The Oxford Sleep Resistance test (OSLER) and the Multiple Unprepared Reaction Time Test (MURT) Detect Vigilance Modifications in Sleep Apnea Patients

被引:18
作者
Alakuijala, Anniina [1 ,2 ]
Maasilta, Paula [3 ]
Bachour, Adel [3 ]
机构
[1] Univ Helsinki, Cent Hosp, HUS Med Imaging Ctr, Dept Clin Neurophysiol, FI-00029 Helsinki, Finland
[2] Univ Helsinki, Dept Neurol Sci, Helsinki, Finland
[3] Univ Helsinki, Cent Hosp, Dept Pulm, Sleep Unit, FI-00029 Helsinki, Finland
来源
JOURNAL OF CLINICAL SLEEP MEDICINE | 2014年 / 10卷 / 10期
关键词
vigilance; alertness; CPAP; excessive daytime sleepiness; reaction time; EXCESSIVE DAYTIME SLEEPINESS; RANDOMIZED CONTROLLED-TRIAL; WAKEFULNESS TEST; SUSTAINED ATTENTION; BEHAVIORAL-TEST; PRESSURE; MAINTENANCE; VALIDATION; CPAP; HOME;
D O I
10.5664/jcsm.4104
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Objectives: The Oxford Sleep Resistance Test (OSLER) is a behavioral test that measures a subject's ability to maintain wakefulness and assesses daytime vigilance. The multiple unprepared reaction time (MURT) test measures a subject's reaction time in response to a series of visual or audible stimuli. Methods: We recruited 34 healthy controls in order to determine the normative data for MURT. Then we evaluated modifications in OSLER and MURT values in 192 patients who were referred for suspicion of sleep apnea. We performed OSLER (three 40-min sessions) and MURT (two 10-min sessions) tests at baseline. Of 173 treated OSA patients, 29 professional drivers were retested within six months of treatment. Results: MURT values above 250 ms can be considered abnormal. The OSLER error index (the number of all errors divided by the duration of the session in hours) correlated statistically significantly with sleep latency, MURT time, and ESS. Treatment improved OSLER sleep latency from 33 min 4 s to 36 min 48 s, OSLER error index from 66/h to 26/h, and MURT time from 278 ms to 224 ms; these differences were statistically significant. Conclusions: OSLER and MURT tests are practical and reliable tools for measuring improvement in vigilance due to sleep apnea therapy in professional drivers.
引用
收藏
页码:1075 / 1082
页数:8
相关论文
共 35 条
[31]  
Sauter C, 2000, J SLEEP RES, V9, P293
[32]   Randomized Controlled Trial of Variable-Pressure Versus Fixed-Pressure Continuous Positive Airway Pressure (CPAP) Treatment for Patients with Obstructive Sleep Apnea/Hypopnea Syndrome (OSAHS) [J].
Vennelle, Marjorie ;
White, Sandra ;
Riha, Renata L. ;
Mackay, Tom W. ;
Engleman, Heather M. ;
Douglas, Neil J. .
SLEEP, 2010, 33 (02) :267-271
[33]   The effect of continuous positive airway pressure treatment on physical activity in patients with obstructive sleep apnoea: A randomised controlled trial [J].
West, Sophie D. ;
Kohler, Malcolm ;
Nicoll, Debby J. ;
Stradling, John R. .
SLEEP MEDICINE, 2009, 10 (09) :1056-1058
[34]   FIELD-TEST OF AROUSAL - A PORTABLE REACTION TIMER WITH DATA-STORAGE [J].
WILKINSON, RT ;
HOUGHTON, D .
HUMAN FACTORS, 1982, 24 (04) :487-493
[35]   Gender differences in the clinical manifestation of obstructive sleep apnea [J].
Ye, Lichuan ;
Pien, Grace W. ;
Weaver, Terri E. .
SLEEP MEDICINE, 2009, 10 (10) :1075-1084