On-line monitoring of lung mechanics during spontaneous breathing: a physiological study

被引:24
作者
Khirani, Sonia
Polese, Guido
Aliverti, Andrea [2 ]
Appendini, Lorenzo [3 ]
Nucci, Gianluca [4 ]
Pedotti, Antonio [2 ]
Colledan, Michele [5 ]
Lucianetti, Alessandro [5 ]
Baconnier, Pierre [6 ]
Rossi, Andrea [1 ]
机构
[1] Osped Riuniti Bergamo, USC, Pulm Div AO, I-24128 Bergamo, Italy
[2] Politecn Milan, Bioengn Unit, Milan, Italy
[3] IRCCS Rehabil Inst Veruno, Salvatore Maugeri Fdn, Veruno, Italy
[4] Pfizer Global Res & Dev, New London, CT USA
[5] AO Osped Riuniti Bergamo, Gen Surg Liver & Lung Transplantat Ctr 3, Bergamo, Italy
[6] Univ Grenoble 1, CNRS, Lab TIMC IMAG, UMR 5525, Grenoble, France
关键词
Cystic Fibrosis; COPD; Lung transplantation; Lung mechanics; On-line monitoring; Spontaneous breathing; Esophageal catheter-balloon; END-EXPIRATORY PRESSURE; OBSTRUCTIVE PULMONARY-DISEASE; RESPIRATORY-DISTRESS-SYNDROME; DYNAMIC HYPERINFLATION; CYSTIC-FIBROSIS; FLOW LIMITATION; STABLE PATIENTS; TRANSPLANTATION; VENTILATION; PARAMETERS;
D O I
10.1016/j.rmed.2009.09.014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Monitoring the mechanics of breathing in patients with advanced chronic obstructive lung diseases prior to lung transplantation is useful to characterize changes in the mechanical properties of the lungs. On-line methods of monitoring immediately process the data for clinical decisions. However, the few available methods are so far limited to monitor respiratory mechanics in ventilator-dependent patients. We investigated whether on-line monitoring of the lung mechanics, including intrinsic PEEP, was feasible in spontaneously breathing patients. Methods: In 9 stable patients with chronic obstructive pulmonary disease (COPD) and 11 with cystic fibrosis (CF) undergoing the procedure for the lung transplantation waiting list, we applied 2 methods of on-line monitoring (modified recursive least squares, RLS and modified multiple linear regression methods, SLS) of intrinsic PEEP (P-0), dynamic lung elastance (E-Ldyn) and inspiratory resistance (R-Linsp), and compared them with an off-line graphical analysis (GA), our reference technique. Results: In CF patients, there was no difference between methods, white in COPD, the median values of E-Ldyn and R-Linsp were significantly different between GA/SLS and GA/RLS, respectively (Dunn's, p 0.05). However, the correlation was very high for all comparisons, particularly for E-Ldyn (R > 0.98) and R-Linsp (R > 0.93). Moreover, Bland-Altman plots showed that the mean differences were consistently tow and the intervals of agreement reasonable. Conclusions: Our study suggests that on-tine methods are reliable for monitoring lung mechanics in spontaneous breathing patients with severe lung diseases and could help clinicians in their decision-making process. (C) 2009 Published by Elsevier Ltd.
引用
收藏
页码:463 / 471
页数:9
相关论文
共 51 条
  • [1] Partitioning of inspiratory muscle workload and pressure assistance in ventilator-dependent COPD patients
    Appendini, L
    Purro, A
    Patessio, A
    Zanaboni, S
    Carone, M
    Spada, E
    Donner, CF
    Rossi, A
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 154 (05) : 1301 - 1309
  • [2] Appendini L, 2001, Curr Opin Crit Care, V7, P41, DOI 10.1097/00075198-200102000-00007
  • [3] PHYSIOLOGICAL-EFFECTS OF POSITIVE END-EXPIRATORY PRESSURE AND MASK PRESSURE SUPPORT DURING EXACERBATIONS OF CHRONIC OBSTRUCTIVE PULMONARY-DISEASE
    APPENDINI, L
    PATESSIO, A
    ZANABONI, S
    CARONE, M
    GUKOV, B
    DONNER, CF
    ROSSI, A
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 149 (05) : 1069 - 1076
  • [4] REAL-TIME TRACKING OF PARAMETERS OF LUNG-MECHANICS - EMPHASIS ON ALGORITHM TUNING
    AVANZOLINI, G
    BARBINI, P
    CAPPELLO, A
    CEVENINI, G
    [J]. JOURNAL OF BIOMEDICAL ENGINEERING, 1990, 12 (06): : 489 - 495
  • [5] A NONSTATISTICAL APPROACH TO ESTIMATING CONFIDENCE-INTERVALS ABOUT MODEL PARAMETERS - APPLICATION TO RESPIRATORY MECHANICS
    BATES, JHT
    LAUZON, AM
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (01) : 94 - 100
  • [6] BAYDUR A, 1982, AM REV RESPIR DIS, V126, P788
  • [7] The Italian multicentre study on noninvasive ventilation in chronic obstructive pulmonary disease patients
    Clini, E
    Sturani, C
    Rossi, A
    Viaggi, S
    Corrado, A
    Donner, CF
    Ambrosino, N
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2002, 20 (03) : 529 - 538
  • [8] DALVECCHIO L, 1990, EUR RESPIR J, V3, P74
  • [9] Novel aspects of pulmonary mechanics in intensive care
    de Chazal, I
    Hubmayr, RD
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2003, 91 (01) : 81 - 91
  • [10] A program based on a 'selective' least-squares method for respiratory mechanics monitoring in ventilated patients
    Eberhard, A
    Carry, PY
    Perdrix, JP
    Fargnoli, JM
    Biot, L
    Baconnier, PF
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2003, 71 (01) : 39 - 61