Study on Ablation between Metal Sheath and Buffer Layer of High Voltage XLPE Insulated Power Cable

被引:0
|
作者
Jiang, Lei [1 ]
Xin, Yue [1 ]
Yan, Wenbo [1 ]
Zhao, Xiyuan [1 ]
Yao, Ruifeng [1 ]
Shen, Zhuoyuan [1 ]
Gao, Jinghui [1 ]
Zhong, Lisheng [1 ]
Wald, Detlef F. [2 ]
Ren, Zhigang [3 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, IEEE Conf Publishing, Xian 710049, Shaanxi, Peoples R China
[2] Eifelkabel Consultant Co, CH-5612 Villmergen, Switzerland
[3] State Grid Beijing Elect Power Res Inst, Beijing 100075, Peoples R China
来源
2019 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL MATERIALS AND POWER EQUIPMENT (ICEMPE 2019) | 2019年
关键词
DEGRADATION;
D O I
10.1109/icempe.2019.8727342
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The corrugation aluminum (Al) is a common sheath structure of high voltage cross-linked polyethylene (XLPE) insulated cable in China due to its good bending performance. However, some problems, especially buffer layer ablation, have occurred frequently in cables due to such corrugated structure. At present, the causes of ablation are unclear, which makes it difficult to prevent relevant accidents. This paper aims at studying the possible causes of ablation by means of reproducing ablation in the laboratory. In the process of investigating ablation on failure cable, it is found that the Al sheath has some burnt stains, which is similar to discharge traces. From the discharge consideration, simulation method and actual experiments are carried out by a model sample built by an arc-shaped Al electrode system as well as a buffer layer to imitate the corrugated sheath structure in HV cable. The simulation result shows that when there is a bad contact between the Al sheath and buffer layer, the discharge will occur. Moreover, it is indicated by the experiment that the inception voltage of discharging will become higher with the increase of the electrode interval. Some further studies are carried out around the ablation morphology. The morphology of the ablated buffer layer from laboratory is observed by optical-microscopic, which shows great similarity with the ablation points in failure cables, verifying discharge is one of the causes of ablation.
引用
收藏
页码:372 / 375
页数:4
相关论文
共 50 条
  • [1] Study on the ablation process and failure mechanism of the buffer layer in high-voltage XLPE cable
    Tian, Yi
    Zhu, Guixin
    Miao, Qingqing
    Huang, Jiasheng
    Huang, Xinbo
    Li, Shengtao
    Li, Licheng
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2024, 19 (08):
  • [2] Laminate sheath power cable insulated with XLPE for flame retardant applications
    Bow, K.E.
    REE, Revue de L'Electricite et de L'Electronique, 2003, 2003 (6-7): : 37 - 41
  • [3] Generation Characteristics of White Powder on the Buffer Layer of XLPE High Voltage Cable
    He, Yongxin
    Ji, Shangchen
    Liu, Yumeng
    Li, Yuan
    2024 IEEE 2ND INTERNATIONAL CONFERENCE ON POWER SCIENCE AND TECHNOLOGY, ICPST 2024, 2024, : 420 - 425
  • [4] A New Insight into Discharge Ablation Mechanism of Buffer Layer in High Voltage Power Cable
    Xie, Yi
    Ouyang, Zelun
    Wang, Jun
    Cao, Xianhui
    Zhong, Zhen
    Wu, Tangqing
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2024,
  • [5] Analysis of influencing factors on buffer layer discharge for high-voltage XLPE cable
    Wu, Zhiheng
    Lai, Qingbo
    Zhou, Wenqing
    Liu, Xiaodong
    Chen, Jie
    Hu, Libin
    Hao, Yanpeng
    Liu, Gang
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2022, 16 (20) : 4142 - 4157
  • [6] Ablative Properties of Buffer Layer in Aluminum Sheath Structure of High Voltage Cable
    Feng Y.
    Deng X.
    Li W.
    Zhao J.
    Wang A.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (12): : 4919 - 4928
  • [7] DEVELOPMENT OF XLPE-MOULDED JOINT FOR HIGH-VOLTAGE XLPE INSULATED CABLE
    OHATA, K
    KOJIMA, H
    SHIMOMURA, T
    ASAHI, K
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1983, 102 (07): : 1935 - 1941
  • [8] Distributed Optical Fiber Detection Based on BOTDR for Buffer Layer Defects of High-Voltage XLPE Cable With Corrugated Aluminum Sheath
    Cheng, Yanting
    Hao, Yanpeng
    Tian, Wanxing
    Zhao, Peng
    Tan, Haotian
    Li, Qishun
    Li, Licheng
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (04) : 1778 - 1787
  • [9] Effects of connection conditions between insulation screen and Al sheath on the buffer layer failures of high-voltage XLPE cables
    Chen, Yun
    Hui, Baojun
    Cheng, Yanting
    Chen, Yanwen
    Hao, Yanpeng
    Fu, Mingli
    Yang, Lin
    Li, Licheng
    ENGINEERING FAILURE ANALYSIS, 2021, 122
  • [10] Analysis for metal sheath corrosion rate in AC high voltage power cable
    Lai, Lin-Hua
    Wu, Zhi-Heng
    Liu, Xiao-Dong
    Hao, Yanpeng
    Liu, Gang
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2022, 16 (22) : 4563 - 4574