Thirteen collision/reaction gases (CH4, O-2, H-2, CH3F, C2H6, N2O, NH3, SF6, Xe, Ne, N-2, CO and Ar) were investigated to reduce the ArAr+, Ar2H+, Ar2H2+, SeH+, BrH+ and ArCl+ overlaps on Se+ isotopes. N-2 and Ar had particular advantages for the measurement of multiple Se isotopes compared to the other gases. Experiments using CH4 and CD4 determined that H-atom transfer from CH4 to Se+ resulted in the formation of SeH+. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:197 / 210
页数:14
相关论文
共 75 条
[41]  
Lide D. R., 2006, CRC HDB CHEM PHYS
[42]  
MAHNERT J, 1995, J CHEM PHYS, V102, P180, DOI 10.1063/1.469389
[43]   Inorganic selenium speciation using HPLC-ICP-hexapole collision/reaction cell-MS [J].
Mazan, S ;
Gilon, N ;
Crétier, G ;
Rocca, JL ;
Mermet, JM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (04) :366-370
[44]   Analysis of total arsenic, total selenium and total chromium in urine by inductively coupled plasma-dynamic reaction cell-mass spectrometry [J].
McShane, William J. ;
Pappas, R. Steven ;
Paschal, Dan .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (06) :630-635
[45]   Selenium in Oncology: From Chemistry to Clinics [J].
Micke, Oliver ;
Schomburg, Lutz ;
Buentzel, Jens ;
Kisters, Klaus ;
Muecke, Ralph .
MOLECULES, 2009, 14 (10) :3975-3988
[46]   Determination of arsenic, iron and selenium in moss samples using hexapole collision cell, inductively coupled plasma-mass spectrometry [J].
Niemelä, M ;
Perämäki, P ;
Kola, H ;
Piispanen, J .
ANALYTICA CHIMICA ACTA, 2003, 493 (01) :3-12
[47]   Reduction of molecular ion interferences with hexapole collision cell in direct injection nebulization-inductively coupled plasma mass spectrometry [J].
O'Brien, SE ;
Acon, BW ;
Boulyga, SF ;
Becker, JS ;
Dietze, HJ ;
Montaser, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (03) :230-238
[48]   Effects of deuterium in octopole reaction and collision cell ICP-MS on detection of selenium in extracellular fluids [J].
Ogra, Y ;
Ishiwata, K ;
Suzuki, KT .
ANALYTICA CHIMICA ACTA, 2005, 554 (1-2) :123-129
[49]   Strategies to develop methods using ion-molecule reactions in a quadrupole reaction cell to overcome spectral overlaps in inductively coupled plasma mass spectrometry [J].
Olesik, JW ;
Jones, DR .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (02) :141-159
[50]   Analysis of the selenium species distribution in cow blood by size exclusion liquid chromatography-inductively coupled plasma collision cell mass spectrometry (SEC-ICPccMS) [J].
Palacios, O ;
Encinar, JR ;
Bertin, G ;
Lobinski, R .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (03) :516-522