High-spatial-resolution contrast-enhanced MR angiography of the intracranial venous system with fourfold accelerated two-dimensional sensitivity encoding

被引:19
作者
Hu, Houchun H. [1 ]
Campeau, Norbert G. [1 ]
Huston, John, III [1 ]
Kruger, David G. [1 ]
Haider, Clifton R. [1 ]
Riederer, Stephen J. [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Coll Med, Dept Radiol, Magnet Resonance Lab, Rochester, MN 55905 USA
关键词
D O I
10.1148/radiol.2433060819
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Informed consent was obtained; the study was HIPAA compliant and institutional review board approved. Fourfold accelerated (FFA) two-dimensional (2D) sensitivity encoding (SENSE) (65 seconds) was prospectively compared with its nonaccelerated counterpart (4 minutes 20 seconds) for diagnostic image quality and sharpness of visualization of blood vessels at 1.5 T with three-dimensional (3D) intracranial contrast-enhanced magnetic resonance venography in 18 consecutive volunteers (10 men, eight women; mean age, 48.4 years) and two patients (55-year-old man, 30-year-old woman). Two readers compared FFA 2D SENSE results with results from its nonaccelerated counterpart; they rated visualization of large and medium sinuses as equivalent (P > .1) and that of small deep cerebral veins (P < .01) and superficial cerebral veins (P < .001) as superior. Overall diagnostic image quality ratings were excellent for 62% and 80% of nonaccelerated and FFA 2D SENSE results, respectively (P < .05). FFA 2D SENSE may become the method of choice for fast visualization of intracranial venous vasculature in clinical practice.
引用
收藏
页码:853 / 861
页数:9
相关论文
共 32 条
[1]  
Ayanzen RH, 2000, AM J NEURORADIOL, V21, P74
[2]   Role of contrast-enhanced MR venography in the preoperative evaluation of parasagittal meningiomas [J].
Bozzao, A ;
Finocchi, V ;
Romano, A ;
Ferrante, M ;
Fasoli, F ;
Trillò, G ;
Ferrante, L ;
Fantozzi, LM .
EUROPEAN RADIOLOGY, 2005, 15 (09) :1790-1796
[3]  
DORMONT D, 1995, AM J NEURORADIOL, V16, P1347
[4]   INTRACEREBRAL ARTERIOVENOUS-MALFORMATIONS - EVALUATION WITH SELECTIVE MR ANGIOGRAPHY AND VENOGRAPHY [J].
EDELMAN, RR ;
WENTZ, KU ;
MATTLE, HP ;
OREILLY, GV ;
CANDIA, G ;
CHENG, L ;
BIN, Z ;
KJELLBERG, RN ;
DAVIS, KR .
RADIOLOGY, 1989, 173 (03) :831-837
[5]  
Fain SB, 1999, MAGNET RESON MED, V42, P1106, DOI 10.1002/(SICI)1522-2594(199912)42:6<1106::AID-MRM15>3.0.CO
[6]  
2-Q
[7]   Intracranial venous system: Gadolinium-enhanced three-dimensional MR venography with auto-trigered elliptic centric-ordered sequence - Initial experience [J].
Farb, RI ;
Scott, JN ;
Willinsky, RA ;
Montanera, W ;
Wright, GA ;
terBrugge, KG .
RADIOLOGY, 2003, 226 (01) :203-209
[8]   Comparison of different MR venography techniques for detecting transverse sinus stenosis in idiopathic intracranial hypertension [J].
Fera, F ;
Bono, F ;
Messina, D ;
Gallo, O ;
Lanza, PL ;
Auteri, W ;
Nicoletti, G ;
Santoro, G ;
Quattrone, A .
JOURNAL OF NEUROLOGY, 2005, 252 (09) :1021-1025
[9]  
Griswold MA, 1999, MAGNET RESON MED, V41, P1236, DOI 10.1002/(SICI)1522-2594(199906)41:6<1236::AID-MRM21>3.0.CO
[10]  
2-T