Effects of pilot holes on longitudinal miniscrew stability and bony adaptation

被引:8
作者
Carney, Lauren Ohlenforst
Campbell, Phillip M. [1 ]
Spears, Robert [2 ]
Ceen, Richard F. [1 ]
Melo, Ana Claudia [3 ]
Buschang, Peter H. [1 ]
机构
[1] Texas A&M Univ, Baylor Coll Dent, Dept Orthodont, Dallas, TX 75246 USA
[2] Texas A&M Univ, Baylor Coll Dent, Dept Biomed Sci, Dallas, TX 75246 USA
[3] Inst Amer Pesquisa & Ensino Odontolog, Curitiba, Parana, Brazil
关键词
RESONANCE FREQUENCY-ANALYSIS; ORTHODONTIC MINI-IMPLANTS; DAMPING CAPACITY ASSESSMENT; DRILL FREE SCREWS; CORTICAL BONE; IN-VIVO; ENDOSSEOUS IMPLANTS; TITANIUM IMPLANTS; INSERTION TORQUE; PART I;
D O I
10.1016/j.ajodo.2014.07.017
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purposes of this study were to longitudinally evaluate the effects of pilot holes on miniscrew implant (MSI) stability and to determine whether the effects can be attributed to the quality or the quantity of bone surrounding the MSI. Methods: Using a randomized split-mouth design in 6 skeletally mature female foxhound-mix dogs, 17 MSIs (1.6 mm outer diameter) placed with pilot holes (1.1 mm) were compared with 17 identical MSIs placed without pilot holes. Implant stability quotient measurements of MSI stability were taken weekly for 7 weeks. Using microcomputed tomography with an isotropic resolution of 6 mm, bone volume fractions were measured for 3 layers of bone (6-24, 24-42, and 42-60 mm) surrounding the MSIs. Results: At placement, the MSIs with pilot holes showed significantly (P < 0.05) higher implant stability quotient values than did the MSIs placed without pilot holes (48.3 vs 47.5). Over time, the implant stability quotient values decreased significantly more for the MSIs placed with pilot holes than for those placed without pilot holes. After 7 weeks, the most coronal aspect of the 6- to 24-mm layer of cortical bone and the most coronal aspects of all 3 layers of trabecular bone showed significantly larger bone volume fractions for the MSIs placed without pilot holes than for those placed with pilot holes. Conclusions: MSIs placed with pilot holes show greater primary stability, but greater decreases in stability over time, due primarily to having less trabecular bone surrounding them.
引用
收藏
页码:554 / 564
页数:11
相关论文
共 82 条
[1]   Interspecies differences in bone composition, density, and quality:: Potential implications for in vivo bone research [J].
Aerssens, J ;
Boonen, S ;
Lowet, G ;
Dequeker, J .
ENDOCRINOLOGY, 1998, 139 (02) :663-670
[2]  
Antoszewska J, 2009, AM J ORTHOD DENTOFAC, V136, DOI [10.1016/j.ajodo.2009.03.031, 10.1016/j.ajodo.2009.03.032]
[3]  
Bakaeen L, 2009, INT J PERIODONT REST, V29, P297
[4]  
Balshi SF, 2005, INT J ORAL MAX IMPL, V20, P584
[5]  
Barewal RM, 2003, INT J ORAL MAX IMPL, V18, P641
[6]   De novo alveolar bone formation adjacent to endosseous implants -: A model study in the dog [J].
Berglundh, T ;
Abrahamsson, I ;
Lang, NP ;
Lindhe, J .
CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (03) :251-262
[7]  
BOUCHER HH, 1959, J BONE JOINT SURG BR, V41, P248
[8]  
BRUNSKI J B, 1992, Clinical Materials, V10, P153, DOI 10.1016/0267-6605(92)90049-Y
[9]  
Buschang PH, 2011, MONOGRAPH U MICHIGAN, V48
[10]  
Butz F, 2006, INT J ORAL MAX IMPL, V21, P687