Precision-guided surgical navigation system using laser guidance and 3D autostereoscopic image overlay

被引:24
作者
Liao, Hongen [1 ,2 ]
Ishihara, Hirotaka [3 ]
Tran, Huy Hoang [3 ]
Masamune, Ken [3 ]
Sakuma, Ichiro [2 ,4 ]
Dohi, Takeyoshi [3 ]
机构
[1] Univ Tokyo, Grad Sch Engn, Dept Bioengn, Bunkyo Ku, Tokyo 1138656, Japan
[2] Univ Tokyo, Translat Syst Biol & Med Initiat, Bunkyo Ku, Tokyo 1138656, Japan
[3] Univ Tokyo, Grad Sch Informat Sci & Technol, Dept Mechanoinformat, Bunkyo Ku, Tokyo 1138656, Japan
[4] Univ Tokyo, Grad Sch Engn, Dept Precis Engn, Bunkyo Ku, Tokyo 1138656, Japan
关键词
Surgical navigation; Laser guidance; Image overlay; Autostereoscopic image; Minimally invasive surgery; EYE-HAND COORDINATION; INTEGRAL VIDEOGRAPHY; SURGERY;
D O I
10.1016/j.compmedimag.2009.07.003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper describes a precision-guided surgical navigation system for minimally invasive surgery. The system combines a laser guidance technique with a three-dimensional (3D) autostereoscopic image overlay technique. Images of surgical anatomic structures superimposed onto the patient are created by employing an animated imaging method called integral videography (IV), which can display geometrically accurate 3D autostereoscopic images and reproduce motion parallax without the need for special viewing or tracking devices. To improve the placement accuracy of surgical instruments, we integrated an image overlay system with a laser guidance system for alignment of the surgical instrument and better visualization of patient's internal structure. We fabricated a laser guidance device and mounted it on an IV image overlay device. Experimental evaluations showed that the system could guide a linear surgical instrument toward a target with an average error of 2.48 mm and standard deviation of 1.76 mm. Further improvement to the design of the laser guidance device and the patient-image registration procedure of the IV image overlay will make this system practical; its use would increase surgical accuracy and reduce invasiveness. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:46 / 54
页数:9
相关论文
共 18 条
  • [1] Breedveld P, 2001, MINIM INVASIV THER, V10, P155
  • [2] Theoretical background and conceptual solution for depth perception and eye-hand coordination problems in laparoscopic surgery
    Breedveld, P
    Stassen, HG
    Meijer, DW
    Stassen, LPS
    [J]. MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 1999, 8 (04) : 227 - 234
  • [3] Design and evaluation of a system for microscope-assisted guided interventions (MAGI)
    Edwards, PJ
    King, AP
    Maurer, CR
    de Cunha, DA
    Hawkes, DJ
    Hill, DLG
    Gaston, RP
    Fenlon, MR
    Jusczyzck, A
    Strong, AJ
    Chandler, CL
    Gleeson, MJ
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (11) : 1082 - 1093
  • [4] Image overlay guidance for needle insertion in CT scanner
    Fichtinger, G
    Deguet, A
    Masamune, K
    Balogh, E
    Fischer, GS
    Mathieu, H
    Taylor, RH
    Zinreich, SJ
    Fayad, LM
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (08) : 1415 - 1424
  • [5] Glossop N, 2003, LECT NOTES COMPUT SC, V2879, P239
  • [6] Surgical navigation by auto stereo scopic image overlay of integral videography
    Liao, H
    Hata, N
    Nakajima, S
    Iwahara, M
    Sakuma, I
    Dohi, T
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2004, 8 (02): : 114 - 121
  • [7] High-quality integral videography using a multiprojector
    Liao, HG
    Iwahara, M
    Hata, N
    Dohi, T
    [J]. OPTICS EXPRESS, 2004, 12 (06): : 1067 - 1076
  • [8] Liao H, 2006, LECT NOTES COMPUT SC, V4091, P187
  • [9] Lippmann G., 1908, J.de Phys, V7, P821, DOI DOI 10.1051/JPHYSTAP:019080070082100
  • [10] LASER GUIDANCE-SYSTEM FOR CT-GUIDED PROCEDURES
    MIAUX, Y
    GUERMAZI, A
    GOSSOT, D
    BOURRIER, P
    ANGOULVANT, D
    KHAIROUNE, A
    TURKI, C
    BOUCHE, E
    [J]. RADIOLOGY, 1995, 194 (01) : 282 - 284