Development and validation of ultra-high performance supercritical fluid chromatography method for quantitative determination of nine sunscreens in cosmetic samples

被引:24
作者
Khalikova, Maria A. [1 ]
Lesellier, Eric [2 ]
Chapuzet, Eric [3 ]
Satinsky, Dalibor [1 ]
West, Caroline [2 ]
机构
[1] Charles Univ Prague, Fac Pharm Hradec Kralove, Dept Analyt Chem, Ak Heyrovskeho 1203, Hradec Kralove 50005, Czech Republic
[2] Univ Orleans, ICOA, CNRS, UMR 7311,Pole Chim, Rue Chartres,BP 6759, F-45067 Orleans 2, France
[3] QUALILAB, 1121 Rue Bergeresse, F-45160 Olivet, France
关键词
Accuracy profile; Inter-laboratory reproducibility; Sunscreen; Supercritical fluid chromatography; UV filter; PHASE LIQUID-CHROMATOGRAPHY; SOLUBLE UV FILTERS; STATIONARY PHASES; SUNCARE PRODUCTS; MOBILE-PHASE; EXTRACTION; AGENTS; CLASSIFICATION; FORMULATIONS; RESOLUTION;
D O I
10.1016/j.aca.2018.06.013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fast and simple utra-high performance supercritical fluid chromatography (UHPSFC) method has been developed for the determination of nine sunscreens (UV filters), namely 2-ethylhexyl-2-hydroxybenzoate (ES), ethylhexyl-methoxycinnamate (EMC), benzophenone-3 (BZ3), octocrylene (OCR), bis-ethylhexyloxyphenol-methoxyphenyl triazine (EMT), butyl-methoxydibenzoyl-methane (BDM), diethylamino-hydroxybenzoyl-hexyl-benzoate (DHB), ethylhexyl-triazone (ET), and diethylhexyl-butamido-triazone (DBT) in cosmetic samples. The separation was achieved with Acquity UPC2 Torus 2-PIC (100 x 3.0 mm, 1.7 mu m) column. The influence of key chromatographic parameters on resolution was evaluated. The optimal mobile phase was a gradient mixture of carbon dioxide and methanol containing ammonium acetate, at flow rate 1.2 mL min(-1). The back-pressure of the system was set to 150 bar and the temperature to 40 degrees C. The compounds were determined with diode-array detection at 280 nm, 305 nm and 340 nm depending on absorbance maxima. The proposed UHPSFC method provided separation of the nine target sunscreens within 2.5 min without labor-consuming sample pretreatment procedure. The method was validated according to the concept of the total error and the accuracy profile. The inter-laboratory reproducibility was evaluated between two independent laboratories (in France and Czech Republic). The reliability of the developed method was shown by application to commercial sunscreen-containing cosmetic sample obtained from French market. The measured limits of quantification showed the suitability of the proposed method for determination of UV filters considering the European Union requirements. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:184 / 194
页数:11
相关论文
共 43 条
[1]   Impact of injection solvents on supercritical fluid chromatography [J].
Abrahamsson, Victor ;
Sandahl, Margareta .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1306 :80-88
[2]   Comparison of supercritical fluid chromatography and reverse phase liquid chromatography for the impurity profiling of the antiretroviral drugs lamivudine/BMS-986001/efavirenz in a combination tablet [J].
Alexander, A. J. ;
Zhang, L. ;
Hooker, T. F. ;
Tomasella, F. P. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 78-79 :243-251
[3]   Optimization and validation of a fast supercritical fluid chromatography method for the quantitative determination of vitamin D3 and its related impurities [J].
Andri, B. ;
Lebrun, P. ;
Dispas, A. ;
Klinkenberg, R. ;
Streel, B. ;
Ziemons, E. ;
Marini, R. D. ;
Hubert, Ph. .
JOURNAL OF CHROMATOGRAPHY A, 2017, 1491 :171-181
[4]   Determination of water-soluble UV filters in sunscreen sprays by liquid chromatography [J].
Chisvert, A ;
Salvador, A .
JOURNAL OF CHROMATOGRAPHY A, 2002, 977 (02) :277-280
[5]   Determination of UV-filters in sunscreens by HPLC [J].
Chisvert, A ;
Pascual-Martí, MC ;
Salvador, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 369 (7-8) :638-641
[6]   Determination of the UV filters worldwide authorised in sunscreens by high-performance liquid chromatography -: Use of cyclodextrins as mobile phase modifier [J].
Chisvert, A ;
Pascual-Martí, MC ;
Salvador, A .
JOURNAL OF CHROMATOGRAPHY A, 2001, 921 (02) :207-215
[7]   A reliable and environmentally-friendly liquid-chromatographic method for multi-class determination of fat-soluble UV filters in cosmetic products [J].
Chisvert, Alberto ;
Tarazona, Isuha ;
Salvador, Amparo .
ANALYTICA CHIMICA ACTA, 2013, 790 :61-67
[8]  
Dencausse L., 2008, International Journal of Cosmetic Science, V30, P373, DOI 10.1111/j.1468-2494.2008.00461.x
[9]   A systematic investigation of sample diluents in modern supercritical fluid chromatography [J].
Desfontaine, Vincent ;
Tarafder, Abhijit ;
Hill, Jason ;
Fairchild, Jacob ;
Perrenoud, Alexandre Grand -Guillaume ;
Veuthey, Jean-Luc ;
Guillarme, Davy .
JOURNAL OF CHROMATOGRAPHY A, 2017, 1511 :122-131
[10]   Supercritical fluid chromatography in pharmaceutical analysis [J].
Desfontaine, Vincent ;
Guillarme, Davy ;
Francotte, Eric ;
Novakova, Lucie .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 113 :56-71