Development and validation of a UPLC method for quantification of antiviral agent, Acyclovir in lipid-based formulations

被引:7
作者
Al-Amri, Khalid A. [1 ]
Mohsin, Kazi [1 ]
Alanazi, Fars K. [1 ]
机构
[1] King Saud Univ, Coll Pharm, Kayyali Chair Pharmaceut Ind, Riyadh, Saudi Arabia
关键词
Acyclovir; UPLC; Lipid based formulation; Validation; LIQUID-CHROMATOGRAPHIC METHOD; HUMAN PLASMA; QUANTITATIVE-ANALYSIS; ELECTROPHORESIS; AMANTADINE; PRECISION; ACCURACY; ASSAY;
D O I
10.1016/j.arabjc.2014.08.024
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Purpose: The objective of the current study is to evaluate the Ultra Performance Liquid Chromatography (UPLC) method for quantification of Acyclovir in lipid-based formulations. Method: A simple, rapid, reliable and precise reversed phase UPLC method has been developed and validated according to the regulatory guidelines, which composed of isocratic mobile phase; 0.25% formic acid (FA) in Milli-Q water with a flow rate of 0.5 ml/min, and column BEH C18 (2.1 x 50 mm, 1.7 mu m). The detection was carried out at 254 nm. Results: The developed UPLC method was found to be rapid (1.2 min run time), selective with well resoluted Acyclovir peak (0.89 min) from different lipid matrices and sensitive (Limit of Detection (LOD) was 0.3 ppm and Lower Limit of Quantification (LLOQ) was 1 ppm). The accuracy and precision were determined and were perfectly matching with the standard FDA limits. Conclusion: The study showed that the proposed UPLC method can be used for the assessment of drug purity, stability, solubility and lipid-formulation release profile with no interference of excipients or related substances of active pharmaceutical ingredient. (C) 2014 Production and hosting by Elsevier B.V. on behalf of King Saud University.
引用
收藏
页码:1707 / 1714
页数:8
相关论文
共 25 条
  • [1] Flow injection potentiometric determination of amantadine HCl
    Abdel-Ghani, NT
    Shoukry, AF
    Hussein, SH
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (03) : 601 - 611
  • [2] Abdel-Hamid M, 2012, ASIAN J CHEM, V24, P595
  • [3] Validated liquid chromatographic-fluorescence method for the quantitation of gemifloxacin in human plasma
    Al-Hadiya, Badraddin M. H.
    Khady, Adnan A.
    Mostafa, Gamal A. E.
    [J]. TALANTA, 2010, 83 (01) : 110 - 116
  • [4] Stability indicating simultaneous determination of domperidone (DP), methylparaben (MP) and propylparaben by high performance liquid chromatography (HPLC)
    Ali, MS
    Ghori, M
    Khatri, AR
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (02) : 358 - 365
  • [5] Biowaiver Monographs for Immediate Release Solid Oral Dosage Forms: Aciclovir
    Arnal, J.
    Gonzalez-Alvarez, I.
    Bermejo, M.
    Amidon, G. L.
    Junginger, H. E.
    Kopp, S.
    Midha, K. K.
    Shah, V. P.
    Stavchansky, S.
    Dressman, J. B.
    Barends, D. M.
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 2008, 97 (12) : 5061 - 5073
  • [6] Basavaiah K., 2003, Farmaco (Lausanne), V58, P1301, DOI 10.1016/S0014-827X(03)00157-5
  • [7] Development and validation of UPLC method for determination of primaquine phosphate and its impurities
    Dongre, Vaijanath G.
    Karmuse, Pravin P.
    Rao, Pilla Prakasa
    Kumar, Ashok
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 46 (02) : 236 - 242
  • [8] Precision and Accuracy in the Quantitative Analysis of Biological Samples by Accelerator Mass Spectrometry: Application in Microdose Absolute Bioavailability Studies
    Gao, Lan
    Li, Jing
    Kasserra, Claudia
    Song, Qi
    Aromand, Ali
    Hesk, David
    Chowdhury, Swapan K.
    [J]. ANALYTICAL CHEMISTRY, 2011, 83 (14) : 5607 - 5616
  • [9] PRECISION, ACCURACY, AND DATA ACCEPTANCE CRITERIA IN BIOPHARMACEUTICAL ANALYSIS
    KARNES, HT
    MARCH, C
    [J]. PHARMACEUTICAL RESEARCH, 1993, 10 (10) : 1420 - 1426
  • [10] Quantitative analysis of memantine in human plasma by gas chromatography/negative ion chemical ionization/mass spectrometry
    Leis, HJ
    Fauler, G
    Windischhofer, W
    [J]. JOURNAL OF MASS SPECTROMETRY, 2002, 37 (05): : 477 - 480