Results at a minimum follow-up of 5 years of a ligaments-compatible total ankle replacement design

被引:14
作者
Giannini, Sandro [1 ]
Romagnoli, Matteo [2 ]
Barbadoro, Paolo [1 ]
Muccioli, Giulio Maria Marcheggiani [2 ]
Cadossi, Matteo [1 ]
Grassi, Alberto [2 ]
Zaffagnini, Stefano [2 ]
机构
[1] Ist Ortoped Rizzoli, Dept Orthopaed Surg, Bologna, Italy
[2] Ist Ortoped Rizzoli, Dept Orthopaed Surg, Dipartimento Rizzoli Sicilia, SS 113,Km 246, I-90011 Bagheria, Italy
关键词
Ankle; Replacement; Arthritis; Trauma; LONG-TERM; ARTHROPLASTY; RATES; OSTEOARTHRITIS; COMPLICATIONS; ARTHRODESIS; MOBILITY; MOTION; RANGE;
D O I
10.1016/j.fas.2017.03.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: A new design of 3-part ankle replacement was developed to achieve compatibility with the natural ligaments by allowing certain fibers to remain isometric during passive motion. Methods: We evaluate 75 ankle prostheses implanted from July 2003 to December 2008, at a mean follow-up 6.5 +/- 1.1 years ( range 5-9 years). The mean age at surgery was 62 +/- 13 years ( range 29-82). Results: The mean AOFAS scores achieved at pre-op and at last follow-up were respectively 37 +/- 5 ( 23-45) and 78 +/- 8 ( 64-98). ( p < 0.001). Clinical range of motion of the ankle measured by goniometer pre op was 1 degrees +/- 2 of dorsiflexion and 12 degrees +/- 4 degrees of plantarflexion; at last follow- up range of motion increased to 6 degrees +/- 5 degrees in dorsiflexion ( p < 0.01) and 18 degrees +/- 7 degrees in plantarflexion ( p < 0.05). Radiographs showed no loosening and little signs of radiolucency. Two revisions necessitated component removal, neither for implant loosening. The overall survival rate was 97.3%. Conclusions: Function and Range-of-motion showed significant improvements. These results demonstrate that ligaments-compatible shaped talar and tibial components, with a fully conforming interposed meniscal bearing, can provide satisfactory survival rates and clinical outcomes in the middle term. (C) 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:116 / 121
页数:6
相关论文
共 56 条
[1]   Uncemented STAR total ankle prostheses -: Three to eight-year follow-up of fifty-one consecutive ankles [J].
Anderson, T ;
Montgomery, F ;
Carlsson, Å .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (07) :1321-1329
[2]  
Australian Orthopaedic Association, National Joint Replacement Registry Annual Report
[3]   Total Ankle Replacement Survival Rates Based on Kaplan-Meier Survival Analysis of National Joint Registry Data [J].
Bartel, Annette F. P. ;
Roukis, Thomas S. .
CLINICS IN PODIATRIC MEDICINE AND SURGERY, 2015, 32 (04) :483-+
[4]  
Bauer G., 1996, Foot and Ankle Surgery, V2, P119, DOI DOI 10.1046/j.1460-9584.1996.00024.x
[5]  
Bianchi A, 2013, BONE JOINT J B, V95, P793
[6]   Midterm results of the Salto Total Ankle prosthesis [J].
Bonnin, M ;
Judet, T ;
Colombier, JA ;
Buscayret, F ;
Graveleau, N ;
Piriou, P .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (424) :6-18
[7]   Ten-year evaluation of cementless Buechel-Pappas meniscal bearing total ankle replacement [J].
Buechel, FF ;
Buechel, FF ;
Pappas, MJ .
FOOT & ANKLE INTERNATIONAL, 2003, 24 (06) :462-472
[8]   Osteoarthritis of the ankle: The role of arthroplasty [J].
Chou, Loretta B. ;
Coughlin, Michael T. ;
Hansen, Sigvard, Jr. ;
Haskell, Andrew ;
Lundeen, Gregg ;
Saltzman, Charles L. ;
Mann, Roger A. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2008, 16 (05) :249-259
[9]   Accurate measurement of ankle range of motion after total ankle arthroplasty [J].
Coetzee, JC ;
Castro, MD .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (424) :27-31
[10]  
Conti SF, 2001, CLIN ORTHOP RELAT R, P105