Effects of pilot holes on longitudinal miniscrew stability and bony adaptation

被引:8
作者
Carney, Lauren Ohlenforst
Campbell, Phillip M. [1 ]
Spears, Robert [2 ]
Ceen, Richard F. [1 ]
Melo, Ana Claudia [3 ]
Buschang, Peter H. [1 ]
机构
[1] Texas A&M Univ, Baylor Coll Dent, Dept Orthodont, Dallas, TX 75246 USA
[2] Texas A&M Univ, Baylor Coll Dent, Dept Biomed Sci, Dallas, TX 75246 USA
[3] Inst Amer Pesquisa & Ensino Odontolog, Curitiba, Parana, Brazil
关键词
RESONANCE FREQUENCY-ANALYSIS; ORTHODONTIC MINI-IMPLANTS; DAMPING CAPACITY ASSESSMENT; DRILL FREE SCREWS; CORTICAL BONE; IN-VIVO; ENDOSSEOUS IMPLANTS; TITANIUM IMPLANTS; INSERTION TORQUE; PART I;
D O I
10.1016/j.ajodo.2014.07.017
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purposes of this study were to longitudinally evaluate the effects of pilot holes on miniscrew implant (MSI) stability and to determine whether the effects can be attributed to the quality or the quantity of bone surrounding the MSI. Methods: Using a randomized split-mouth design in 6 skeletally mature female foxhound-mix dogs, 17 MSIs (1.6 mm outer diameter) placed with pilot holes (1.1 mm) were compared with 17 identical MSIs placed without pilot holes. Implant stability quotient measurements of MSI stability were taken weekly for 7 weeks. Using microcomputed tomography with an isotropic resolution of 6 mm, bone volume fractions were measured for 3 layers of bone (6-24, 24-42, and 42-60 mm) surrounding the MSIs. Results: At placement, the MSIs with pilot holes showed significantly (P < 0.05) higher implant stability quotient values than did the MSIs placed without pilot holes (48.3 vs 47.5). Over time, the implant stability quotient values decreased significantly more for the MSIs placed with pilot holes than for those placed without pilot holes. After 7 weeks, the most coronal aspect of the 6- to 24-mm layer of cortical bone and the most coronal aspects of all 3 layers of trabecular bone showed significantly larger bone volume fractions for the MSIs placed without pilot holes than for those placed with pilot holes. Conclusions: MSIs placed with pilot holes show greater primary stability, but greater decreases in stability over time, due primarily to having less trabecular bone surrounding them.
引用
收藏
页码:554 / 564
页数:11
相关论文
共 82 条
[11]   Intrusion of multiradicular teeth and related root resorption with mini-screw implant anchorage: A radiographic evaluation [J].
Carrillo, Roberto ;
Rossouw, P. Emile ;
Franco, Pedro F. ;
Opperman, Lynne A. ;
Buschang, Peter H. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 132 (05) :647-655
[12]   Segmental intrusion with mini-screw implant anchorage: A radiographic evaluation [J].
Carrillo, Roberto ;
Buschang, Peter H. ;
Opperman, Lynne A. ;
Franco, Pedro F. ;
Rossouw, P. Emile .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 132 (05) :576.e1-576.e6
[13]   Primary stability and histomorphometric bone-implant contact of self-drilling and self-tapping orthodontic microimplants [J].
Cehreli, Secil ;
Arman-Ozcirpici, Ayca .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2012, 141 (02) :187-195
[14]   Heat production by 3 implant drill systems after repeated drilling and sterilization [J].
Chacon, GE ;
Bower, DL ;
Larsen, PE ;
McGlumphy, EA ;
Beck, FM .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 64 (02) :265-269
[15]   Influence of surface characteristics on survival rates of mini-implants [J].
Chaddad, Karim ;
Ferreira, Andre F. H. ;
Geurs, Nico ;
Reddy, Michael S. .
ANGLE ORTHODONTIST, 2008, 78 (01) :107-113
[16]   Biomechanical and histological comparison of self-drilling and self-tapping orthodontic microimplants in dogs [J].
Chen, Yan ;
Shin, Hong-In ;
Kyung, Hee-Moon .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 133 (01) :44-50
[17]  
Cheng SJ, 2004, INT J ORAL MAX IMPL, V19, P100
[18]   Normal Bone Anatomy and Physiology [J].
Clarke, Bart .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2008, 3 :S131-S139
[19]  
Cochran DL, 1998, J BIOMED MATER RES, V40, P1, DOI 10.1002/(SICI)1097-4636(199804)40:1<1::AID-JBM1>3.0.CO
[20]  
2-Q