Dealing with image shifting in 3D ToF-SIMS depth profiles

被引:6
|
作者
Graham, Daniel J. [1 ]
Gamble, Lara J. [1 ]
机构
[1] Univ Washington, Dept Bioengn, NESAC BIO, Seattle, WA 98195 USA
基金
美国国家科学基金会;
关键词
ION MASS-SPECTROMETRY; ORGANIC MATERIALS; DAMAGE; BEAMS; MODEL;
D O I
10.1116/1.5041740
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The high sputter efficiency and low damage of gas cluster ion beams have enabled depth profiling to greater depths within organic samples using time-of-flight secondary ion mass spectrometry (ToF-SIMS). Due to the typically fixed geometry of the ion sources used in ToF-SIMS, as one digs into a surface, the position sampled by ion beams shifts laterally. This causes a lateral shift in the resulting images that can become quite significant when profiling down more than one micron. Here, three methods to compensate for this image shifting are presented in order to more accurately stack the images to present a 3D representation. These methods include (1) using software to correct the image shifts post-acquisition, (2) correcting the sample height during acquisition, and (3) adjusting the beam position during acquisition. The advantages and disadvantages of these methods are discussed. It was found that all three methods were successful in compensating for image shifting in ToF-SIMS depth profiles resulting in a more accurate display of the 3D data. Features from spherical objects that were ellipsoidal prior to shifting were seen to be spherical after correction. Software shifting is convenient as it can be applied after data acquisition. However, when using software shifting, one must take into account the scan size and the size of the features of interest as image shifts can be significant and can result in cropping of features of interest. For depth profiles deeper than a few microns, hardware methods should be used as they preserve features of interest within the field of view regardless of the profile depth. Software shifting can also be used to correct for small shifts not accounted for by hardware methods. A combination of hardware and software shift correction can enable correction for a wide range of samples and profiling depths. The scripts required for the software shifting demonstrated herein are provided along with tutorials in the supplementary material. Published by the AVS.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] TOF-SIMS depth profiling of deuterated polystyrene-block-poly(n-propyl methacrylate) diblock copolymer films
    Lee, Jihye
    Yoon, Donghwan
    Shin, Kwanwoo
    Kim, Kang-Jin
    Lee, Yeonhee
    SURFACE AND INTERFACE ANALYSIS, 2010, 42 (08) : 1409 - 1416
  • [42] Rapid multivariate analysis of 3D ToF-SIMS data: graphical processor units (GPUs) and low-discrepancy subsampling for large-scale principal component analysis
    Cumpson, Peter J.
    Fletcher, Ian W.
    Sano, Naoko
    Barlow, Anders J.
    SURFACE AND INTERFACE ANALYSIS, 2016, 48 (12) : 1328 - 1336
  • [43] Acquisition of artifact free alkali metal distributions in SiO2 by ToF-SIMS Cs+ depth profiling at low temperatures
    Leitzenberger, Michael
    Kuegler, Peter
    Krivec, Stefan
    Hutter, Herbert
    SURFACE AND INTERFACE ANALYSIS, 2021, 53 (08) : 675 - 680
  • [44] Investigation of Damage Mechanisms in PMMA during ToF-SIMS Depth Profiling with 5 and 8 keV SF5+ Primary Ions
    Mahoney, Christine M.
    Kushmerick, James G.
    Steffens, Kristen L.
    JOURNAL OF PHYSICAL CHEMISTRY C, 2010, 114 (34) : 14510 - 14519
  • [45] On the temperature dependence of Na migration in thin SiO2 films during ToF-SIMS O2+ depth profiling
    Krivec, Stefan
    Detzel, Thomas
    Buchmayr, Michael
    Hutter, Herbert
    APPLIED SURFACE SCIENCE, 2010, 257 (01) : 25 - 32
  • [46] Interaction of Human Plasma Proteins with Thin Gelatin-Based Hydrogel Films: A QCM-D and ToF-SIMS Study
    Schoenwaelder, Sina M. S.
    Bally, Florence
    Heinke, Lars
    Azucena, Carlos
    Bulut, Oezguel D.
    Heissler, Stefan
    Kirschhoefer, Frank
    Gebauer, Tim P.
    Neffe, Axel T.
    Lendlein, Andreas
    Brenner-Weiss, Gerald
    Lahann, Joerg
    Welle, Alexander
    Overhage, Joerg
    Woell, Christof
    BIOMACROMOLECULES, 2014, 15 (07) : 2398 - 2406
  • [47] High spatial resolution ToF-SIMS imaging and image analysis strategies to monitor and quantify early phase separation in amorphous solid dispersions
    Paladino, Eleonora
    Doerr, Frederik J. S.
    Bordos, Ecaterina
    Onyemelukwe, Iyke I.
    Lamprou, Dimitrios A.
    Florence, Alastair J.
    Gilmore, Ian S.
    Halbert, Gavin W.
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2022, 628
  • [48] Differences between Li, Na, and K migration in thin SiO2 films during ToF-SIMS O2+ depth profiling
    Krivec, Stefan
    Amsuess, Andreas
    Schwab, Stefan
    Hutter, Herbert
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2018, 36 (03):
  • [49] DEVELOPMENTS IN MOLECULAR SIMS DEPTH PROFILING AND 3D IMAGING OF BIOLOGICAL SYSTEMS USING POLYATOMIC PRIMARY IONS
    Fletcher, John S.
    Lockyer, Nicholas P.
    Vickerman, John C.
    MASS SPECTROMETRY REVIEWS, 2011, 30 (01) : 142 - 174
  • [50] ToF-SIMS Depth Profiling of PS-b-PMMA Block Copolymers Using Arn+, C60++, and Cs+ Sputtering Ions
    Terlier, T.
    Zappala, G.
    Marie, C.
    Leonard, D.
    Barnes, J. -P.
    Licciardello, A.
    ANALYTICAL CHEMISTRY, 2017, 89 (13) : 6984 - 6991