A noninvasive optical system for the measurement of xylem and phloem sap flow in woody plants of small stem size

被引:28
作者
Helfter, Carole [1 ]
Shephard, Jonathan D.
Martinez-Vilalta, Jordi
Mencuccini, Maurizio
Hand, Duncan P.
机构
[1] Heriot Watt Univ, Appl Opt & Photon Grp, Edinburgh, Midlothian, Scotland
[2] Univ Edinburgh, Sch Geosci, Edinburgh EH8 9YL, Midlothian, Scotland
关键词
heat pulse technique; single-sensor; surface measurements;
D O I
10.1093/treephys/27.2.169
中图分类号
S7 [林业];
学科分类号
0829 ; 0907 ;
摘要
Over the past 70 years, heat has been widely used as a tracer for estimating the flow of water in woody and herbaceous plants. However, most commercially available techniques for monitoring whole plant water use are invasive and the measurements are potentially flawed because of wounding of the xylem tissue. The study of photosynthate transport in the phloem remains in its infancy, and little information about phloem transport rates is available owing to the fragility of the vascular tissue. The aim of our study was to develop a compact, stand-alone non-invasive system allowing for direct detection of phloem and xylem sap movement. The proposed method uses a heat pulse as a tracer for sap flow. Heat is applied to the surface of the stem with a near-infrared laser Source, and heat propagation is monitored externally by means of an infrared camera. Heat Pulse velocities are determined from the thermometric data and related to the more useful quantity, mass flow rate. Simulation experiments on the xylem tissue of severed silver birch (Betula pendula Roth.) branch segments were performed to assess the feasibility of the proposed approach, highlight the characteristics of the technique and outline calibration strategies. Good agreement between imposed and measured flow rates was achieved leading to experimentation with live silver birch and oak (Quercus robur L.) saplings. It was demonstrated that water flow through xylem vessels can be monitored non-invasively on an intact stem with satisfactory accuracy despite simultaneous sugar transport in the phloem. In addition, it was demonstrated that the technique allows for unequivocal detection of phloem flow velocities.
引用
收藏
页码:169 / 179
页数:11
相关论文
共 28 条
  • [1] A laser-diode-based system for measuring sap flow by the heat-pulse method
    Bauerle, WL
    Whitlow, TH
    Pollock, CR
    Frongillo, EA
    [J]. AGRICULTURAL AND FOREST METEOROLOGY, 2002, 110 (04) : 275 - 284
  • [2] CANNY MJP, 1975, ENCY PLANT PHYSL, P139
  • [3] Closs R. L., 1958, New Zealand Journal of Science, V1, P281
  • [4] CALIBRATED HEAT PULSE METHOD FOR DETERMINING WATER-UPTAKE IN COTTON
    COHEN, Y
    FUCHS, M
    FALKENFLUG, V
    MORESHET, S
    [J]. AGRONOMY JOURNAL, 1988, 80 (03) : 398 - 402
  • [5] IMPROVEMENT OF THE HEAT PULSE METHOD FOR DETERMINING SAP FLOW IN TREES
    COHEN, Y
    FUCHS, M
    GREEN, GC
    [J]. PLANT CELL AND ENVIRONMENT, 1981, 4 (05) : 391 - 397
  • [6] Validating sap flow measurement in field-grown sunflower and corn
    Cohen, Y
    Li, Y
    [J]. JOURNAL OF EXPERIMENTAL BOTANY, 1996, 47 (304) : 1699 - 1707
  • [7] DIXON A, 1975, ENCY PLANT PHYSL, P154
  • [8] SAP FLOW MEASUREMENTS OF TRANSPIRATION FROM COTTON GROWN UNDER AMBIENT AND ENRICHED CO2 CONCENTRATIONS
    DUGAS, WA
    HEUER, ML
    HUNSAKER, D
    KIMBALL, BA
    LEWIN, KF
    NAGY, J
    JOHNSON, M
    [J]. AGRICULTURAL AND FOREST METEOROLOGY, 1994, 70 (1-4) : 231 - 245
  • [9] Evaluation of the heat pulse velocity method for measuring sap flow in Pinus patula
    Dye, PJ
    Soko, S
    Poulter, AG
    [J]. JOURNAL OF EXPERIMENTAL BOTANY, 1996, 47 (300) : 975 - 981
  • [10] Heat-pulse measurements of sap flow in olives for automating irrigation:: tests, root flow and diagnostics of water stress
    Fernández, JE
    Palomo, MJ
    Díaz-Espejo, A
    Clothier, BE
    Green, SR
    Girón, IF
    Moreno, F
    [J]. AGRICULTURAL WATER MANAGEMENT, 2001, 51 (02) : 99 - 123