Nitrogen dynamics and removal in a horizontal flow biofilm reactor for wastewater treatment

被引:34
作者
Clifford, E. [1 ]
Nielsen, M. [1 ]
Sorensen, K. [2 ]
Rodgers, M. [1 ]
机构
[1] Natl Univ Ireland, Dept Civil Engn, Galway, Ireland
[2] Danish Technol Inst, DK-8000 Aarhus C, Denmark
关键词
Biofilm reactor; FISH; Potential nitrification rates; Horizontal flow biofilm reactor; Wastewater treatment; Reactor optimisation; STRENGTH WASTEWATERS; NITRIFYING BACTERIA; PERFORMANCE; EFFLUENT; DENITRIFICATION; POPULATIONS; OXIDATION; NITRITE; FILTERS; PROBES;
D O I
10.1016/j.watres.2010.04.042
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A horizontal flow biofilm reactor (HFBR) designed for the treatment of synthetic wastewater (SWW) was studied to examine the spatial distribution and dynamics of nitrogen transformation processes. Detailed analyses of bulk water and biomass samples, giving substrate and proportions of ammonia oxidising bacteria (AOB) and nitrite oxidising bacteria (NOB) gradients in the HFBR, were carried out using chemical analyses, sensor rate measurements and molecular techniques. Based on these results, proposals for the design of HFBR systems are presented. The HFBR comprised a stack of 60 polystyrene sheets with 10-mm deep frustums. SWW was intermittently dosed at two points, Sheets 1 and 38, in a 2 to 1 volume ratio respectively. Removals of 85.7% COD, 97.4% 5-day biochemical oxygen demand (BOD(5)) and 61.7% TN were recorded during the study. In the nitrification zones of the HFBR, which were separated by a step-feed zone, little variation in nitrification activity was found, despite decreasing in situ ammonia concentrations. The results further indicate significant simultaneous nitrification and denitrification (SND) activity in the nitrifying zones of the HFBR. Sensor measurements showed a linear increase in potential nitrification rates at temperatures between 7 and 16 degrees C, and similar rates of nitrification were measured at concentrations between 1 and 20 mg NH(4)-N/l. These results can be used to optimise HFBR reactor design. The HFBR technology could provide an alternative, low maintenance, economically efficient system for carbon and nitrogen removal for low flow wastewater discharges. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3819 / 3828
页数:10
相关论文
共 38 条
[21]   ROLE OF SATURATED AND UNSATURATED ZONE IN SOIL DISPOSAL OF SEPTIC-TANK EFFLUENT [J].
JOHNSON, KR ;
ATWATER, JW .
CANADIAN JOURNAL OF CIVIL ENGINEERING, 1988, 15 (04) :709-716
[22]  
Jonoud S., 2003, Iranian Journal of Biotechnology, V1, P115
[23]   Field evaluation of the performance of engineered on-site wastewater treatment units [J].
Lowe, Kathryn S. ;
Van Cuyk, Sheila M. ;
Siegrist, Robert L. ;
Drewes, Joerg E. .
JOURNAL OF HYDROLOGIC ENGINEERING, 2008, 13 (08) :735-743
[24]   Vertical distribution of nitrifying populations in bacterial biofilms from a full-scale nitrifying trickling filter [J].
Lydmark, Par ;
Lind, Magnus ;
Sorensson, Fred ;
Hermansson, Malte .
ENVIRONMENTAL MICROBIOLOGY, 2006, 8 (11) :2036-2049
[25]   Phylogenetic probes for analyzing abundance and spatial organization of nitrifying bacteria [J].
Mobarry, BK ;
Wagner, M ;
Urbain, V ;
Rittmann, BE ;
Stahl, DA .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1996, 62 (06) :2156-2162
[26]   On-line determination of nitrite in wastewater treatment by use of a biosensor [J].
Nielsen, M ;
Revsbech, NP ;
Larsen, LH ;
Lynggaard-Jensen, A .
WATER SCIENCE AND TECHNOLOGY, 2002, 45 (4-5) :69-76
[27]  
Odegaard H., 1980, P 1 NAT S WORKSH ROT, V2, P1301
[28]   Model experiments on improving nitrogen removal in laboratory scale subsurface constructed wetlands by enhancing the anaerobic ammonia oxidation [J].
Paredes, D. ;
Kuschk, P. ;
Stange, F. ;
Mueller, R. A. ;
Koeser, H. .
WATER SCIENCE AND TECHNOLOGY, 2007, 56 (03) :145-150
[29]  
Randall C., 1992, DESIGN RETROFIT WAST
[30]   Organic carbon removal and nitrification of high strength wastewaters using stratified sand filters [J].
Rodgers, M ;
Healy, MG ;
Mulqueen, J .
WATER RESEARCH, 2005, 39 (14) :3279-3286