Large-Scale Assessment of a Smartwatch to Identify Atrial Fibrillation

被引:1050
作者
Perez, Marco V. [1 ]
Mahaffey, Kenneth W. [2 ]
Hedlin, Haley [3 ]
Rumsfeld, John S. [9 ]
Garcia, Ariadna [3 ]
Ferris, Todd [4 ]
Balasubramanian, Vidhya [3 ]
Russo, Andrea M. [10 ]
Rajmane, Amol [2 ]
Cheung, Lauren [7 ]
Hung, Grace [4 ]
Lee, Justin [3 ]
Kowey, Peter [11 ,12 ]
Talati, Nisha [2 ]
Nag, Divya [7 ]
Gummidipundi, Santosh E. [3 ]
Beatty, Alexis [7 ]
Hills, Mellanie True [13 ]
Desai, Sumbul [5 ,7 ]
Granger, Christopher B. [14 ]
Desai, Manisha [3 ]
Turakhia, Mintu P. [6 ,8 ]
机构
[1] Stanford Univ, Div Cardiovasc Med, Stanford, CA 94305 USA
[2] Stanford Univ, Stanford Ctr Clin Res, Stanford, CA 94305 USA
[3] Stanford Univ, Quantitat Sci Unit, Stanford, CA 94305 USA
[4] Stanford Univ, Informat Resources & Technol, Stanford, CA 94305 USA
[5] Stanford Univ, Dept Med, Stanford, CA 94305 USA
[6] Stanford Univ, Ctr Digital Hlth, Stanford, CA 94305 USA
[7] Apple, Cupertino, CA USA
[8] Vet Affairs Palo Alto Hlth Care Syst, Palo Alto, CA USA
[9] Univ Colorado, Sch Med, Aurora, CO USA
[10] Rowan Univ, Div Cardiovasc Dis, Cooper Med Sch, Camden, NJ USA
[11] Lankenau Heart Inst, Philadelphia, PA USA
[12] Jefferson Med Coll, Philadelphia, PA USA
[13] Amer Fdn Womens Hlth, StopAfib Org, Decatur, TX USA
[14] Duke Univ, Duke Clin Res Inst, Durham, NC USA
关键词
RISK-FACTOR; STROKE;
D O I
10.1056/NEJMoa1901183
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Using a smartphone app, the investigators recruited 419,297 participants to be monitored for irregular pulses. Patterns suggesting atrial fibrillation were detected in 2161 participants who then received ECG monitoring devices to be worn for 7 days to confirm the presence or absence of atrial fibrillation. Background Optical sensors on wearable devices can detect irregular pulses. The ability of a smartwatch application (app) to identify atrial fibrillation during typical use is unknown. Methods Participants without atrial fibrillation (as reported by the participants themselves) used a smartphone (Apple iPhone) app to consent to monitoring. If a smartwatch-based irregular pulse notification algorithm identified possible atrial fibrillation, a telemedicine visit was initiated and an electrocardiography (ECG) patch was mailed to the participant, to be worn for up to 7 days. Surveys were administered 90 days after notification of the irregular pulse and at the end of the study. The main objectives were to estimate the proportion of notified participants with atrial fibrillation shown on an ECG patch and the positive predictive value of irregular pulse intervals with a targeted confidence interval width of 0.10. Results We recruited 419,297 participants over 8 months. Over a median of 117 days of monitoring, 2161 participants (0.52%) received notifications of irregular pulse. Among the 450 participants who returned ECG patches containing data that could be analyzed - which had been applied, on average, 13 days after notification - atrial fibrillation was present in 34% (97.5% confidence interval [CI], 29 to 39) overall and in 35% (97.5% CI, 27 to 43) of participants 65 years of age or older. Among participants who were notified of an irregular pulse, the positive predictive value was 0.84 (95% CI, 0.76 to 0.92) for observing atrial fibrillation on the ECG simultaneously with a subsequent irregular pulse notification and 0.71 (97.5% CI, 0.69 to 0.74) for observing atrial fibrillation on the ECG simultaneously with a subsequent irregular tachogram. Of 1376 notified participants who returned a 90-day survey, 57% contacted health care providers outside the study. There were no reports of serious app-related adverse events. Conclusions The probability of receiving an irregular pulse notification was low. Among participants who received notification of an irregular pulse, 34% had atrial fibrillation on subsequent ECG patch readings and 84% of notifications were concordant with atrial fibrillation. This siteless (no on-site visits were required for the participants), pragmatic study design provides a foundation for large-scale pragmatic studies in which outcomes or adherence can be reliably assessed with user-owned devices. (Funded by Apple; Apple Heart Study ClinicalTrials.gov number, NCT03335800.).)
引用
收藏
页码:1909 / 1917
页数:9
相关论文
共 13 条
  • [1] Apple, 2018, US APPL WATCH ARRH D
  • [2] Incidence and Clinical Significance of New-Onset Device-Detected Atrial Tachyarrhythmia A Meta-Analysis
    Belkin, Mark N.
    Soria, Cesar E.
    Waldo, Albert L.
    Borleffs, C. Jan Willem
    Hayes, David L.
    Tung, Roderick
    Singh, Jagmeet P.
    Upadhyay, Gaurav A.
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2018, 11 (03)
  • [3] Estimates of Current and Future Incidence and Prevalence of Atrial Fibrillation in the US Adult Population
    Colilla, Susan
    Crow, Ann
    Petkun, William
    Singer, Daniel E.
    Simon, Teresa
    Liu, Xianchen
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2013, 112 (08) : 1142 - 1147
  • [4] Response by Halcox and Wareham to Letter Regarding Article, "Assessment of Remote Heart Rhythm Sampling Using the AliveCor Heart Monitor to Screen for Atrial Fibrillation: The REHEARSE-AF Study"
    Halcox, Julian P. J.
    Wareham, Kathie
    [J]. CIRCULATION, 2018, 137 (20) : 2193 - 2194
  • [5] Subclinical Atrial Fibrillation and the Risk of Stroke
    Healey, Jeff S.
    Connolly, Stuart J.
    Gold, Michael R.
    Israel, Carsten W.
    Van Gelder, Isabelle C.
    Capucci, Alessandro
    Lau, C. P.
    Fain, Eric
    Yang, Sean
    Bailleul, Christophe
    Morillo, Carlos A.
    Carlson, Mark
    Themeles, Ellison
    Kaufman, Elizabeth S.
    Hohnloser, Stefan H.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2012, 366 (02) : 120 - 129
  • [6] Cryptogenic Stroke and Underlying Atrial Fibrillation
    Sanna, Tommaso
    Diener, Hans-Christoph
    Passman, Rod S.
    Di Lazzaro, Vincenzo
    Bernstein, Richard A.
    Morillo, Carlos A.
    Rymer, Marilyn Mollman
    Thijs, Vincent
    Rogers, Tyson
    Beckers, Frank
    Lindborg, Kate
    Brachmann, Johannes
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2014, 370 (26) : 2478 - 2486
  • [7] Effect of a Home-Based Wearable Continuous ECG Monitoring Patch on Detection of Undiagnosed Atrial Fibrillation The mSToPS Randomized Clinical Trial
    Steinhubl, Steven R.
    Waalen, Jill
    Edwards, Alison M.
    Ariniello, Lauren M.
    Mehta, Rajesh R.
    Ebner, Gail S.
    Carter, Chureen
    Baca-Motes, Katie
    Felicione, Elise
    Sarich, Troy
    Topol, Eric J.
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2018, 320 (02): : 146 - 155
  • [8] Physical Activity Surveillance Through Smartphone Apps and Wearable Trackers: Examining the UK Potential for Nationally Representative Sampling
    Strain, Tessa
    Wijndaele, Katrien
    Brage, Soren
    [J]. JMIR MHEALTH AND UHEALTH, 2019, 7 (01):
  • [9] Passive Detection of Atrial Fibrillation Using a Commercially Available Smartwatch
    Tison, Geoffrey H.
    Sanchez, Jose M.
    Ballinger, Brandon
    Singh, Avesh
    Olgin, Jeffrey E.
    Pletcher, Mark J.
    Vittinghoff, Eric
    Lee, Emily S.
    Fan, Shannon M.
    Gladstone, Rachel A.
    Mikell, Carlos
    Sohoni, Nimit
    Hsieh, Johnson
    Marcus, Gregory M.
    [J]. JAMA CARDIOLOGY, 2018, 3 (05) : 409 - 416
  • [10] Rationale and design of a large-scale, app-based study to identify cardiac arrhythmias using a smartwatch: The Apple Heart Study
    Turakhia, Mintu P.
    Desai, Manisha
    Hedlin, Haley
    Rajmane, Amol
    Talati, Nisha
    Ferris, Todd
    Desai, Sumbul
    Nag, Divya
    Patel, Mithun
    Kowey, Peter
    Rumsfeld, John S.
    Russo, Andrea M.
    Hills, Mellanie True
    Granger, Christopher B.
    Mahaffey, Kenneth W.
    Perez, Marco V.
    [J]. AMERICAN HEART JOURNAL, 2019, 207 : 66 - 75