Fast acquisition cone-beam computed tomography: initial experience with a 10 s protocol

被引:9
作者
Srinivasan, Visish M. [1 ]
Chintalapani, Gouthami [2 ]
Camstra, Kevin Matthew [1 ]
Effendi, Sabih T. [1 ]
Cherian, Jacob [1 ]
Johnson, Jeremiah N. [1 ]
Chen, Stephen R. [3 ]
Kan, Peter [1 ]
机构
[1] Baylor Coll Med, Dept Neurosurg, Houston, TX 77030 USA
[2] Siemens Med Imaging, Hoffman Estates, IL USA
[3] Baylor Coll Med, Dept Radiol, Houston, TX 77030 USA
关键词
angiography; flow diverter; stent; CT; APPOSITION;
D O I
10.1136/neurintsurg-2017-013475
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Background Cone-beam computed tomography (CBCT) facilitates the acquisition of cross-sectional imaging in angiography suites using a rotational C-arm and digital flat panel detectors. The applications are numerous, including evaluation of implanted devices and localization of cerebrovascular lesions. We present and validate the clinical utility of an alternative fast CBCT acquisition protocol in the context of neurovascular device imaging. Methods Contrast-enhanced (CE)-CBCT images were acquired using a new 10s protocol in a phantom head model, swine model, and in patients. The acquisition parameters of both the 10 s and 20s protocols were exactly the same, except for fewer projections (250 projections in 10s vs 500 projections in 20s), resulting in reduced scan time. Image quality was measured quantitatively in a controlled phantom study and qualitatively by blinded reviewers. The latter was performed to assess the image quality of the 10s protocol pertinent to the device visibility and its apposition to the parent artery. Results 10s CBCT images were comparable to 20s CBCT in both phantom and animal studies. Of the 25 patient images, the reviewers agreed that they were able to discern the flow diverter struts and assess the apposition in all images. The overall rating for all 10s images was 4.28 on a 5-point scale. No images were rated as less than 3, which was the average diagnostic quality. The ratings were concordant across three blinded reviewers (=0.411). Additionally, contrast and spatial resolution between 10s and 20s images were similar in non-human models. Conclusions CBCT images of neurovascular devices can be obtained successfully using a 10s acquisition protocol. In addition, the 10s protocol offers faster acquisition, thus allowing its use in awake patients and with an added advantage of lower radiation and contrast dose.
引用
收藏
页码:916 / 920
页数:5
相关论文
共 10 条
  • [1] Cone Beam Computed Tomography in the Neurointerventional Room: Beyond Vessels
    Ansari, Sameer A.
    Aoun, Salah G.
    Bendok, Bernard R.
    [J]. WORLD NEUROSURGERY, 2012, 77 (5-6) : 659 - 661
  • [2] DynaCT imaging for intraprocedural evaluation of flow-diverting stent apposition during endovascular treatment of intracranial aneurysms
    Ding, Dale
    Starke, Robert M.
    Durst, Christopher R.
    Gaughen, John R., Jr.
    Evans, Avery J.
    Jensen, Mary E.
    Liu, Kenneth C.
    [J]. JOURNAL OF CLINICAL NEUROSCIENCE, 2014, 21 (11) : 1981 - 1983
  • [3] Adjunctive value of intra-arterial cone beam CT angiography relative to DSA in the evaluation of cranial and spinal arteriovenous fistulas
    Honarmand, Amir R.
    Gemmete, Joseph J.
    Hurley, Michael C.
    Shalbani, Ali
    Chaudhary, Neeraj
    Pandey, Aditya S.
    Bendok, Bernard R.
    Ansari, Sameer A.
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2015, 7 (07) : 517 - 523
  • [4] C-arm flat detector computed tomography: the technique and its applications in interventional neuro-radiology
    Kamran, Mudassar
    Nagaraja, Sanjoy
    Byrne, James V.
    [J]. NEURORADIOLOGY, 2010, 52 (04) : 319 - 327
  • [5] MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA
    LANDIS, JR
    KOCH, GG
    [J]. BIOMETRICS, 1977, 33 (01) : 159 - 174
  • [6] C-Arm Conebeam CT Perfusion Imaging in the Angiographic Suite: A Comparison with Multidetector CT Perfusion Imaging
    Niu, K.
    Yang, P.
    Wu, Y.
    Struffert, T.
    Doerfler, A.
    Schafer, S.
    Royalty, K.
    Strother, C.
    Chen, G. -H.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (07) : 1303 - 1309
  • [7] Contrast-Enhanced Angiographic Cone-Beam CT of Cerebrovascular Stents: Experimental Optimization and Clinical Application
    Patel, N. V.
    Gounis, M. J.
    Wakhloo, A. K.
    Noordhoek, N.
    Blijd, J.
    Babic, D.
    Takhtani, D.
    Lee, S. -K.
    Norbash, A.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (01) : 137 - 144
  • [8] Development of a recalcitrant, large clot burden, bifurcation occlusion model for mechanical thrombectomy
    Srinivasan, Visish M.
    Chen, Stephen R.
    Camstra, Kevin M.
    Chintalapani, Gouthami
    Kan, Peter
    [J]. NEUROSURGICAL FOCUS, 2017, 42 (04)
  • [9] Cone-beam CT angiography (Dyna CT) for intraoperative localization of cerebral arteriovenous malformations
    Srinivasan, Visish M.
    Schafer, Sebastian
    Ghali, Michael G. Z.
    Arthur, Adam
    Duckworth, Edward A. M.
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (01) : 69 - 74
  • [10] Grading of Regional Apposition after Flow-Diverter Treatment (GRAFT): a comparative evaluation of VasoCT and intravascular OCT
    van der Marel, Kajo
    Gounis, Matthew J.
    Weaver, John P.
    de Korte, Antonius M.
    King, Robert M.
    Arends, Jennifer M.
    Brooks, Olivia W.
    Wakhloo, Ajay K.
    Puri, Ajit S.
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (08) : 847 - 852