The purpose of the present study was to evaluate the feasibility of blood pressure (BP) estimation by means of pulse arrival time (PAT) from data records of ICU patients available at the MIMIC public database. Datasets consisting of ECG, PPG and arterial BP waveforms from 8 subjects were used for the analysis and the relationship of PAT with systolic, diastolic and mean blood pressure was assessed through a linear regression fit. The analysis was carried out on datasets of short (20 min) and long (60 min) duration in order to evaluate the temporal changes on the linear relationship. The results showed high correlation between BP and PAT for both the short-term and the long-term analyses. The mean absolute error found between the true and estimated systolic BP values was close to 5mmHg; however, the error noticeably increased on the long-term dataset for all subjects.
引用
收藏
页码:1113 / 1116
页数:4
相关论文
共 49 条
  • [31] Assessment of Pulse Transit/Arrival Time as Noninvasive Blood Pressure Predictors in Finger and Earlobe Sites
    Selvaraj, Nandakumar
    2016 IEEE HEALTHCARE INNOVATION POINT-OF-CARE TECHNOLOGIES CONFERENCE (HI-POCT), 2016, : 200 - 203
  • [32] A Laboratory Study on Non-Invasive Soil Water Content Estimation Using Capacitive Based Sensors
    Orangi, Amir
    Narsilio, Guillermo A.
    Ryu, Dongryeol
    SENSORS, 2019, 19 (03)
  • [33] A Photoacoustics based Continuous Non-Invasive Blood Glucose Monitoring System
    Pai, Praful P.
    Sanki, Pradyut K.
    Banerjee, Swapna
    2015 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA) PROCEEDINGS, 2015, : 106 - 111
  • [34] Development of a non-invasive blood glucose monitor based on impedance measurements
    Malinin, Len
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2012, 8 (01) : 60 - 81
  • [35] WAKE-BPAT: WAVELET-BASED ADAPTIVE KALMAN FILTERING FOR BLOOD PRESSURE ESTIMATION VIA FUSION OF PULSE ARRIVAL TIMES
    Kalantar, Golnar
    Mukhopadhyay, Sourav K.
    Marefat, Fatemeh
    Mohseni, Pedram
    Mohammadi, Arash
    2018 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2018, : 945 - 949
  • [36] Noninvasive and continuous blood pressure monitoring with better accuracy by combining pulse arrival time and peak delay
    Li, Yibin
    Li, Shengnan
    Deng, Ning
    INTERNATIONAL JOURNAL OF DISTRIBUTED SENSOR NETWORKS, 2018, 14 (12):
  • [37] Pulse Arrival Time Based Cuff-Less and 24-H Wearable Blood Pressure Monitoring and its Diagnostic Value in Hypertension
    Zheng, Yali
    Poon, Carmen C. Y.
    Yan, Bryan P.
    Lau, James Y. W.
    JOURNAL OF MEDICAL SYSTEMS, 2016, 40 (09)
  • [38] Validation of non-invasive central blood pressure devices: ARTERY Society task force consensus statement on protocol standardization
    Sharman, James E.
    Avolio, Alberto P.
    Baulmann, Johannes
    Benetos, Athanase
    Blacher, Jacques
    Blizzard, C. Leigh
    Boutouyrie, Pierre
    Chen, Chen-Huan
    Chowienczyk, Phil
    Cockcroft, John R.
    Cruickshank, J. Kennedy
    Ferreira, Isabel
    Ghiadoni, Lorenzo
    Hughes, Alun
    Jankowski, Piotr
    Laurent, Stephane
    McDonnell, Barry J.
    McEniery, Carmel
    Millasseau, Sandrine C.
    Papaioannou, Theodoros G.
    Parati, Gianfranco
    Park, Jeong Bae
    Protogerou, Athanase D.
    Roman, Mary J.
    Schillaci, Giuseppe
    Segers, Patrick
    Stergiou, George S.
    Tomiyama, Hirofumi
    Townsend, Raymond R.
    Van Bortel, Luc M.
    Wang, Jiguang
    Wassertheurer, Siegfried
    Weber, Thomas
    Wilkinson, Ian B.
    Vlachopoulos, Charalambos
    EUROPEAN HEART JOURNAL, 2017, 38 (37) : 2805 - +
  • [39] Infrared absorption spectroscopy-based non-invasive blood glucose monitoring technology: A comprehensive review
    Li, Taixiang
    Wang, Quangui
    An, Ying
    Guo, Lin
    Ren, Linan
    Lei, Linghao
    Chen, Xianlai
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2025, 106
  • [40] A feasibility study on the non-invasive analysis of bottled Compound E Jiao oral liquid using near infrared spectroscopy
    Li, Wenlong
    Han, Haifan
    Zhang, Lu
    Zhang, Yan
    Qu, Haibin
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 211 : 131 - 137