [J]. IET POWER ELECTRONICS, 2008, 1 (04) : 455 - 465
  • [10] Passivity-Based Stability Assessment of Grid-Connected VSCs-An Overview
    Harnefors, Lennart
    Wang, Xiongfei
    Yepes, Alejandro G.
    Blaabjerg, Frede
    [J]. IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2016, 4 (01) : 116 - 125