Inflationary oscillometric blood pressure monitoring: validation of the OMRON-MIT

被引:22
作者
Golara, M [1 ]
Jones, C [1 ]
Randhawa, M [1 ]
Shennan, AH [1 ]
机构
[1] St Thomas Hosp, Maternal & Foetal Res Unit, GKT Sch Med, London SE1 7EH, England
关键词
blood pressure; measurement; validation; oscillometric;
D O I
10.1097/00126097-200212000-00006
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background To evaluate the accuracy of the OMRON-MIT, (an automated inflationary oscillometric blood pressure monitoring device) for use in the general population by direct comparison to standard auscultatory mercury sphygmomanometry. Design Two trained, blinded observers taking simultaneous blood pressure measurements alternating between a mercury sphygmomanometer and the OMRON-MIT. Methods The evaluation was carried out according to the revised British Hypertension Society protocol. The validation data was also classified by the American Association for the Advancement of Medical Instrumentation (AAMI). Results The OMRON-MIT device achieved a BHS grade A for both systolic blood pressure (SBP) and diastolic blood pressure (DBP). It also met the criteria for the AAMI protocol, the mean difference between the MIT and standard was -2.0 +/- 7 mmHg for SBP and -2.0 +/- 6 mmHg for DBP. Conclusions Inflationary oscillometry is a valid technique for the measurement of blood pressure. The OMRON-MIT, which uses this technique, is accurate and can be recommended for clinical use in the adult population. (C) 2002 Lippincott Williams Wilkins.
引用
收藏
页码:325 / 328
页数:4
相关论文
共 7 条
[1]  
Association for the Advancement of Medical Instrumentation, 1993, AM NAT STAND EL AUT
[2]   ABC of hypertension - Blood pressure measurement Part II - Conventional sphygmomanometry: technique of auscultatory blood pressure measurement [J].
Beevers, G ;
Lip, GYH ;
O'Brien, E .
BMJ-BRITISH MEDICAL JOURNAL, 2001, 322 (7293) :1043-1047
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]  
Golara M, 2002, BJOG-INT J OBSTET GY, V109, P1143
[5]   Blood pressure measuring devices: recommendations of the European Society of Hypertension [J].
O'Brien, E ;
Waeber, B ;
Parati, G ;
Staessen, J ;
Myers, MG .
BMJ-BRITISH MEDICAL JOURNAL, 2001, 322 (7285) :531-536
[6]   THE BRITISH-HYPERTENSION-SOCIETY PROTOCOL FOR THE EVALUATION OF AUTOMATED AND SEMIAUTOMATED BLOOD-PRESSURE MEASURING DEVICES WITH SPECIAL REFERENCE TO AMBULATORY SYSTEMS [J].
OBRIEN, E ;
PETRIE, J ;
LITTLER, W ;
DESWIET, M ;
PADFIELD, PL ;
OMALLEY, K ;
JAMIESON, M ;
ALTMAN, D ;
BLAND, M ;
ATKINS, N .
JOURNAL OF HYPERTENSION, 1990, 8 (07) :607-619
[7]  
OBrien E, 1995, J HUM HYPERTENS, V9, P933