New polymer tensiometers: Measuring matric pressures down to the wilting point

被引:42
作者
Bakker, Gerben
van der Ploeg, Martine J.
de Rooij, Gerrit H.
Hoogendam, Cornelis W.
Gooren, Hermanus P. A.
Huiskes, Cindy
Koopal, Luuk K.
Kruidhof, Henk
机构
[1] Univ Wageningen & Res Ctr, ALTERRA, NL-6708 PB Wageningen, Netherlands
[2] Univ Wageningen & Res Ctr, Dep Environm Sci, NL-6708 PB Wageningen, Netherlands
[3] Univ Wageningen & Res Ctr, Ground Water Management Grp, NL-6708 PB Wageningen, Netherlands
[4] Univ Wageningen & Res Ctr, Lab Phys Chem & Colloid Sci, NL-6703 HB Wageningen, Netherlands
[5] Univ Twente, Fac Sci & Technol, NL-7500 AE Enschede, Netherlands
关键词
D O I
10.2136/vzj2006.0110
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Tensiometers are commonly used for measuring soil water matric pressures. Unfortunately, the water-filled reservoir of conventional tensiometers limits their applicability to soil water matric pressures above approximately -0.085 MPa. Tensiometers filled with a polymer solution instead of water are able to measure a larger range of soil water matric pressures. We designed and constructed six prototype polymer tensiometers ( previously called osmotic tensiometers) consisting of a wide-range pressure transducer with a temperature sensor, a stainless steel casing, and a ceramic plate with a membrane preventing polymer leakage. A polymer chamber ( 0.1-2.2 cm(3)) was located between the pressure transducer and the plate. We tested the polymer tensiometers for long-term operation, the effects of temperature, response times, and performance in a repacked sandy loam under laboratory conditions. Several months of continuous operation caused a gradual drop in the osmotic pressure, for which we developed a suitable correction. The osmotic potential of polymer solutions is temperature dependent, and requires calibration before installation. The response times to sudden and gradual changes in ambient temperature were found to be affected by polymer chamber height and polymer type. Practically useful response times (<0.2 d) are feasible, particularly for chambers shorter than 0.20 cm. We demonstrated the ability of the instrument to measure the range of soil water pressures in which plant roots are able to take up water ( from 0 to -1.6 MPa), to regain pressure without user interference and to function properly for time periods of up to 1 yr.
引用
收藏
页码:196 / 202
页数:7
相关论文
共 26 条
  • [1] Comparison of four methods for measuring total suction
    Agus, SS
    Schanz, T
    [J]. VADOSE ZONE JOURNAL, 2005, 4 (04) : 1087 - 1095
  • [2] REJECTION OF MINERAL SALTS ON A GAMMA-ALUMINA NANOFILTRATION MEMBRANE APPLICATION TO ENVIRONMENTAL PROCESS
    ALAMIYOUNSSI, S
    LARBOT, A
    PERSIN, M
    SARRAZIN, J
    COT, L
    [J]. JOURNAL OF MEMBRANE SCIENCE, 1995, 102 : 123 - 129
  • [3] Andraski B. J., 2002, METHODS SOIL ANAL 4, P609, DOI DOI 10.2136/SSSABOOKSER5.4.C22
  • [4] A prototype osmotic tensiometer with polymeric gel grains
    Biesheuvel, PM
    van Loon, AP
    Raangs, R
    Verweij, H
    Dirksen, C
    [J]. EUROPEAN JOURNAL OF SOIL SCIENCE, 2000, 51 (02) : 355 - 364
  • [5] Response of the osmotic tensiometer to varying temperatures: Modeling and experimental validation
    Biesheuvel, PM
    Raangs, R
    Verweij, H
    [J]. SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 1999, 63 (06) : 1571 - 1579
  • [6] Bocking K.A., 1979, Geotechnical Testing Journal, V2, P3
  • [7] CASSEL DK, 1986, SSSA BOOK SER, V5, P563
  • [8] Degradation on polyacrylamides. part I. Linear polyacrylamide
    Caulfield, MJ
    Hao, XJ
    Qiao, GG
    Solomon, DH
    [J]. POLYMER, 2003, 44 (05) : 1331 - 1337
  • [9] APPLICATION OF THE POTENTIAL CONCEPT TO SOIL-WATER EQUILIBRIUM AND TRANSPORT
    COREY, AT
    KLUTE, A
    [J]. SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 1985, 49 (01) : 3 - 11
  • [10] Dane J.H., 2002, METHODS SOIL ANAL 4, P671, DOI DOI 10.2136/SSSABOOKSER5.4.C24