Effect of apex angle variation on thermal and hydraulic performance of roughened triangular duct

被引:27
作者
Goel, Varun [1 ]
Guleria, Pankaj [2 ]
Kumar, Rajneesh [1 ]
机构
[1] Natl Inst Technol, Hamirpur 177005, HP, India
[2] Bhushan Steels, Dhenkanal, Orissa, India
关键词
Apex angle; Dimple shaped roughness; Triangular duct; Correlation; HEAT-TRANSFER; FORCED-CONVECTION; FRICTION CHARACTERISTICS; FLOW-THROUGH; ROUGHNESS ELEMENT; PRESSURE-DROP; LAMINAR;
D O I
10.1016/j.icheatmasstransfer.2017.06.008
中图分类号
O414.1 [热力学];
学科分类号
摘要
The experiments were performed to analyze the influence of apex angle on thermal and hydraulic characteristics of triangular duct for Reynolds number range from 2000 to 16,000. Four different triangular ducts of apex angle 30 degrees, 60 degrees, 90 degrees and 110 degrees were fabricated for the experimentation. The one side of the duct is roughened with dimple shaped roughness element. The both relative shortway length (s/e) and relative longway length (l/e) of dimple shaped roughened element was kept constant (i.e., 10) but relative roughness height (e/D) is varied from 0.016 to 0.038. Result shows that apex angle plays an important role in heat transfer. The experimental results are presented in a form of correlation for Nusselt number (Nu) and friction factor (f).