Implementation of an enclosed ionization interface for the analysis of liquid sample streams with direct analysis in real time mass spectrometry

被引:7
作者
Kloth, Ricarda [1 ,2 ]
Khanipour, Peyman [1 ,2 ]
Mayrhofer, Karl J. J. [1 ,2 ]
Katsounaros, Ioannis [1 ]
机构
[1] Forschungszentrum Julich, Helmholtz Inst Erlangen Nurnberg Renewable Energy, Egerlandstr 3, D-91058 Erlangen, Germany
[2] Friedrich Alexander Univ Erlangen Nurnberg, Dept Chem & Biol Engn, Egerlandstr 3, D-91058 Erlangen, Germany
关键词
ION-SOURCE; NONPOLAR COMPOUNDS; CHROMATOGRAPHY; ALCOHOLS; MS;
D O I
10.1002/rcm.9091
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale The development of an interface to analyze liquid sample streams with direct analysis in real time mass spectrometry (DART-MS) is of great interest for coupling various analytical techniques, using non-volatile salts, with MS. Therefore, we devised an enclosed ionization interface and a sample introduction system for the versatile analysis of liquid samples with DART-MS. Methods The sample introduction system consists of a nebulizer, a spray chamber and a transfer line, while the confined ionization interface is created by implementing a cross-shaped housing between ion source outlet and mass spectrometer inlet. Methodical studies of the effects of various setup parameters on signal intensity and peak shape were conducted, while its diverse applicability was demonstrated by coupling with high-performance liquid chromatography (HPLC) for the analysis of alcohols, organic acids and furanic compounds. Results The confinement of the ionization interface results in a robust setup design with a well-defined ionization region for focusing of the sprayed sample mist. Thereby, an increase in analyte signal intensity by three orders of magnitude and improved signal stability and reproducibility were obtained in comparison with a similar open ionization interface configuration. Additionally, the successful quantification of alcohols could be demonstrated as well as the compatibility of the setup with HPLC gradient elution. Conclusions A versatile setup design for the analysis of liquid sample streams with DART-MS was devised for monitoring reactions or hyphenating analytics with MS. The design minimizes interferences from the laboratory surroundings as well as allows for safe handling of hazardous and toxic chemicals, which renders it suitable for a broad range of applications.
引用
收藏
页数:11
相关论文
共 38 条
[1]   High-performance liquid chromatography coupled to direct analysis in real time mass spectrometry: Investigations on gradient elution and influence of complex matrices on signal intensities [J].
Beissmann, Susanne ;
Buchberger, Wolfgang ;
Hertsens, Robert ;
Klampfl, Christian W. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (31) :5180-5186
[2]   Online Coupling of Capillary Electrophoresis with Direct Analysis in Real Time Mass Spectrometry [J].
Chang, Cuilan ;
Xu, Gege ;
Bai, Yu ;
Zhang, Chengsen ;
Li, Xianjiang ;
Li, Min ;
Liu, Yi ;
Liu, Huwei .
ANALYTICAL CHEMISTRY, 2013, 85 (01) :170-176
[3]   Normal phase LC coupled with direct analysis in real time MS for the chiral analysis of 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol and jasmonic acid [J].
Chang, Cuilan ;
Zhou, Zhigui ;
Yang, Youyou ;
Han, Yehua ;
Bai, Yu ;
Zhao, Meiping ;
Liu, Huwei .
ELECTROPHORESIS, 2012, 33 (22) :3387-3393
[4]   Versatile new ion source for the analysis of materials in open air under ambient conditions [J].
Cody, RB ;
Laramée, JA ;
Durst, HD .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2297-2302
[5]   Thermal desorption and pyrolysis direct analysis in real time mass spectrometry for qualitative characterization of polymers and polymer additives [J].
Cody, Robert B. ;
Fouquet, Thierry N. J. ;
Takei, Chikako .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2020, 34
[6]  
Cody RB, 2015, NEW DEV NMR, P23
[7]   Soft Ionization of Saturated Hydrocarbons, Alcohols and Nonpolar Compounds by Negative-Ion Direct Analysis in Real-Time Mass Spectrometry [J].
Cody, Robert B. ;
Dane, A. John .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2013, 24 (03) :329-334
[8]   Observation of Molecular Ions and Analysis of Nonpolar Compounds with the Direct Analysis in Real Time Ion Source [J].
Cody, Robert B. .
ANALYTICAL CHEMISTRY, 2009, 81 (03) :1101-1107
[9]   Mass spectrometry detection in comprehensive liquid chromatography: Basic concepts, instrumental aspects, applications and trends [J].
Donato, Paola ;
Cacciola, Francesco ;
Tranchida, Peter Quinto ;
Dugo, Paola ;
Mondello, Luigi .
MASS SPECTROMETRY REVIEWS, 2012, 31 (05) :523-559
[10]   Investigations on the Coupling of High-Performance Liquid Chromatography to Direct Analysis in Real Time Mass Spectrometry [J].
Eberherr, Walter ;
Buchberger, Wolfgang ;
Hertsens, Robert ;
Klampfl, Christian W. .
ANALYTICAL CHEMISTRY, 2010, 82 (13) :5792-5796