Comparative Study of a Clean Technology Based on DSF Use in Occupied Buildings for Improving Comfort in Winter

被引:2
|
作者
Conceicao, Eusebio [1 ]
Gomes, Joao [2 ]
Lucio, Maria Manuela [1 ]
Conceicao, Maria Ines [3 ]
Awbi, Hazim [4 ]
机构
[1] Univ Algarve, Fac Ciencias & Tecnol, Campus Gambelas, P-8005139 Faro, Portugal
[2] CINTAL, Campus Gambelas, P-8005139 Faro, Portugal
[3] Inst Super Tecn, Ave Rovisco Pais, P-1049001 Lisbon, Portugal
[4] Univ Reading, Sch Construct Management & Engn, Reading RG6 6AW, Berks, England
来源
CLEAN TECHNOLOGIES | 2021年 / 3卷 / 02期
关键词
clean technology; clean energies; DSF; solar radiation; building thermal behavior; thermal comfort level; air quality level; uncomfortable hours; DOUBLE SKIN FACADE; THERMAL PERFORMANCE; ENERGY PERFORMANCE; NUMERICAL-SIMULATION; NATURAL-CONVECTION; HVAC SYSTEMS; AIR-FLOW; VENTILATION; TEMPERATURE; BEHAVIOR;
D O I
10.3390/cleantechnol3020018
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents a comparative study of a clean technology based on a DSF (double skin facade) used in winter conditions in the occupied buildings comfort improvement, namely the thermal comfort and air quality. The performance of a solar DSF system, the building's thermal response, the internal thermal comfort and the internal air quality are evaluated. In this study, a DSF system, an air transport system and a HVAC (heating, ventilating and air conditioning) system based on mixing ventilation are used. The study considers a virtual chamber occupied by eight persons and equipped, in the outside environment, by three DSFs. A new horary pre-programming control methodology is developed and applied when the airflow rate is constant and the number of DSFs to operate is variable, when the airflow rate is variable and the number of DSFs to operate is constant and when the airflow rate is variable and the number of DSFs to operate is variable. This work uses a numerical model that simulates the integral building thermal behavior and an integral human thermal response. The internal air, provided by a mixing ventilating system, is warmed using the DSF system. The air temperature inside the DSF system and the virtual chamber, the thermal comfort level using the PMV index, the internal air quality using the carbon dioxide concentration and the uncomfortable hours are calculated for winter conditions. The results obtained show that the energy produced in the DSF, using solar radiation, guarantees acceptable thermal comfort conditions in the morning and in the afternoon. The indoor air quality obtained at the breathing level is acceptable. It is found that the airflow rate to be used is more decisive than the DSF operating methodology. However, when a solution is chosen that combines a ventilation rate with the number of DSF to operate, both variables throughout the day can obtain simultaneously better results for indoor air quality and thermal comfort according to the standards.
引用
收藏
页码:311 / 334
页数:24
相关论文
共 33 条
  • [1] Improving winter thermal comfort in Mediterranean buildings upgrading the envelope: An adaptive assessment based on a real survey
    Blazquez, T.
    Suarez, R.
    Ferrari, S.
    Sendra, J. J.
    ENERGY AND BUILDINGS, 2023, 278
  • [2] Green Roofs as Effective Tools for Improving the Indoor Comfort Levels of Buildings-An Application to a Case Study in Sicily
    Cirrincione, Laura
    La Gennusa, Maria
    Peri, Giorgia
    Rizzo, Gianfranco
    Scaccianoce, Gianluca
    Sorrentino, Giancarlo
    Aprile, Simona
    APPLIED SCIENCES-BASEL, 2020, 10 (03):
  • [3] Study on Winter Comfort Temperature in Mixed Mode and HVAC Office Buildings in Japan
    Khadka, Supriya
    Rijal, Hom B.
    Amano, Katsunori
    Saito, Teruyuki
    Imagawa, Hikaru
    Uno, Tomoko
    Genjo, Kahori
    Takata, Hiroshi
    Tsuzuki, Kazuyo
    Nakaya, Takashi
    Nishina, Daisaku
    Hasegawa, Kenichi
    Mori, Taro
    ENERGIES, 2022, 15 (19)
  • [4] Comparative study of room temperature control in buildings with and without the use of PCM in walls
    Gobinath, S.
    Senthilkumar, G.
    Beemkumar, N.
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2018, 40 (14) : 1765 - 1771
  • [5] Outdoor thermal comfort during winter in China's cold regions: A comparative study
    An, Le
    Hong, Bo
    Cui, Xue
    Geng, Yubo
    Ma, Xiaoyan
    SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 768
  • [6] The use of artificial intelligence (AI) methods in the prediction of thermal comfort in buildings: energy implications of AI-based thermal comfort controls
    Ngarambe, Jack
    Yun, Geun Young
    Santamouris, Mat
    ENERGY AND BUILDINGS, 2020, 211
  • [7] Comparative study on thermal comfort of sports buildings in hot and humid climates from the perspective of exercisers and non-exercisers
    Huang, Xiaodan
    Xun, Yi
    Zhao, Cheng
    Chen, Guang
    Guo, Wenzhi
    BUILDING AND ENVIRONMENT, 2023, 246
  • [8] Optimal Design Based on Computer Simulation for Improving Thermal Comfort in the Passage Space around Arcade Buildings in a Hot and Humid Climate
    Wei, Jin
    Yu, Fangsi
    He, Jiang
    ADVANCES IN ELECTRONIC COMMERCE, WEB APPLICATION AND COMMUNICATION, VOL 2, 2012, 149 : 327 - 334
  • [9] Pedestrian wind comfort around buildings: Comparison of wind comfort criteria based on whole-flow field data for a complex case study
    Janssen, W. D.
    Blocken, B.
    van Hooff, T.
    BUILDING AND ENVIRONMENT, 2013, 59 : 547 - 562
  • [10] Climate Adaptation Analysis and Comfort Optimization Strategies for Traditional Residential Buildings in Hot-Summer, Cold-Winter Regions: A Case Study in Xuzhou, China
    Zhang, Minghao
    Liu, Fang
    Liu, Qian
    Zhang, Fangyu
    Li, Tingshen
    SUSTAINABILITY, 2024, 16 (08)