Influence of scan technique on intracoronary transluminal attenuation gradient in coronary CT angiography using 128-slice dual source CT: multi-beat versus one-beat scan

被引:4
|
作者
Kim, Hae Jin [1 ]
Kim, Sung Mok [1 ,2 ]
Choi, Jin-Ho [2 ,3 ]
Choe, Yeon Hyeon [1 ,2 ]
机构
[1] Sungkyunkwan Univ, Dept Radiol, Samsung Med Ctr, Sch Med, Seoul, South Korea
[2] Sungkyunkwan Univ, Heart Vasc & Stroke Inst, Cardiovasc Imaging Ctr, Samsung Med Ctr,Sch Med, Seoul, South Korea
[3] Sungkyunkwan Univ, Div Cardiol, Dept Med, Samsung Med Ctr,Sch Med, Seoul, South Korea
关键词
Transluminal attenuation gradient; Corrected contrast opacification; Non-invasive hemodynamics; Coronary computed tomography angiography; Temporal uniformity; FRACTIONAL FLOW RESERVE; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; DIAGNOSTIC PERFORMANCE; ARTERY STENOSIS; MYOCARDIAL SEGMENTATION; ADDITIONAL VALUE; DISEASE; QUANTIFICATION; METAANALYSIS; SEVERITY;
D O I
10.1007/s10554-017-1078-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of our study was to investigate the impact of temporal uniformity and adjustment by the contrast opacification enhancement in the aorta on the performance of transluminal attenuation gradient (TAG) for obstructive coronary artery disease. A total of 274 coronary arteries from 94 patients who underwent both multi- and single-beat scan using 128-slice scanner at the same time were enrolled. TAG and corrected coronary opacification (CCO) of both scan technique were compared against obstructive coronary arteries defined by diameter stenosis >= 50%. In per-vessel analysis, both TAG and CCO were slight but significantly different between multi- and single-beat scan in overall (-13.3 vs. -14.3 HU/10 mm; 0.31 vs. 0.38; p < 0.05, all). However, the difference was evident only in right coronary artery (p < 0.05) but not in left coronary arteries (p = NS). Correlation coefficient value are more than 0.8 for all coronary arteries (0.84) and each of the three vessels (RCA: 0.87, LAD: 0.84, LCX: 0.81) in TAG in single-beat versus multi-beat scans (p < 0.0001). Radiation exposure was significantly lower in single-beat scan compared to multi-beat scan (0.9 vs. 3.7 mSv, p < 0.001). TAGs of multi- and single beat scans well correlated each other in all coronary arteries and were not affected by temporal non-uniformity.
引用
收藏
页码:937 / 946
页数:10
相关论文
共 9 条
  • [1] Influence of scan technique on intracoronary transluminal attenuation gradient in coronary CT angiography using 128-slice dual source CT: multi-beat versus one-beat scan
    Hae Jin Kim
    Sung Mok Kim
    Jin-Ho Choi
    Yeon Hyeon Choe
    The International Journal of Cardiovascular Imaging, 2017, 33 : 937 - 946
  • [2] Transluminal attenuation-gradient coronary CT angiography on a 320-MDCT volume scanner: Effect of scan timing, coronary artery stenosis, and cardiac output using a contrast medium flow phantom
    Funama, Yoshinori
    Utsunomiya, Daisuke
    Oda, Seitaro
    Shimonobo, Toshiaki
    Nakaura, Takeshi
    Mukunoki, Toshifumi
    Kidoh, Masafumi
    Yuki, Hideaki
    Yamashita, Yasuyuki
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (11): : 1415 - 1421
  • [3] Quantification and Limitation of CT Coronary Angiography Using 128-Slice Dual-Source CT at High Heart Rates: A Simulation Study
    Zhao, Lei
    Liu, Aishi
    Guo, Youmin
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (06) : 1201 - 1206
  • [4] Ultra-low dose one-step CT angiography for coronary, carotid and cerebral arteries using 128-slice dual-source CT: A feasibility study
    Zhao, Lei
    Bao, Jiaqi
    Guo, Youmin
    Li, Jianbo
    Yang, Xiaoguang
    Lv, Tiegang
    Hao, Fen'e
    Wang, Zefeng
    Yang, Zhenxing
    Liu, Aishi
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2019, 17 (05) : 4167 - 4175
  • [5] Transluminal attenuation gradient and corrected models in coronary CT angiography for determining stenosis severity: a primary study using dual-source CT
    Peng, K.
    Xu, N.
    Zhang, L.
    Xiao, F.
    Indima, N.
    Zhang, J.
    Shen, Y.
    Peng, W.
    Tang, G.
    CLINICAL RADIOLOGY, 2017, 72 (06) : 508 - 516
  • [6] Adenosine-stress low-dose single-scan CT myocardial perfusion imaging using a 128-slice dual-source CT: a comparison with fractional flow reserve
    Choo, Ki Seok
    Hwangbo, Lee
    Kim, June Hong
    Park, Yong Hyun
    Kim, Jeong Su
    Kim, Jun
    Chun, Kook Jin
    Jeong, Dong Wook
    Lim, Soo Jin
    ACTA RADIOLOGICA, 2013, 54 (04) : 389 - 395
  • [7] Ultra-low-dose CT coronary angiography using 128-slice dual source CT with low concentration contrast agent: initial experience
    Zhao, Lei
    Liu, Aishi
    Guo, Youmin
    JAPANESE JOURNAL OF RADIOLOGY, 2017, 35 (12) : 724 - 732
  • [8] Low-Concentration Contrast Medium for 128-Slice Dual-Source CT Coronary Angiography at a Very Low Radiation Dose Using Prospectively ECG-Triggered High-Pitch Spiral Acquisition
    Zheng, Minwen
    Wu, Yongjie
    Wei, Mengqi
    Liu, Ying
    Zhao, Hongliang
    Li, Jian
    ACADEMIC RADIOLOGY, 2015, 22 (02) : 195 - 202
  • [9] Low-dose coronary-CT angiography using step and shoot at any heart rate: comparison of image quality at systole for high heart rate and diastole for low heart rate with a 128-slice dual-source machine
    Paul, Jean-Francois
    Amato, Aude
    Rohnean, Adela
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (03) : 651 - 657