Factors Influencing the Accuracy of Freehand Implant Placement: A Prospective Clinical Study

被引:25
作者
Schnutenhaus, Sigmar [1 ,2 ]
Wagner, Marie [2 ]
Edelmann, Cornelia [1 ]
Luthardt, Ralph G. [2 ]
Rudolph, Heike [2 ]
机构
[1] Dr Schnutenhaus MVZ GmbH, Ctr Dent, D-78247 Hilzingen, Germany
[2] Ulm Univ, Ctr Dent, Dept Prosthet Dent, D-89081 Ulm, Germany
关键词
accuracy; computer-assisted surgery; computer-guided surgery; cone-beam computed tomography; dental implant; freehand; MENTAL NAVIGATION; GUIDED SURGERY; DENTISTRY; ANTERIOR; TRIAL; BONE;
D O I
10.3390/dj9050054
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
(1) Background: The objective of implant prosthetic restoration is to ensure the best possible rehabilitation of function and esthetics. Optimal positioning of the implant with regard to the bone availability, surrounding soft tissue, and prosthetic sustainability should be strived for during implant placement. The factors influencing freehand implant placement and the accuracy achieved with this procedure are investigated in this prospective clinical study. (2) Methods: Implants were placed in the single-tooth edentulous sites of the premolar and molar areas in 52 patients. Three-dimensional (3D)-planning was performed virtually prior to the freehand implant operation, and the desired position of the implant was provided to the surgeon. (3) Results: The deviations between the planned and the actually achieved position with freehand implant placement showed the following mean values and standard deviations: angle 8.7 +/- 4.8 degrees, 3D deviation at the implant shoulder 1.62 +/- 0.87 mm, mesiodistal deviation 0.87 +/- 0.75 mm, buccolingual deviation 0.70 +/- 0.66 mm, and apiocoronal deviation 0.95 +/- 0.61 mm. The type of jaw had a significant influence on accuracy. Major deviations were observed in the lower jaw. Furthermore, the timing of implant placement influenced the mesiodistal deviation and angular deviation; (4) Conclusions: Freehand implant placement demonstrated a higher level of deviation between the planned and actually achieved implant positions. In particular, the ranges showed a large spread. From a prosthetic point of view, there may be complications during the restoration of the prosthetic crown if the implant exit point is not optimally located or if the implants show a high angular deviation.
引用
收藏
页数:12
相关论文
共 36 条
[1]   Accuracy of static computer-assisted implant placement in anterior and posterior sites by clinicians new to implant dentistry: in vitro comparison of fully guided, pilot-guided, and freehand protocols [J].
Abduo, Jaafar ;
Lau, Douglas .
INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
[2]   Implant Positioning Errors in Freehand and Computer-Aided Placement Methods: A Single-Blind Clinical Comparative Study [J].
Arisan, Volkan ;
Karabuda, Cueneyt Z. ;
Mumcu, Emre ;
Oezdemir, Tayfun .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (01) :190-204
[3]   Accuracy of dental implant placement via dynamic navigation or the freehand method: A split-mouth randomized controlled clinical trial [J].
Aydemir, Ceyda Aktolun ;
Arisan, Volkan .
CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (03) :255-263
[4]   Digital vs. Freehand Anterior Single-Tooth Implant Restoration [J].
Baldi, D. ;
Colombo, J. ;
Motta, F. ;
Motta, F. M. ;
Zillio, A. ;
Scotti, N. .
BIOMED RESEARCH INTERNATIONAL, 2020, 2020
[5]   Factors influencing transfer accuracy of cone beam CT-derived template-based implant placement [J].
Behneke, Alexandra ;
Burwinkel, Matthias ;
Behneke, Nikolaus .
CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (04) :416-423
[6]   A randomized controlled clinical trial comparing guided with nonguided implant placement: A 3-year follow-up of implant-centered outcomes [J].
Bernard, Lauren ;
Vercruyssen, Marjolein ;
Duyck, Joke ;
Jacobs, Reinhilde ;
Teughels, Wim ;
Quirynen, Marc .
JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (06) :904-910
[7]   Digital Smile Designed Computer-Aided Surgery versus Traditional Workflow in "All on Four" Rehabilitations: A Randomized Clinical Trial with 4-Years Follow-Up [J].
Cattoni, Francesca ;
Chirico, Luca ;
Merlone, Alberto ;
Manacorda, Michele ;
Vinci, Raffaele ;
Gherlone, Enrico Felice .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (07)
[8]   Accuracy of Implant Placement with a Navigation System, a Laboratory Guide, and Freehand Drilling [J].
Chen, Chang-Kai ;
Yuh, Da-Yo ;
Huang, Ren-Yeong ;
Fu, Earl ;
Tsai, Cheng-Feng ;
Chiang, Cheng-Yang .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (06) :1213-1218
[9]   Accuracy of flapless immediate implant placement in anterior maxilla using computer-assisted versus freehand surgery: A cadaver study [J].
Chen, Zhaozhao ;
Li, Junying ;
Sinjab, Khaled ;
Mendonca, Gustavo ;
Yu, Haiyang ;
Wang, Hom-Lay .
CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (12) :1186-1194
[10]   Freehand Versus Guided Surgery: Factors Influencing Accuracy of Dental Implant Placement [J].
Choi, William ;
Nguyen, Bao-Chau ;
Doan, Andrew ;
Girod, Sabine ;
Gaudilliere, Brice ;
Gaudilliere, Dyani .
IMPLANT DENTISTRY, 2017, 26 (04) :500-509