Feasibility Study of Human Corneal Endothelial Cell Transplantation Using an In Vitro Human Corneal Model

被引:5
作者
Rolev, Kostadin [1 ,2 ,3 ]
O'Donovan, Dominic G. [4 ]
Coussons, Peter [1 ,2 ]
King, Linda [1 ,2 ]
Rajan, Madhavan S. [1 ,2 ,5 ]
机构
[1] Anglia Ruskin Univ, Dept Biomed & Forens Sci, Cambridge, Cambs, England
[2] Anglia Ruskin Univ, Vis & Eye Res Unit Cambridge, Cambridge, Cambs, England
[3] Imperial Coll London, Dept Bioengn, Royal Sch Mines, London SW7 2BP, England
[4] Cambridge Univ Hosp, Dept Histopathol, Cambridge, Cambs, England
[5] Cambridge Univ Hosp, Dept Ophthalmol, Cambridge, Cambs, England
关键词
corneal endothelium; human corneal endothelial cell culture; corneal endothelial cell transplantation; cell therapy approach; CULTURED ADULT HUMAN; FELINE MODEL; STEM-CELLS; EX-VIVO; RABBIT; TGF-BETA-2; EXPRESSION; CARRIER; REPAIR; SHEET;
D O I
10.1097/ICO.0000000000001555
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To test the feasibility of a cell therapy approach to treat corneal endothelial (CE) disorders using an in vitro model of human corneal decompensation. Methods: A CE decompensation model was established by removal of the Descemet membrane/endothelium complex from cadaveric human corneas in an air interface organ culture system (group 2) and compared with normal corneas (group 1). The posterior stroma of decompensated corneas was seeded with immortalized human corneal endothelial cells (HCEC-12) in group 3 and passage 0 primary human CE cells in group 4 corneas. Functional effects on stromal thickness were determined with histological analysis 3 to 10 days after cell therapy treatment. Results: Removal of the Descemet membrane/endothelium complex in group 2 corneas resulted in a stromal thickness of 903 +/- 86 mu m at 12 hours compared with 557 +/- 72 mu m in group 1 corneas. Stromal thickness reduced from 1218 +/- 153 mu m to 458 +/- 90 mu m (63% +/- 6%, P = 0.001) after cell transplantation in group 3 and from 1100 +/- 86 mu m to 489 +/- 94 mu m (55% +/- 7%, P = 0.00004) in group 4. Posttransplantation histology demonstrated formation of a monolayer of corneal endothelium attached to the posterior stromal surface. Conclusions: Direct transplantation of cultured human CE cells and immortalized HCEC-12 to bare posterior corneal stroma resulted in formation of an endothelial monolayer and restoration of stromal hydration to physiological thickness, demonstrating the feasibility of cell therapy in treatment of CE decompensation in a human in vitro model.
引用
收藏
页码:778 / 784
页数:7
相关论文
共 36 条
  • [1] Morphological and functional analysis of immortalized human corneal endothelial cells after transplantation
    Aboalchamat, B
    Engelmann, K
    Böhnke, M
    Eggli, P
    Bednarz, J
    [J]. EXPERIMENTAL EYE RESEARCH, 1999, 69 (05) : 547 - 553
  • [2] BAHN CF, 1982, INVEST OPHTH VIS SCI, V22, P73
  • [3] Böhnke M, 1999, CORNEA, V18, P207
  • [4] In Vivo Functionality of a Corneal Endothelium Transplanted by Cell-Injection Therapy in a Feline Model
    Bostan, Cristina
    Theriault, Mathieu
    Forget, Karolyn J.
    Doyon, Christelle
    Cameron, J. Douglas
    Proulx, Stephanie
    Brunette, Isabelle
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (04) : 1620 - 1634
  • [5] Transplantation of adult human corneal endothelium ex vivo - A morphologic study
    Chen, KH
    Azar, D
    Joyce, NC
    [J]. CORNEA, 2001, 20 (07) : 731 - 737
  • [6] Chen KH, 1999, INVEST OPHTH VIS SCI, V40, P2513
  • [7] Bioengineering endothelialized neo-corneas using donor-derived corneal endothelial cells and decellularized corneal stroma
    Choi, Jin San
    Williams, James K.
    Greven, Margaret
    Walter, Keith A.
    Laber, Patrick W.
    Khang, Gilson
    Soker, Shay
    [J]. BIOMATERIALS, 2010, 31 (26) : 6738 - 6745
  • [8] METABOLIC BASIS TO FLUID PUMP IN CORNEA
    DIKSTEIN, S
    MAURICE, DM
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1972, 221 (01): : 29 - &
  • [9] Transplantation of adult human or porcine corneal endothelial cells onto human recipients in vitro.: Part I:: Cell culturing and transplantation procedure
    Engelmann, K
    Drexler, D
    Böhnke, M
    [J]. CORNEA, 1999, 18 (02) : 199 - 206
  • [10] Engelmann Katrin, 1993, Ophthalmologe, V90, P166