Implementation of an enclosed ionization interface for the analysis of liquid sample streams with direct analysis in real time mass spectrometry

被引:7
作者
Kloth, Ricarda [1 ,2 ]
Khanipour, Peyman [1 ,2 ]
Mayrhofer, Karl J. J. [1 ,2 ]
Katsounaros, Ioannis [1 ]
机构
[1] Forschungszentrum Julich, Helmholtz Inst Erlangen Nurnberg Renewable Energy, Egerlandstr 3, D-91058 Erlangen, Germany
[2] Friedrich Alexander Univ Erlangen Nurnberg, Dept Chem & Biol Engn, Egerlandstr 3, D-91058 Erlangen, Germany
关键词
ION-SOURCE; NONPOLAR COMPOUNDS; CHROMATOGRAPHY; ALCOHOLS; MS;
D O I
10.1002/rcm.9091
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale The development of an interface to analyze liquid sample streams with direct analysis in real time mass spectrometry (DART-MS) is of great interest for coupling various analytical techniques, using non-volatile salts, with MS. Therefore, we devised an enclosed ionization interface and a sample introduction system for the versatile analysis of liquid samples with DART-MS. Methods The sample introduction system consists of a nebulizer, a spray chamber and a transfer line, while the confined ionization interface is created by implementing a cross-shaped housing between ion source outlet and mass spectrometer inlet. Methodical studies of the effects of various setup parameters on signal intensity and peak shape were conducted, while its diverse applicability was demonstrated by coupling with high-performance liquid chromatography (HPLC) for the analysis of alcohols, organic acids and furanic compounds. Results The confinement of the ionization interface results in a robust setup design with a well-defined ionization region for focusing of the sprayed sample mist. Thereby, an increase in analyte signal intensity by three orders of magnitude and improved signal stability and reproducibility were obtained in comparison with a similar open ionization interface configuration. Additionally, the successful quantification of alcohols could be demonstrated as well as the compatibility of the setup with HPLC gradient elution. Conclusions A versatile setup design for the analysis of liquid sample streams with DART-MS was devised for monitoring reactions or hyphenating analytics with MS. The design minimizes interferences from the laboratory surroundings as well as allows for safe handling of hazardous and toxic chemicals, which renders it suitable for a broad range of applications.
引用
收藏
页数:11
相关论文
共 50 条
[21]   Monitoring tea fermentation/manufacturing by direct analysis in real time (DART) mass spectrometry [J].
Fraser, Karl ;
Lane, Geoff A. ;
Otter, Don E. ;
Harrison, Scott J. ;
Quek, Siew-Young ;
Hemar, Yacine ;
Rasmussen, Susanne .
FOOD CHEMISTRY, 2013, 141 (03) :2060-2065
[22]   Analysis of printing and writing papers by using direct analysis in real time mass spectrometry [J].
Adams, Jeanette .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2011, 301 (1-3) :109-126
[23]   Direct Monitoring of the Role Played by a Stabilizer in a Solid Sample of Polymer Using Direct Analysis in Real Time Mass Spectrometry: The Case of lrgafos 168 in Polyethylene [J].
Fouyer, Kevin ;
Lavastre, Olivier ;
Rondeau, David .
ANALYTICAL CHEMISTRY, 2012, 84 (20) :8642-8649
[24]   Authentication of Animal Fats Using Direct Analysis in Real Time (DART) Ionization-Mass Spectrometry and Chemometric Tools [J].
Vaclavik, Lukas ;
Hrbek, Vojtech ;
Cajka, Tomas ;
Rohlik, Bo-Anne ;
Pipek, Petr ;
Hajslova, Jana .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2011, 59 (11) :5919-5926
[25]   Improvement in ionization efficiency of direct analysis in real time-mass spectrometry (DART-MS) by corona discharge [J].
Sekimoto, Kanako ;
Sakakura, Motoshi ;
Kawamukai, Takatomo ;
Hike, Hiroshi ;
Shiota, Teruhisa ;
Usui, Fumihiko ;
Bando, Yasuhiko ;
Takayama, Mitsuo .
ANALYST, 2016, 141 (16) :4879-4892
[26]   Capabilities and limitations of direct analysis in real time orbitrap mass spectrometry and tandem mass spectrometry for the analysis of synthetic and natural polymers [J].
Bridoux, Maxime C. ;
Machuron-Mandard, Xavier .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (18) :2057-2070
[27]   Direct Identification of Dyes in Textiles by Direct Analysis in Real Time-Time of Flight Mass Spectrometry [J].
DeRoo, Cathy Selvius ;
Armitage, Ruth Ann .
ANALYTICAL CHEMISTRY, 2011, 83 (18) :6924-6928
[28]   Identification of saccharides by using direct analysis in real time (DART) mass spectrometry [J].
Wang, Yang ;
Liu, Li ;
Ma, Li ;
Liu, Shuying .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2014, 357 :51-57
[29]   Differentiating writing inks using direct analysis in real time mass spectrometry [J].
Jones, RW ;
Cody, RB ;
McClelland, JF .
JOURNAL OF FORENSIC SCIENCES, 2006, 51 (04) :915-918
[30]   Rapid analysis of caffeine in various coffee samples employing direct analysis in real-time ionization-high-resolution mass spectrometry [J].
Danhelova, Hana ;
Hradecky, Jaromir ;
Prinosilova, Sarka ;
Cajka, Tomas ;
Riddellova, Katerina ;
Vaclavik, Lukas ;
Hajslova, Jana .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (10) :2883-2889