Prediction of time of delivery using cervical length measurement in women with threatened preterm labor

被引:4
作者
Ho, Nicole [1 ]
Liu, Cathy [1 ]
Anh Nguyen [1 ]
Lehner, Christoph [2 ]
Amoako, Akwasi [1 ]
Sekar, Renuka [2 ]
机构
[1] Univ Queensland, Fac Med, Discipline Obstet & Gynaecol, Brisbane, Qld, Australia
[2] Royal Brisbane & Womens Hosp, Dept Obstet & Gynaecol, Brisbane, Qld, Australia
关键词
Cervical length; preterm delivery; preterm labor; singleton pregnancy; transvaginal ultrasound; BIRTH; PREGNANCIES; PREVENTION;
D O I
10.1080/14767058.2019.1670798
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To evaluate the use of transvaginal (TV) sonographic cervical length (CL) measurement alone in predicting time of delivery in women who present in threatened preterm labor. Methods: A retrospective cohort study at Royal Brisbane and Women?s Hospital of all women who presented between 22?weeks and 0?days and 35?weeks and six-day gestation in threatened preterm labor and were admitted for ongoing management including a TV sonographic CL measure. The accuracy of CL for predicting time of delivery was compared between women with a short cervix (CL ?<?25?mm) and those with a normal cervix (CL ?25?mm). The predictive accuracy of CL for spontaneous preterm delivery was analyzed with different outcome-specific thresholds. Results: One hundred and forty-six women with threatened preterm labor met the inclusion criteria; of which 74 (50.7%) had a short cervix and 72 (49.3%) had a normal cervix. The group with short cervix were more likely to deliver prematurely before 37-week gestation, as well as a shorter time interval between initial presentation and delivery and delivery within 14?days from presentation (p?=?.0002, p?=?.0001, and p?=?.0001, respectively). Similarly, with respect to the area under the receiver operator characteristic curves, CL measurement was found to be significant for time of delivery before or after 37?weeks (p?<?.0001), preterm delivery before 34 (p?=??.0003) and 31 (p?<??.0001) weeks; and preterm delivery within 14?days from presentation (p?<?.0001). Cervical length measurement has a high negative predictive value ranging from 94.9 to 97.1% depending on the different CL threshold used. Conclusions: Cervical length measurement at the time of presentation was significantly associated with the risk of preterm delivery in women presenting with threatened preterm labor and a short cervix. Cervical length measurement was also helpful in predicting time of delivery within 14?days from presentation. The negative predictive value and predictive accuracy of CL as a single measure were of significance.
引用
收藏
页码:2649 / 2654
页数:6
相关论文
共 20 条
[1]  
[Anonymous], 2010, ANT MAGN SULPH PRIOR
[2]   Cervical length screening for prevention of preterm birth in singleton pregnancy with threatened preterm labor: systematic review and meta-analysis of randomized controlled trials using individual patient-level data [J].
Berghella, V. ;
Palacio, M. ;
Ness, A. ;
Alfirevic, Z. ;
Nicolaides, K. H. ;
Saccone, G. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2017, 49 (03) :322-U34
[3]   Adverse Pregnancy Outcomes After Treatment for Cervical Intraepithelial Neoplasia [J].
Bjorge, Tone ;
Skare, Gry B. ;
Bjorge, Line ;
Trope, Ameli ;
Lonnberg, Stefan .
OBSTETRICS AND GYNECOLOGY, 2016, 128 (06) :1265-1273
[4]   The predictive value of quantitative fibronectin testing in combination with cervical length measurement in symptomatic women [J].
Bruijn, Merel M. C. ;
Kamphuis, Esme I. ;
Hoesli, Irene M. ;
de Tejada, Begona Martinez ;
Loccufier, Anne R. ;
Kuhnert, Maritta ;
Helmer, Hanns ;
Franz, Marie ;
Porath, Martina M. ;
Oudijk, Martijn A. ;
Jacquemyn, Yves ;
Schulzke, Sven M. ;
Vetter, Grit ;
Hoste, Griet ;
Vis, Jolande Y. ;
Kok, Marjolein ;
Mol, Ben W. J. ;
van Baaren, Gert-Jan .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2016, 215 (06)
[5]   The risk of preterm birth following treatment for precancerous changes in the cervix: a systematic review and meta-analysis [J].
Bruinsma, F. J. ;
Quinn, M. A. .
BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2011, 118 (09) :1031-1041
[6]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[7]   Preterm birth 1 - Epidemiology and causes of preterm birth [J].
Goldenberg, Robert L. ;
Culhane, Jennifer F. ;
Iams, Jay D. ;
Romero, Roberto .
LANCET, 2008, 371 (9606) :75-84
[8]   Role of Cervical Length Measurement for Preterm Delivery Prediction in Women With Threatened Preterm Labor and Cervical Dilatation [J].
Hiersch, Liran ;
Melamed, Nir ;
Aviram, Amir ;
Bardin, Ron ;
Yogev, Yariv ;
Ashwal, Eran .
JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (12) :2631-2640
[9]  
Kiefer Daniel G, 2008, Rev Obstet Gynecol, V1, P106
[10]   The association between fetal fibronectin and spontaneous preterm birth in twin pregnancies with a shortened cervical length [J].
Matthews, Kathy C. ;
Gupta, Simi ;
Lam-Rachlin, Jennifer ;
Saltzman, Daniel H. ;
Rebarber, Andrei ;
Fox, Nathan S. .
JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2018, 31 (19) :2564-2568