Sensor and biosensor based on Prussian Blue modified gold and platinum screen printed electrodes

被引:115
作者
de Mattos, IL [1 ]
Gorton, L [1 ]
Ruzgas, T [1 ]
机构
[1] Lund Univ, Dept Analyt Chem, S-22100 Lund, Sweden
基金
巴西圣保罗研究基金会;
关键词
Prussian Blue; screen-printed electrodes; amperometric sensor; biosensor;
D O I
10.1016/S0956-5663(02)00185-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Gold (An) and platinum (Pt) screen-printed electrodes were modified with Prussian Blue (PB) for the development of amperometric sensors selective for hydrogen peroxide detection. The sensors exhibited sensitivities towards H2O2 equal to 2 A M-1 cm(-2) for An and 1 A M-1 cm(-2) for Pt electrodes. The sensors were also employed as the basis for construction of glucose biosensors through further modification with crystallised glucose oxidase immobilised in a Nafion membrane. In order to improve the operational stability of the modified electrodes a buffer solution containing tetrabutylammonium toluene-4-sulfonate was used. The long-term performance of the sensors and biosensors were evaluated by continuous monitoring of hydrogen peroxide and glucose solutions (50 muM and 1 mM, respectively) in the flow-injection mode for 10 h. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:193 / 200
页数:8
相关论文
共 37 条
[11]   CATALYSIS OF THE REDUCTION OF MOLECULAR-OXYGEN TO WATER AT PRUSSIAN BLUE MODIFIED ELECTRODES [J].
ITAYA, K ;
SHOJI, N ;
UCHIDA, I .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1984, 106 (12) :3423-3429
[12]   Novel hexacyanoferrate (III)-modified carbon electrodes: Application in miniaturized biosensors with potential for in vivo glucose sensing [J].
Jaffari, SA ;
Pickup, JC .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (11) :1167-1175
[13]   Novel hexacyanoferrate(III) modified graphite disc electrodes and their application in enzyme electrodes .1. [J].
Jaffari, SA ;
Turner, APF .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (01) :1-9
[14]   The electrocatalytic activity of Prussian blue in hydrogen peroxide reduction studied using a wall-jet electrode with continuous flow [J].
Karyakin, AA ;
Karyakina, EE ;
Gorton, L .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1998, 456 (1-2) :97-104
[15]   On the mechanism of H2O2 reduction at Prussian Blue modified electrodes [J].
Karyakin, AA ;
Karyakina, EE ;
Gorton, L .
ELECTROCHEMISTRY COMMUNICATIONS, 1999, 1 (02) :78-82
[16]  
Karyakin AA, 2001, ELECTROANAL, V13, P813, DOI 10.1002/1521-4109(200106)13:10<813::AID-ELAN813>3.0.CO
[17]  
2-Z
[18]   Improvement of electrochemical biosensors using enzyme immobilization from water-organic mixtures with a high content of organic solvent [J].
Karyakin, AA ;
Karyakina, EE ;
Gorton, L ;
Bobrova, OA ;
Lukachova, LV ;
Gladilin, AK ;
Levashov, AV .
ANALYTICAL CHEMISTRY, 1996, 68 (24) :4335-4341
[19]   A HIGH-SENSITIVE GLUCOSE AMPEROMETRIC BIOSENSOR BASED ON PRUSSIAN-BLUE MODIFIED ELECTRODES [J].
KARYAKIN, AA ;
GITELMACHER, OV ;
KARYAKINA, EE .
ANALYTICAL LETTERS, 1994, 27 (15) :2861-2869
[20]   Prussian Blue-based 'artificial peroxidase' as a transducer for hydrogen peroxide detection. Application to biosensors [J].
Karyakin, AA ;
Karyakina, EE .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 57 (1-3) :268-273