Morphometry of organ cultured corneal endothelium using Voronoi segmentation

被引:7
作者
Brookes, Nigel H. [1 ,2 ]
机构
[1] Univ Auckland, New Zealand Natl Eye Bank, Private Bag 92019, Auckland 1142, New Zealand
[2] Univ Auckland, Dept Ophthalmol, Private Bag 92019, Auckland 1142, New Zealand
关键词
Cornea; Endothelium; Organ culture; Morphometry; Voronoi; Segmentation; CELL-DENSITY; SPECULAR MICROSCOPY; IMAGE-ANALYSIS; EYE-BANK; AUTOMATIC ESTIMATION; HEXAGONAL CELLS; FLEX-CENTER; DONOR; ORGANIZATION; MORPHOLOGY;
D O I
10.1007/s10561-017-9622-9
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
The endothelial viability of eye-banked corneas must be assessed before transplantation, yet phase-contrast images of the endothelium of corneas stored in an Organ Culture system have a huge variety of endothelial appearance at different focal planes, due to stromal swelling and an evaluation technique that swells the cells and their intercellular spaces to make them visible. This makes them difficult to assess using common edge-based segmentation methodologies that have mostly been developed in vivo using specular microscopy. Additionally, as the endothelial cell architecture has radically different form at apical and basal poles, segmentation of only the apical view cannot describe the cell as a whole. Using custom software, this study instead defines the cell borders using a calibrated Voronoi diagram, a region-based image segmentation technique that uses a point cloud of cell centroids as the only input required to measure the size (polymegathism) and shape (pleomorphism) of the endothelial cells. Measurements included the range and variation in the cell area and density, the number of cell sides, and several novel shape descriptors. A dataset of endothelial cell measurements was compiled from 2000 images of 678 corneas comprising 354,998 cells, and validated by comparison to previous studies from a variety of tissue sources, imaging modalities, and analysis techniques. While there were some differences in cell size variation and pleomorphic composition than seen in some other studies, much of the data was directly comparable, demonstrating fast and accurate endothelial cell morphometry at a large scale for a wide range of routine organ cultured corneas.
引用
收藏
页码:167 / 183
页数:17
相关论文
共 50 条
[31]   Comparison of the structural integrity and quality of corneal endothelium stored in organ culture storage medium versus Eusol-C [J].
Wang, Qin ;
Liu, Yonghuan ;
Gao, Yang ;
Zhang, Ming ;
Yang, Lihong ;
Hu, Jian ;
Ren, Yi ;
Zhou, Qizhi ;
Zhu, Meidong .
CELL AND TISSUE BANKING, 2024, 25 (03) :839-850
[32]   Survival of corneal nerve/sheath structures in organ-cultured donor corneas [J].
Dhillon, Virinder K. ;
Elalfy, Mohamed S. ;
Messina, Marco ;
Al-Aqaba, Mouhamed ;
Dua, Harminder S. .
ACTA OPHTHALMOLOGICA, 2018, 96 (03) :E334-E340
[33]   Organ-cultured corneal grafts from septic donors: a retrospective study [J].
H Spelsberg ;
T Reinhard ;
U Sengler ;
W Daeubener ;
R Sundmacher .
Eye, 2002, 16 :622-627
[34]   Organ-cultured corneal grafts from septic donors: a retrospective study [J].
Spelsberg, H ;
Reinhard, T ;
Sengler, U ;
Daeubener, W ;
Sundmacher, R .
EYE, 2002, 16 (05) :622-627
[35]   Self-supervised deep-learning segmentation of corneal endothelium specular microscopy images [J].
Sanchez, Sergio ;
Mendoza, Kevin ;
Quintero, Fernando J. ;
Prada, Angelica M. ;
Tello, Alejandro ;
Galvis, Virgilio ;
Romero, Lenny A. ;
Marrugo, Andres G. .
2023 IEEE COLOMBIAN CONFERENCE ON APPLICATIONS OF COMPUTATIONAL INTELLIGENCE, COLCACI, 2023,
[36]   Fully convolutional architecture vs sliding-window CNN for corneal endothelium cell segmentation [J].
Juan P. Vigueras-Guillén ;
Busra Sari ;
Stanley F. Goes ;
Hans G. Lemij ;
Jeroen van Rooij ;
Koenraad A. Vermeer ;
Lucas J. van Vliet .
BMC Biomedical Engineering, 1 (1)
[37]   Automated corneal endothelium image segmentation in the presence of cornea guttata via convolutional neural networks [J].
Sierra, Juan S. ;
Pineda, Jesus ;
Viteri, Eduardo ;
Rueda, Daniela ;
Tibaduiza, Beatriz ;
Berrospi, Ruben D. ;
Tello, Alejandro ;
Galvis, Virgilio ;
Volpe, Giovanni ;
Millan, Maria S. ;
Romero, Lenny A. ;
Marrugo, Andres G. .
APPLICATIONS OF MACHINE LEARNING 2020, 2020, 11511
[38]   Automatic detection of the region of interest in corneal endothelium images using dense convolutional neural networks [J].
Vigueras-Guillen, Juan P. ;
Lemij, Hans G. ;
van Rooij, Jeroen ;
Vermeer, Koenraad A. ;
van Vliet, Lucas J. .
MEDICAL IMAGING 2019: IMAGE PROCESSING, 2019, 10949
[39]   Mechanisms underlying impairment of endothelium-dependent relaxation by fetal bovine serum in organ-cultured rat mesenteric artery [J].
Morita, Tomoka ;
Okada, Muneyoshi ;
Hara, Yukio ;
Yamawaki, Hideyuki .
EUROPEAN JOURNAL OF PHARMACOLOGY, 2011, 668 (03) :401-406
[40]   Short-term effect of intracameral triamcinolone acetonide on corneal endothelium using the rabbit model [J].
Oh, J. Y. ;
Wee, W. R. ;
Lee, J. H. ;
Kim, M. K. .
EYE, 2007, 21 (06) :812-818