An algorithm to improve the accuracy of search boundaries for objects obtained in the X-ray

被引:2
|
作者
Semenishchev, Evgenii [1 ,2 ]
Voronin, Viacheslav [1 ,2 ]
Zelensky, Aleksandr [1 ]
Shraifel, Igor [2 ]
Balabaeva, Oksana [2 ]
机构
[1] Moscow State Tech Univ STANKIN, Moscow 127055, Russia
[2] Don State Tech Univ, Rostov Na Donu, Russia
来源
ANOMALY DETECTION AND IMAGING WITH X-RAYS (ADIX) IV | 2019年 / 10999卷
关键词
denoising; image smoothing; image; edge detectors; density;
D O I
10.1117/12.2519544
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The paper proposes an algorithm to improve the accuracy of searching the boundaries of objects. We analyze X-ray images. Most often, images obtained in the X-ray range are subject to distortion. Noise and blurring are caused by the nature of the source and the imperfection of the sensor. In our work, we propose the use of a multicomponent processing algorithm. This type of processing is based on step-by-step image analysis. At the first stage, the stage of image blur recovery is performed (deblurring). At the next stage, the operation of filtering images (denoising) and processing the boundaries of objects is performed. The first two steps are performed using adaptive local processing with nonoverlapping windows. At the next stage, the multicriteria processing method is used for the one-dimensional and two-dimensional signals. The first approach is used to reduce the effect of the noise component at the boundaries of objects and is also used as a boundary detector. The second criterion is used to reduce the effect of the noise component in locally stationary areas. The efficiency of the proposed algorithm is shown using the example of medical X-ray data processing and the results of computed tomography. Using the example of the developed software for the analysis of CT images and the restoration of the lost elements of the bone structure, an example of the application of the proposed approaches for performing primary data processing operations is shown.
引用
收藏
页数:9
相关论文
共 36 条
  • [1] Dual-Energy Processing of X-ray Images of Beryl in Muscovite Obtained Using Pulsed X-ray Sources
    Komarskiy, Alexander
    Korzhenevskiy, Sergey
    Ponomarev, Andrey
    Chepusov, Alexander
    SENSORS, 2023, 23 (09)
  • [2] APPLICATION OF A DUAL-ENERGY MONOCHROMATIC X-RAY CT ALGORITHM TO POLYCHROMATIC X-RAY CT: A FEASIBILITY STUDY
    Chang, S.
    Lee, H. K.
    Cho, G.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2012, 44 (01) : 61 - 70
  • [3] MORPHOLOGY OF GRAPHITE AGGLOMERATES OBTAINED BY SPHERICAL AGGLOMERATION VIA PROPAGATION-BASED X-RAY MICROTOMOGRAPHY
    Schreier, Julia
    Broeckel, Ulrich
    IMAGE ANALYSIS & STEREOLOGY, 2024, 43 (01) : 85 - 95
  • [4] Identification of materials in X-Ray inspections of objects by the dual-energy method
    Osipov, S. P.
    Udod, V. A.
    Wang, Y.
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2017, 53 (08) : 568 - 587
  • [5] X-ray spectroscopy study of lithiated graphite obtained by thermal deposition of lithium
    Lapteva, L. L.
    Fedoseeva, Yu. V.
    Gevko, P. N.
    Smirnov, D. A.
    Gusel'nikov, A. V.
    Bulusheva, L. G.
    Okotrub, A. V.
    JOURNAL OF STRUCTURAL CHEMISTRY, 2017, 58 (06) : 1173 - 1179
  • [6] Features of X-ray Absorption Densitometry of Large-size Objects with Variable Thickness
    Osipov, S.
    Chakhlov, S.
    Osipov, O.
    Badin, S.
    Abashkin, A.
    III ALL-RUSSIAN SCIENTIFIC AND PRACTICAL CONFERENCE ON INNOVATIONS IN NON-DESTRUCTIVE TESTING (SIBTEST 2015), 2016, 671
  • [7] 3-D Visualization of X-ray Objects Using Stereo Line Sensors
    Hwang, Younggwan
    Lee, Namho
    Baek, Seung-Hae
    Park, Soon-Yong
    Park, Jong-Won
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (02) : 1422 - 1425
  • [8] Search for traversable wormholes in active galactic nuclei using x-ray data
    Tripathi, Ashutosh
    Zhou, Biao
    Abdikamalov, Askar B.
    Ayzenberg, Dimitry
    Bambi, Cosimo
    PHYSICAL REVIEW D, 2020, 101 (06)
  • [9] Improving the spatial and statistical accuracy in X-ray Raman scattering based direct tomography
    Sahle, Ch J.
    Mirone, A.
    Vincent, T.
    Kallonen, A.
    Huotari, S.
    JOURNAL OF SYNCHROTRON RADIATION, 2017, 24 : 476 - 481
  • [10] Automated registration of diagnostic to prediagnostic x-ray mammograms: Evaluation and comparison to radiologists' accuracy
    Pereira, Snehal M. Pinto
    Hipwell, John H.
    McCormack, Valerie A.
    Tanner, Christine
    Moss, Sue M.
    Wilkinson, Louise S.
    Khoo, Lisanne A. L.
    Pagliari, Catriona
    Skippage, Pippa L.
    Kliger, Carole J.
    Hawkes, David J.
    Silva, Isabel M. dos Santos
    MEDICAL PHYSICS, 2010, 37 (09) : 4530 - 4539