Effect of alternative photostimulable phosphor plates erasing times on subjective digital image quality

被引:3
作者
Melo, D. P. [1 ]
Pontual, A. dos Anjos [2 ]
de Almeida, S. M. [1 ]
Campos, P. S. F. [1 ]
Alves, M. C. [3 ]
Tosoni, G. M. [4 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Oral Diag, Div Oral Radiol, Piracicaba, SP, Brazil
[2] Univ Fed Pernambuco, Pernambuco Dent Sch, Dept Oral Diag, Div Oral Radiol, Camaragibe, PE, Brazil
[3] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Anat, Div Anat, Piracicaba, SP, Brazil
[4] Sao Paulo State Univ, Araraquara Dent Sch, Dept Oral Diag & Surg, Div Oral Radiol, Araraquara, SP, Brazil
关键词
dental radiography; digital imaging; density; contrast; CARIES DETECTION; DYNAMIC-RANGE; SYSTEMS; NOISE; PERFORMANCE; RADIOGRAPHY;
D O I
10.1259/dmfr/49065239
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate the influence of alternative erasing times of DenOptix (R) (Dentsply/Gendex, Chicargo, IL) digital plates oil subjective image quality and the probability of double exposure image not Occurring. Methods: Human teeth were X-rayed with phosphor plates using tell different erasing times. Two observers evaluated the images for subjective Image quality (sharpness, brightness, contrast, enamel definition, dentin definition and dentin-enamal Junction definition) and for the presence or absence of double exposure image. Spearman's correlation analysis and ANOVA was performed to verify the existence ora linear association between the subjective image quality parameters and the alternative erasing times. A contingency table was constructed to evaluate the agreement among the observers, and a binominal logistic regression was performed to verify the correlation between the erasing time and the probability of double exposure image not occurring. Results: All 6 parameters or image quality were rated high by the examiners for the erasing times between 25 s and 130 s. The same erasing time range, from 25 to 130 s, was considered a safe erasing time interval, with no probability of a double exposure image Occurring. Conclusions: The alternative erasing times from 25 s to 130 s showed high quality and no probability of double image Occurrence. Thus, it is possible to reduce the operating time or the DenOptix (R) digital system Without jeopardizing the diagnostic task. Dentomaxillofacial Radiology (2010) 39, 23-27. doi: 10.1259/dmfr/49065239.
引用
收藏
页码:23 / 27
页数:5
相关论文
共 21 条
[1]   Evaluation of PSPL plate erasing time of a digital dental radiology system [J].
Albuquerque, JAG ;
Costa, ET ;
Neto, FH ;
Paganinni, GA ;
Bóscolo, FN ;
de Oliveira, AEF .
MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 :227-235
[2]   Signal-to-noise ratios of 6 intraoral digital sensors [J].
Attaelmanan, AG ;
Borg, E ;
Gröndahl, HG .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2001, 91 (05) :611-615
[3]   The dynamic range of digital radiographic systems: dose reduction or risk of overexposure? [J].
Berkhout, WER ;
Beuger, DA ;
Sanderink, GCH ;
van der Stelt, PF .
DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (01) :1-5
[4]   On the dynamic range of different X-ray photon detectors in intra-oral radiography. A comparison of image quality in film, charge-coupled device and storage phosphor systems [J].
Borg, E ;
Grondahl, HG .
DENTOMAXILLOFACIAL RADIOLOGY, 1996, 25 (02) :82-88
[5]   Image plate systems differ in physical performance [J].
Borg, E ;
Attaelmanan, A ;
Gröndahl, HG .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2000, 89 (01) :118-124
[6]   Subjective image quality of solid-state and photostimulable phosphor systems for digital intra-oral radiography [J].
Borg, E ;
Attaelmanan, A ;
Gröndahl, HG .
DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (02) :70-75
[7]   Comments on noise and resolution of the DenOptix radiography system [J].
Couture, RA .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2003, 95 (06) :746-751
[8]  
*DENTSPL INT, 2005, GENDEX DENT XRAY DEN
[9]  
DOYLE P, 2005, RADIAT PROT DOSIM, V117, P113
[10]   Comparison of three intra-oral storage phosphor systems using subjective image quality [J].
Kitagawa, H ;
Farman, AG ;
Scheetz, JP ;
Brown, WP ;
Lewis, J ;
Benefiel, M ;
Kuroyanagi, K .
DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (05) :272-276