Exergy analysis and entropy generation of a reciprocating compressor applied in CNG stations carried out on the basis models of ideal and real gas

被引:28
作者
Niazmand, Amir [1 ]
Farzaneh-Gord, Mahmood [1 ]
Deymi-Dashtebayaz, Mandi [2 ]
机构
[1] Shahrood Univ Technol, Fac Mech Engn, Shahrood, Iran
[2] Hakim Sabzevari Univ, Mech Engn, Sabzevar, Iran
关键词
Natural gas; AGA8; equation; Reciprocating compressor; Design parameters; Second law of thermodynamic; Entropy generation; Exergy efficiency; THERMODYNAMIC ANALYSIS; PERFORMANCE ANALYSIS; CAPACITY;
D O I
10.1016/j.applthermaleng.2017.06.035
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this work, a numerical analysis for observing the proficiency of reciprocating compressors used in CNG (Compressed Natural Gas) stations is studied thermodynamically for ideal model and real one. AGA8 state equation is intended for modeling real gas. The analysis is carried out on the basis of the entropy concept. To investigate effects of important design factors on entropy generation, isentropic and exergy efficiencies, a numerical method is developed. The considered design factors are clearance, angular speed, pressure ratio and input and output valve areas. In this analysis, the compressor cylinder is presumed as control volume, and methane is also chosen as the natural gas and modeled as both an ideal gas and real one. The results highlight that with increasing angular speed, entropy generating increases and consequently exergy and isentropic efficiencies decrease, while increase in clearance acquires the inverse results. Furthermore, it will reach to higher efficiency, if input valve area is considered more than output valve area. For instance, with choosing a suitable proportion, efficiency can increase as much as 6.47%. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1279 / 1291
页数:13
相关论文
共 34 条
[1]  
[Anonymous], 1996, ENTROPY GENERATION M
[2]  
[Anonymous], 1992, 8 TRANSM MEAS COMM
[3]  
[Anonymous], 1972, PROC PURDUE COMPRESS
[4]   Refrigeration plant exergetic analysis varying the compressor capacity [J].
Aprea, C ;
de Rossi, F ;
Greco, A ;
Renno, C .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2003, 27 (07) :653-669
[5]   Determination of the compressor optimal working conditions [J].
Aprea, C. ;
Mastrullo, R. ;
Renno, C. .
APPLIED THERMAL ENGINEERING, 2009, 29 (10) :1991-1997
[6]   Experimental model of a variable capacity compressor [J].
Aprea, C. ;
Renno, C. .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2009, 33 (01) :29-37
[7]  
Bejan A., 1982, Adv. Heat Transfer, V15, P158, DOI DOI 10.1016/S0065-2717(08)70172-2
[8]  
Bin T., 2013, APPL THERM ENG, V54, P380
[9]  
BRABLIK J, 1972, P PURD COMPR TECHN C, P188
[10]   Dynamic simulation of reciprocating refrigeration compressors and experimental validation [J].
Castaing-Lasvignottes, Jean ;
Gibout, Stephane .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2010, 33 (02) :381-389