An experimental study of loaded full-scale cold-formed thin-walled steel structural panels under fire conditions

被引:79
作者
Feng, M
Wang, YC
机构
[1] UMIST, Manchester Ctr Civil & Construct Engn, Manchester M60 1QD, Lancs, England
[2] Univ Manchester, Manchester M60 1QD, Lancs, England
基金
英国工程与自然科学研究理事会;
关键词
cold-formed steel; thin-walled steel structural panel; gypsum plasterboard; thermal bowing; fire test; fire resistance; temperature distribution;
D O I
10.1016/j.firesaf.2004.08.002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the results of eight tests on loaded full-scale cold-formed thin-walled steel structural panels, two tests at ambient temperature and six exposed to the standard fife condition on one side. The test panels used two types of tipped channels. 100 x 54 x 15 x 1.2 mm or 100 x 54 x 15 x 2 mm. each channel having two service holes, one near the top and one near the bottom. Three different load levels, being 0.2. 0.4 and 0.1 times the load carrying capacity of the same panel tested at ambient temperature, were applied during the six fire tests. At ambient temperature, failure was local buckling around the top service hole. Under fire condition. the main failure mode was overall flexural-torsional buckling about the major axis. with the lateral deformations of the test panels being mainly caused by thermal bowing due to temperature gradients. The interior insulation in some tests was burnt through and this had noticeable influence on temperature developments in the test steel channels. In two fire tests using the thinner channels. the test panels failed before 30 min that is considered to be the minimum standard fire rating of this type of construction. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:43 / 63
页数:21
相关论文
共 14 条
[1]  
*AISI, 1986, SPEC DES COLD FORM S
[2]  
ALFAWAKHIRI F, 2001, P FIR MAT 2001 C, P483
[3]  
ANG CN, 2003, IN PRESS FIRE MAT
[4]   Axial strength of cold-formed thin-walled steel channels under non-uniform temperatures in fire [J].
Feng, M ;
Wang, YC ;
Davies, JM .
FIRE SAFETY JOURNAL, 2003, 38 (08) :679-707
[5]   Thermal performance of cold-formed thin-walled steel panel systems in fire [J].
Feng, M ;
Wang, YC ;
Davies, JM .
FIRE SAFETY JOURNAL, 2003, 38 (04) :365-394
[6]   Structural behaviour of cold-formed thin-walled short steel channel columns at elevated temperatures. Part 2: Design calculations and numerical analysis [J].
Feng, M ;
Wang, YC ;
Davies, TM .
THIN-WALLED STRUCTURES, 2003, 41 (06) :571-594
[7]   Structural behaviour of cold-formed thin-walled short steel channel columns at plevated temperatures. Part 1: experiments [J].
Feng, M ;
Wang, YC ;
Davies, JM .
THIN-WALLED STRUCTURES, 2003, 41 (06) :543-570
[8]  
Feng M., 2004, THESIS U MANCHESTER
[9]  
Gerlich JT, 1995, 953 FIR ENG RES
[10]  
KESTI J, 1998, J CONSTRUCT STEEL RE, V46