Striking Differences in Platelet Distribution between Advanced-Platelet-Rich Fibrin and Concentrated Growth Factors: Effects of Silica-Containing Plastic Tubes

被引:20
|
作者
Tsujino, Tetsuhiro [1 ]
Masuki, Hideo [1 ]
Nakamura, Masayuki [1 ]
Isobe, Kazushige [1 ]
Kawabata, Hideo [1 ]
Aizawa, Hachidai [1 ]
Watanabe, Taisuke [1 ]
Kitamura, Yutaka [1 ]
Okudera, Hajime [1 ]
Okuda, Kazuhiro [2 ]
Nakata, Koh [3 ]
Kawase, Tomoyuki [4 ]
机构
[1] Tokyo Plast Dent Soc, Kita Ku, Tokyo 1140002, Japan
[2] Niigata Univ, Inst Med & Dent, Div Periodontol, Niigata 9518514, Japan
[3] Niigata Univ Med & Dent Hosp, Biosci Med Res Ctr, Niigata 9518520, Japan
[4] Niigata Univ, Inst Med & Dent, Div Oral Bioengn, Niigata 9518514, Japan
关键词
advanced platelet-rich fibrin; concentrated growth factors; platelets; CD41; centrifugal force; silica; PLASMA; PROTOCOL; PRF; STANDARDIZATION; ARCHITECTURE; RELEASE; SAFETY; CLOT;
D O I
10.3390/jfb10030043
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Compared with platelet-rich plasma, the preparation of platelet-rich fibrin (PRF) is simple and has not been overly modified. However, it was recently demonstrated that centrifugation conditions influence the composition of PRF and that silica microparticles from silica-coated plastic tubes can enter the PRF matrix. These factors may also modify platelet distribution. To examine these possibilities, we prepared PRF matrices using various types of blood-collection tubes (plain glass tubes and silica-containing plastic tubes) and different centrifugation speeds. The protocols of concentrated growth factors and advanced-PRF represented high- and low-speed centrifugation, respectively. Platelet distribution in the PRF matrix was examined immunohistochemically. Using low-speed centrifugation, platelets were distributed homogeneously within the PRF matrix regardless of tube types. In high-speed centrifugation, platelets were distributed mainly on one surface region of the PRF matrix in glass tubes, whereas in silica-coated tubes, platelet distribution was commonly more diffusive than in glass tubes. Therefore, both blood-collection tube types and centrifugal conditions appeared to influence platelet distribution in the PRF matrix. Platelets distributed in the deep regions of the PRF matrix may contribute to better growth factor retention and release. However, clinicians should be careful in using silica-coated tubes because their silica microparticles may be a health hazard.
引用
收藏
页数:11
相关论文
共 22 条
  • [21] Growth Factors Released from Advanced Platelet-Rich Fibrin in the Presence of Calcium-Based Silicate Materials and Their Impact on the Viability and Migration of Stem Cells of Apical Papilla
    Smoczer, Cristine
    Yuth, Kenneth R.
    Askar, Mazin A.
    Young, Laura A.
    Paurazas, Susan B.
    DENTISTRY JOURNAL, 2023, 11 (09)
  • [22] Radiographic and immuno-histochemical evaluation of root perforation repair using MTA with or without platelet-rich fibrin or concentrated growth factors as an internal matrix in dog’s teeth: in vivo animal study
    Dalia Abd-Allah Mohamed
    Safinaz AbdelFatah Abdelwahab
    Rania Hanafi Mahmoud
    Rasha Mohamed Taha
    Clinical Oral Investigations, 2023, 27 : 5103 - 5119