Comparative Study of a Clean Technology Based on DSF Use in Occupied Buildings for Improving Comfort in Winter

被引:2
作者
Conceicao, Eusebio [1 ]
Gomes, Joao [2 ]
Lucio, Maria Manuela [1 ]
Conceicao, Maria Ines [3 ]
Awbi, Hazim [4 ]
机构
[1] Univ Algarve, Fac Ciencias & Tecnol, Campus Gambelas, P-8005139 Faro, Portugal
[2] CINTAL, Campus Gambelas, P-8005139 Faro, Portugal
[3] Inst Super Tecn, Ave Rovisco Pais, P-1049001 Lisbon, Portugal
[4] Univ Reading, Sch Construct Management & Engn, Reading RG6 6AW, Berks, England
来源
CLEAN TECHNOLOGIES | 2021年 / 3卷 / 02期
关键词
clean technology; clean energies; DSF; solar radiation; building thermal behavior; thermal comfort level; air quality level; uncomfortable hours; DOUBLE SKIN FACADE; THERMAL PERFORMANCE; ENERGY PERFORMANCE; NUMERICAL-SIMULATION; NATURAL-CONVECTION; HVAC SYSTEMS; AIR-FLOW; VENTILATION; TEMPERATURE; BEHAVIOR;
D O I
10.3390/cleantechnol3020018
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents a comparative study of a clean technology based on a DSF (double skin facade) used in winter conditions in the occupied buildings comfort improvement, namely the thermal comfort and air quality. The performance of a solar DSF system, the building's thermal response, the internal thermal comfort and the internal air quality are evaluated. In this study, a DSF system, an air transport system and a HVAC (heating, ventilating and air conditioning) system based on mixing ventilation are used. The study considers a virtual chamber occupied by eight persons and equipped, in the outside environment, by three DSFs. A new horary pre-programming control methodology is developed and applied when the airflow rate is constant and the number of DSFs to operate is variable, when the airflow rate is variable and the number of DSFs to operate is constant and when the airflow rate is variable and the number of DSFs to operate is variable. This work uses a numerical model that simulates the integral building thermal behavior and an integral human thermal response. The internal air, provided by a mixing ventilating system, is warmed using the DSF system. The air temperature inside the DSF system and the virtual chamber, the thermal comfort level using the PMV index, the internal air quality using the carbon dioxide concentration and the uncomfortable hours are calculated for winter conditions. The results obtained show that the energy produced in the DSF, using solar radiation, guarantees acceptable thermal comfort conditions in the morning and in the afternoon. The indoor air quality obtained at the breathing level is acceptable. It is found that the airflow rate to be used is more decisive than the DSF operating methodology. However, when a solution is chosen that combines a ventilation rate with the number of DSF to operate, both variables throughout the day can obtain simultaneously better results for indoor air quality and thermal comfort according to the standards.
引用
收藏
页码:311 / 334
页数:24
相关论文
共 33 条
  • [21] Comparative Study between a Copolymer Based on Oleic Acid and Its Nanohybrid for Improving the Cold Flow Properties of Diesel Fuel
    El-Segaey, Abeer A.
    El-Azabawy, Ragaa E.
    Mohammed, Hoda A.
    Al-Shafey, Hussin I.
    Kamal, Rasha S.
    [J]. ACS OMEGA, 2023, 8 (11): : 10426 - 10438
  • [22] A Study on Teachers' Willingness to Use Generative AI Technology and Its Influencing Factors: Based on an Integrated Model
    Lu, Haili
    He, Lin
    Yu, Hao
    Pan, Tao
    Fu, Kefeng
    [J]. SUSTAINABILITY, 2024, 16 (16)
  • [23] Comparative study on the use of cationic-nonionic-organo-montmorillonite in oil-based drilling fluids
    Zhuang, Guanzheng
    Zhang, Zepeng
    Fu, Meng
    Ye, Xian
    Liao, Libing
    [J]. APPLIED CLAY SCIENCE, 2015, 116 : 257 - 262
  • [24] Data-Based RC Dynamic Modelling Incorporating Physical Criteria to Obtain the HLC of In-Use Buildings: Application to a Case Study
    Paola Diaz-Hernandez, Heidi
    Rene Torres-Hernandez, Pablo
    Maria Aguilar-Castro, Karla
    Vicente Macias-Melo, Edgar
    Jose Jimenez, Maria
    [J]. ENERGIES, 2020, 13 (02)
  • [25] Using Real Building Energy Use Data to Explain the Energy Performance Gap of Energy-Efficient Residential Buildings: A Case Study from the Hot Summer and Cold Winter Zone in China
    Wang, Xia
    Yuan, Jiachen
    You, Kairui
    Ma, Xianrui
    Li, Zhaoji
    [J]. SUSTAINABILITY, 2023, 15 (02)
  • [26] Study on Accuracy of CFD Simulations of Wind Environment around High-Rise Buildings: A Comparative Study of k-ε Turbulence Models Based on Polyhedral Meshes and Wind Tunnel Experiments
    Xiong, Minghui
    Chen, Bing
    Zhang, Hua
    Qian, Yao
    [J]. APPLIED SCIENCES-BASEL, 2022, 12 (14):
  • [27] Is building energy simulation based on TMY representative: A comparative simulation study on doe reference buildings in Toronto with typical year and historical year type weather files
    Siu, Chun Yin
    Liao, Zaiyi
    [J]. ENERGY AND BUILDINGS, 2020, 211 (211)
  • [28] A Comparative Study of Information and Communication Technology (ICT)-Based and Conventional Methods of Instruction on Learners' Academic Enthusiasm for L2 Learning
    Fannakhosrow, Mahboubeh
    Nourabadi, Soolmaz
    Dinh Tran Ngoc Huy
    Nguyen Dinh Trung
    Tashtoush, Mohammad A.
    [J]. EDUCATION RESEARCH INTERNATIONAL, 2022, 2022
  • [29] Experimental evaluation of an indirect type solar dryer for agricultural use in rural communities: Relative humidity comparative study under winter season in tropical climate with sensible heat storage material
    Cetina-Quinones, A. J.
    Lopez, J. Lopez
    Ricalde-Cab, L.
    El Mekaoui, Amina
    San-Pedro, L.
    Bassam, A.
    [J]. SOLAR ENERGY, 2021, 224 : 58 - 75
  • [30] Exploring willingness to use adverse drug reaction reporting systems: a multicentre qualitative study in China based on the technology acceptance model and task-technology fit integration approach
    Xia, Xudong
    Yang, Xue
    Du, Jiayi
    Cheng, Weigao
    Chen, Xiaobo
    Zhang, Wan
    Yin, Zhao
    [J]. BMJ OPEN, 2024, 14 (10):